ICP DAS data logger module that records PM1, PM2.5 and PM10 particles, temperature, humidity and dew point, with RS-485 and Ethernet PoE interfaces.
Operating Temperature0 ~ 50°C
ConsumptionNon-PoE: 2.3 W (Max.) PoE: 2.5 W (Max.)
Real-time clockYes
Storage Temperature-30 ~ +75°C
Dimensions (mm)Ø 150 x 53 (Ø x H)
CA-RJ45-04RJ45 Cable, Male-Female, 30 cm (90º)
Product overview
CL-220-E data logger. The ICP DAS CL-220-E module records PM1, PM2.5 and PM10 particles, temperature, humidity and dew point, with date and time stamps on each measurement. It is an air quality acquisition module intended for environmental monitoring.
Main characteristics. The module stores up to 450,000 records with date and time, thanks to its real-time clock. Particles are measured in sizes of 0.3 µm, 0.5 µm, 1 µm, 2.5 µm, 5 µm and 10 µm. A relay output of 1 x Form A, SPST, 30 VDC at 16 A or 250 VAC at 16 A allows alarm triggering or control of an indoor air quality device.
Interfaces and connectivity. The module provides one RS-485 port and one Ethernet port, and supports DCON and Modbus RTU over RS-485, as well as Modbus TCP and MQTT over Ethernet. A web-based configuration interface, a software utility, and iOS and Android apps are included.
Power and environment. The module is powered by PoE or from a terminal block at +12 to +48 VDC. Consumption is 2.3 W maximum without PoE and 2.5 W maximum with PoE. It operates between 0 and 50 °C and stores between -30 and +75 °C, for humidity of 10 to 90% RH non-condensing. Its ingress protection rating is IP20. Dimensions are Ø 150 x 53 mm, with ceiling or wall mounting.
Typical uses. The RS-485 port and Modbus RTU support allow connection to PLCs and supervisory systems. Modbus TCP and MQTT support enables integration into Ethernet networks and IoT architectures.
Compatible accessories. The EWB-C150 external wall box and the FLT-C002 replaceable filter patch are available for this series.
PM1/PM2.5/PM10/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-221-E CR
PM1/PM2.5/PM10/CO/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-222-E CR
PM1/PM2.5/PM10/CO /Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS) 2
CL-223-E CR
PM1/PM2.5/PM10/CO/CO /Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS) 2
CL-224-E CR
PM1/PM2.5/PM10/HCHO/TVOC/Temperature/Humidity/Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-225-E CR
PM1/PM2.5/PM10/NH /Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS) 3
CL-226-E CR
PM1/PM2.5/PM10/H S/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS) 2
CL-227-E CR
PM1/PM2.5/PM10/HCHO/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-228-E CR
PM1/PM2.5/PM10/TVOC/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-229-E CR
PM1/PM2.5/PM10/CO/CO2/HCHO/TVOC/Temperature/Humidity/Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
Consumption
Non-PoE: 2.3 W (Max.) PoE: 2.5 W (Max.)
Data logger
Yes, up to 450,000 records
Dimensions (mm)
Ø 150 x 53 (Ø x H)
EWB-C150
External Wall Box for the CL-200 series
FLT-C002
Replaceable Filter Patch
Humidity
10 ~ 90% RH, Non-condensing
Ingress Protection Rating
IP20
Installation
Ceiling Mounting/Wall Mounting
Operating Temperature
0 ~ 50°C
PoE
Yes
Ports
1 x RS-485 1 x Ethernet
Powered from Terminal Block
+12 ~ +48 VDC
PRODUCT SERIES
CL-220-E CR
DESCRIPTION PM1/PM2.5/PM10/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
Protocol
DCON and Modbus/RTU (RS-485) Modbus TCP and MQTT (Ethernet)
Real-time clock
Yes
Sizes
0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm
Storage Temperature
-30 ~ +75°C
Integration
Points to check before using CL-220-E in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range 0 ~ 50°C — check it against the installation environment.
Power and communication
Consumption
Non-PoE: 2.3 W (Max.) PoE: 2.5 W (Max.)
Powered from Terminal Block
+12 ~ +48 VDC
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range 0 ~ 50°C — check it against the installation environment.
Applications and use cases
Architectures in which CL-220-E can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productICP DAS
CL-220-E
PM1/PM2.5/PM10, temperature and humidity air quality data logger
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details