The CL-226-E is an ICP DAS data logger module measuring PM1, PM2.5, PM10, H2S, temperature, humidity and dew point, with RS-485 and Ethernet PoE communication.
Operating Temperature0 ~ 50°C
ConsumptionNon-PoE: 2.3 W (Max.) PoE: 2.5 W (Max.)
Real-time clockYes
Storage Temperature-30 ~ +75°C
Dimensions (mm)Ø 150 x 53 (Ø x H)
CA-RJ45-04RJ45 Cable, Male-Female, 30 cm (90º)
Product overview
ICP DAS CL-226-E data logger. The CL-226-E is a data logger module from manufacturer ICP DAS, designed for air quality monitoring. It measures PM1, PM2.5, PM10, H2S, temperature, humidity and dew point.
Main characteristics. The module records up to 450,000 time-stamped records, and includes a real-time clock and a relay output for alarm or indoor air quality device control. The particle sizes measured are 0.3μm, 0.5μm, 1μm, 2.5μm, 5μm and 10μm.
Interfaces and connectivity. The module provides one RS-485 port and one Ethernet port, with PoE power. It supports DCON and Modbus/RTU protocols over RS-485, and Modbus TCP and MQTT over Ethernet. A web-based configuration interface is included.
Power and environment. Powered from a terminal block at +12 to +48 VDC or via PoE, consumption of 2.3 W maximum without PoE and 2.5 W maximum with PoE. Operating temperature 0 to 50°C, storage temperature -30 to +75°C, humidity 10 to 90% RH non-condensing, IP20 ingress protection. Ceiling or wall mounting, with the EWB-C150 external wall box available as an option.
Typical uses. Indoor air quality monitoring and environmental data logging, with measurements sent to a PLC or supervision system via Modbus.
Integration. The utility software, together with the iOS and Android apps, is provided for configuration and data retrieval. The module is available on quotation from Atlas Electronics.
The CL-226-E is an ICP DAS data logger module measuring PM1, PM2.5, PM10, H2S, temperature, humidity and dew point, with RS-485 and Ethernet PoE communication.
Operating Temperature0 ~ 50°C
ConsumptionNon-PoE: 2.3 W (Max.) PoE: 2.5 W (Max.)
PM1/PM2.5/PM10/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-221-E CR
PM1/PM2.5/PM10/CO/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-222-E CR
PM1/PM2.5/PM10/CO /Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS) 2
CL-223-E CR
PM1/PM2.5/PM10/CO/CO /Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS) 2
CL-224-E CR
PM1/PM2.5/PM10/HCHO/TVOC/Temperature/Humidity/Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-225-E CR
PM1/PM2.5/PM10/NH /Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS) 3
CL-226-E CR
PM1/PM2.5/PM10/H S/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS) 2
CL-227-E CR
PM1/PM2.5/PM10/HCHO/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-228-E CR
PM1/PM2.5/PM10/TVOC/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-229-E CR
PM1/PM2.5/PM10/CO/CO2/HCHO/TVOC/Temperature/Humidity/Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
Consumption
Non-PoE: 2.3 W (Max.) PoE: 2.5 W (Max.)
Data logger
Yes, up to 450,000 records
Dimensions (mm)
Ø 150 x 53 (Ø x H)
EWB-C150
External Wall Box for the CL-200 series
FLT-C002
Replaceable Filter Patch
Humidity
10 ~ 90% RH, Non-condensing
Ingress Protection Rating
IP20
Installation
Ceiling Mounting/Wall Mounting
Operating Temperature
0 ~ 50°C
PoE
Yes
Ports
1 x RS-485 1 x Ethernet
Powered from Terminal Block
+12 ~ +48 VDC
PRODUCT SERIES
CL-226-E CR
DESCRIPTION PM1/PM2.5/PM10/H2S/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
Protocol
DCON and Modbus/RTU (RS-485) Modbus TCP and MQTT (Ethernet)
Real-time clock
Yes
Sizes
0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm
Storage Temperature
-30 ~ +75°C
Integration
Points to check before using CL-226-E in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range 0 ~ 50°C — check it against the installation environment.
Power and communication
Consumption
Non-PoE: 2.3 W (Max.) PoE: 2.5 W (Max.)
Powered from Terminal Block
+12 ~ +48 VDC
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range 0 ~ 50°C — check it against the installation environment.
Applications and use cases
Architectures in which CL-226-E can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details