CL-229
IAQ data logger with PM, CO, CO2, HCHO, TVOC, Wi-Fi and PoE

IAQ data logger with PM, CO, CO2, HCHO, TVOC, Wi-Fi and PoE
Multiparameter data logger for indoor air quality, measuring PM1, PM2.5 and PM10 particles, CO, CO2, HCHO, TVOC, temperature, humidity and dew point, with Ethernet, RS-485 and Wi-Fi interfaces.
CL-229-WF. The ICP DAS CL-229-WF is a data logger module measuring PM1/PM2.5/PM10 particles, CO, CO2, HCHO, TVOC, temperature, humidity and dew point.
Main characteristics. The CO2 sensor is a non-dispersive infrared (NDIR) type. Particles are measured in six sizes: 0.3 μm, 0.5 μm, 1 μm, 2.5 μm, 5 μm and 10 μm. Records carry date and time stamps and up to 450,000 records can be stored. A real-time clock is included.
Interfaces and connectivity. The module provides one RS-485 port and one Ethernet port. DCON and Modbus RTU are supported over RS-485, Modbus TCP over Ethernet and Wi-Fi, and MQTT over Ethernet. Wi-Fi follows IEEE 802.11 b/g/n in infrastructure and limited AP modes. WEP, WPA and WPA2 encryption is available, together with IP filtering (whitelist) and a password for the web interface. A relay output allows control of an alarm or indoor air quality device.
Power and environment. The module accepts two redundant power inputs: PoE (IEEE 802.3af, Class 1) and a DC input of +12 to +48 VDC via terminal block. Consumption is 3.3 W maximum without PoE and 3.5 W maximum with PoE. It operates between 0 and 50 °C at 10 to 90 % RH non-condensing, with an IP20 ingress protection rating. It can be ceiling or wall mounted; the EWB-C150 external wall box is available for the CL-200 series.
Typical uses and integration. With its RS-485 port and Modbus RTU and Modbus TCP protocols, the module can be connected to PLCs or supervisory systems. The MQTT protocol enables data transmission to IIoT platforms over Ethernet. A 1 dBi PCB antenna is supplied, with an output power of 18 dBm in DSSS and a transmission range of 50 metres line of sight.
No published question about this part yet. Questions are reviewed before publication.
Official documents and the technical data recorded for CL-229. For a missing document or a specific revision, our experts send it to you.
Multiparameter data logger for indoor air quality, measuring PM1, PM2.5 and PM10 particles, CO, CO2, HCHO, TVOC, temperature, humidity and dew point, with Ethernet, RS-485 and Wi-Fi interfaces.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
IAQ data logger with PM, CO, CO2, HCHO, TVOC, Wi-Fi and PoE

SDLogger - Open Hardware Data Logger

Data Logger Ultrasonic River Flow Meter Open Channel Flowmeters

Weather Station Data Logger Modbus

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | CL-229 |
| Manufacturer | ICP DAS |
Data Loggers
IoT edge gateway data logger with RS485 and 4G · Ref. : 4G/WIFI/GPS/RS232/RS485
Price on request
Data Loggers
RS485 data logger for solar systems · Ref. : ELOG01-G3
Price on request
Data Loggers
Long-duration data logger with continuous sampling for oscilloscope
Price on request
Data Loggers
3-channel IEPE accelerometer and 1-channel thermistor data logger
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details