KEW_8121
AC 100 A clamp meter with voltage output

- Rated Current
- AC 100A
- Output voltage
- AC 500mV/100A (AC 5mV/A)
- Cable Length
- Approx. 2m
- Conductor size
- Ø 24mm
AC 100 A clamp meter with voltage output
The Kyoritsu KEW 8121 clamp meter measures AC currents up to 100 A through a 5 mV/A voltage output, for AC current measurement and recording.
Overview. The Kyoritsu KEW 8121 is an AC clamp meter with a rated current of AC 100 A and a 24 mm jaw diameter for large-section conductors.
Main characteristics. The output signal is an AC voltage of 500 mV for 100 A, that is 5 mV/A, with an output impedance of approximately 9.5 Ω. Accuracy is ±2.0% of reading ±0.3 mV at 50/60 Hz and ±3.0% of reading ±0.5 mV from 40 Hz to 1 kHz.
Connectivity and output. The output uses a MINI DIN 6-pin connector, with a cable of approximately 2 m. The 7146 adapter (Ø 4 mm banana plug) and the 7185 extension cable are available as options.
Power and environment. The operating range is 0 to 40 °C with relative humidity of 85% or less, no condensation. Dimensions are 97 x 59 x 26 mm for approximately 150 g.
Safety and standards. Compliant with IEC 61010-1 and IEC 61010-2-032, CAT III 300 V, pollution degree 2, and with the EMC standard IEC 61326.
Typical uses. AC current measurement on installations and conductors, with the voltage output signal read by a compatible measuring or acquisition device.
Supplied with. A carrying case (model 9095), an instruction manual and a cable marker.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for KEW_8121, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Output voltage | AC 500mV/100A (AC 5mV/A) |
| Accessories | 9095 (Carrying case); Instruction manual, Cable marker |
| Accuracy | ±2.0%rdg±0.3mV (50/60Hz); ±3.0%rdg±0.5mV (40Hz to 1kHz) |
| Applicable Standards | IEC 61010-1, IEC 61010-2-032 CAT III 300V pollution degree 2, IEC 61326 |
| Cable Length | Approx. 2m |
| Conductor size | Ø 24mm |
| Dimension | 97(L) x 59(W) x 26(D) mm |
| Operating temperature and humidity range | 0 to 40°C, relative humidity 85% or less (no condensation) |
| Optional Accessories | 7146 (Banana Ø 4 adjuster plug); 7185 (Extension Cable) |
| Output Connector: | MINI DIN 6PIN |
| Output Impedance | Approx. 9.5&Omega |
| Product Catalog | KEW 8121 Product Catalog (English)(1.43 MB) |
| Rated Current | AC 100A |
| Weight | Approx.150g |
No specification matches.
Last verification : 2026-11-03
Official documents and the technical data recorded for KEW_8121. For a missing document or a specific revision, our experts send it to you.
The Kyoritsu KEW 8121 clamp meter measures AC currents up to 100 A through a 5 mV/A voltage output, for AC current measurement and recording.
| Parameter | Value |
|---|---|
| Output voltage | AC 500mV/100A (AC 5mV/A) |
| Accessories | 9095 (Carrying case); Instruction manual, Cable marker |
| Accuracy | ±2.0%rdg±0.3mV (50/60Hz); ±3.0%rdg±0.5mV (40Hz to 1kHz) |
| Applicable Standards | IEC 61010-1, IEC 61010-2-032 CAT III 300V pollution degree 2, IEC 61326 |
| Cable Length | Approx. 2m |
| Conductor size | Ø 24mm |
| Dimension | 97(L) x 59(W) x 26(D) mm |
| Operating temperature and humidity range | 0 to 40°C, relative humidity 85% or less (no condensation) |
| Optional Accessories | 7146 (Banana Ø 4 adjuster plug); 7185 (Extension Cable) |
| Output Connector: | MINI DIN 6PIN |
| Output Impedance | Approx. 9.5&Omega |
| Product Catalog | KEW 8121 Product Catalog (English)(1.43 MB) |
| Rated Current | AC 100A |
| Weight | Approx.150g |
Points to check before using KEW_8121 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Output voltage | AC 500mV/100A (AC 5mV/A) |
| Rated Current | AC 100A |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of KEW_8121 can answer. A question is not asked when nothing is recorded to answer it.
0 to 40°C, relative humidity 85% or less (no condensation) (source: Operating temperature and humidity range).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
AC 100 A clamp meter with voltage output

MODEL 8141

KEW 8130

MODEL 8125

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | KEW_8121 |
| Manufacturer | Kyoritsu |
Clamp Meters
AC clamp sensor for digital multimeter · Ref. : KEW_8161
Price on request
Clamp Meters
2-Phase Clamp Voltammeter with Phase Diagram Display · Ref. : UT265B
Price on request
Clamp Meters
AC DC Clamp Digital Multimeter 750 V 600 A · Ref. : DMC-100
Price on request
Clamp Meters
AC clamp meter with 500 mV output for KEW 5050 leakage · Ref. : KEW_8178
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details