KEW 6516 – Portable installation tester with ATT loop and RCD testing

Portable installation tester with ATT loop and RCD testing

Installation and Earth Testers

  • USB
  • -10 to +10%
  • 0 to +10%
  • ‐
Manufacturer part number
KEW_6516
Manufacturer
Kyoritsu
Communication interface
USB
Measuring; current — 15mA
15mA±3mA(short-circuit)

Kyoritsu KEW 6516 multifunction tester for verifying electrical installations: loop impedance, residual current devices, earth resistance, insulation and continuity.

Product overview

Overview. The Kyoritsu KEW 6516 is a multifunction electrical installation tester, listed under "Installation and Earth Testers" by the manufacturer, intended for electrical installation professionals.

Measurement functions. Loop impedance with a high test current range and 0.001 Ω resolution, with the Zs/Ra limit function giving a PASS or FAIL result. RCD trip testing for AC, A, F, B and EV types, with ramp test and contact voltage. Earth resistance with 2 and 3 wire methods. Insulation resistance at 100, 250, 500 and 1000 V with automatic discharge. Continuity at 200 mA or 15 mA. TRMS voltage measurement from 2 to 600 V and mains frequency from 45 to 65 Hz. Varistor-based surge protection device (SPD) testing and portable appliance tester (PAT) functions.

Main characteristics. 3.5-inch colour LCD, phase rotation indicated on the display for three-phase lines, help function showing how to connect the instrument for the selected function. Powered by 8 LR6 (AA) 1.5 V batteries. Dimensions 136 × 235 × 114 mm, 1350 g including batteries.

Interfaces and connectivity. USB interface, with the KEW Report PC application for managing measurement reports.

Power and environment. Rated voltage 100 to 260 V (50/60 Hz), IP40 protection.

Standards and compliance. IEC 61010-1 CAT IV 300 V / CAT III 600 V, pollution degree 2; IEC 61010-2-034; IEC 61557-1, 2, 3, 4, 5, 6, 7 and 10; IEC 60529; IEC 61326 (EMC).

Accessories. Test leads, remote control switch test leads 7281, distribution board test lead 7246, earth resistance test leads 7228A, auxiliary earth spikes 8041, soft case, carrying case, shoulder strap and USB adapter 8212-USB. Calibration certificate and instruction manual included. Optional accessories: measurement terminal adapter 8259, precision measurement cord set 7272 and EVSE adapter 8602.

See all specifications

Highlights

  • Accuracy — ±3%rdg±6dgt — ±3%rdg±10dgt — ±3%rdg±4dgt — ±3%rdg±25m&Omega: ±3%rdg±4dgt
  • Accuracy — Frequency: ±0.5%rdg±2dgt
  • Accuracy — Trip; current — Ramp — -4 to +4%: -10 to +10%
  • Accuracy — Trip; current — x1 — +2 to +8%: 0 to +10%
  • Accuracy — Trip; time — x1 — 550ms(G):±1%rdg±2ms,1000ms(S):±1%rdg±2ms: 10.5s:±1%±2㎳
  • Accuracy — Volts: ±2%rdg±4dgt

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.