ICP DAS air quality data logger module measuring PM1, PM2.5 and PM10 particles, HCHO, TVOC, temperature and humidity, with RS-485 and Ethernet PoE communication.
Operating Temperature0 ~ 50°C
ConsumptionNon-PoE: 2.3 W (Max.) PoE: 2.5 W (Max.)
Real-time clockYes
Storage Temperature-30 ~ +75°C
Dimensions (mm)Ø 150 x 53 (Ø x H)
CA-RJ45-04RJ45 Cable, Male-Female, 30 cm (90º)
Product overview
ICP DAS CL-224-E. The CL-224-E is a data logger module from manufacturer ICP DAS. It measures PM1, PM2.5 and PM10 particles, HCHO, TVOC, temperature, humidity and dew point.
Measurement and recording. It records up to 450,000 time-stamped records using its real-time clock. Particles are measured in the sizes 0.3μm, 0.5μm, 1μm, 2.5μm, 5μm and 10μm. Humidity range: 10 to 90% RH, non-condensing.
Interfaces and communication. The module provides one RS-485 port and one Ethernet port. It supports DCON and Modbus/RTU over RS-485, and Modbus TCP and MQTT over Ethernet. It is powered by PoE or from a terminal block at +12 to +48 VDC.
Power and environment. Consumption of 2.3 W maximum without PoE and 2.5 W maximum with PoE. Operating temperature 0 to 50°C, storage temperature -30 to +75°C. Ingress protection rating IP20.
Installation and integration. The enclosure measures Ø 150 x 53 mm and can be mounted on the ceiling or on a wall. The EWB-C150 external wall box and the replaceable FLT-C002 filter patch are available as accessories. A 30 cm (90º) RJ45 cable, CA-RJ45-04, is also available. The module includes a relay output (Form A, 16 A) usable for an alarm or for controlling an air quality device.
ICP DAS air quality data logger module measuring PM1, PM2.5 and PM10 particles, HCHO, TVOC, temperature and humidity, with RS-485 and Ethernet PoE communication.
Operating Temperature0 ~ 50°C
ConsumptionNon-PoE: 2.3 W (Max.) PoE: 2.5 W (Max.)
PM1/PM2.5/PM10/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-221-E CR
PM1/PM2.5/PM10/CO/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-222-E CR
PM1/PM2.5/PM10/CO /Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS) 2
CL-223-E CR
PM1/PM2.5/PM10/CO/CO /Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS) 2
CL-224-E CR
PM1/PM2.5/PM10/HCHO/TVOC/Temperature/Humidity/Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-225-E CR
PM1/PM2.5/PM10/NH /Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS) 3
CL-226-E CR
PM1/PM2.5/PM10/H S/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS) 2
CL-227-E CR
PM1/PM2.5/PM10/HCHO/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-228-E CR
PM1/PM2.5/PM10/TVOC/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
CL-229-E CR
PM1/PM2.5/PM10/CO/CO2/HCHO/TVOC/Temperature/Humidity/Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
Consumption
Non-PoE: 2.3 W (Max.) PoE: 2.5 W (Max.)
Data logger
Yes, up to 450,000 records
Dimensions (mm)
Ø 150 x 53 (Ø x H)
EWB-C150
External Wall Box for the CL-200 series
FLT-C002
Replaceable Filter Patch
Humidity
10 ~ 90% RH, Non-condensing
Ingress Protection Rating
IP20
Installation
Ceiling Mounting/Wall Mounting
Operating Temperature
0 ~ 50°C
PoE
Yes
Ports
1 x RS-485 1 x Ethernet
Powered from Terminal Block
+12 ~ +48 VDC
PRODUCT SERIES
CL-224-E CR
DESCRIPTION PM1/PM2.5/PM10/HCHO/TVOC/Temperature/Humidity/ Dew Point Data Logger Module (RS-485, Ethernet PoE) (RoHS)
Protocol
DCON and Modbus/RTU (RS-485) Modbus TCP and MQTT (Ethernet)
Real-time clock
Yes
Sizes
0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm
Storage Temperature
-30 ~ +75°C
Integration
Points to check before using CL-224-E in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range 0 ~ 50°C — check it against the installation environment.
Power and communication
Consumption
Non-PoE: 2.3 W (Max.) PoE: 2.5 W (Max.)
Powered from Terminal Block
+12 ~ +48 VDC
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range 0 ~ 50°C — check it against the installation environment.
Applications and use cases
Architectures in which CL-224-E can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productICP DAS
CL-224-E
Air quality data logger for PM, HCHO, TVOC, temperature and humidity
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details