MODEL 8141 – AC clamp meter for 1000 A current measurement

AC clamp meter for 1000 A current measurement

Clamp Meters

  • AC 1000mA
  • Approx. 2m
  • Ø 24mm
  • MINI DIN 6pin
Manufacturer part number
MODEL_8141
Manufacturer
Kyoritsu
Rated Current
AC 1000mA
Output voltage
AC 100mV/1000mA (AC 100mV/A)

The Kyoritsu MODEL 8141 clamp meter is an AC current sensor with voltage output, designed to measure alternating current up to 1000 A on a 24 mm conductor.

Product overview

Overview. The Kyoritsu MODEL 8141 is an AC clamp meter, a current sensor with voltage output and a rated current of 1000 A AC. The product is listed in the clamp meter category of the manufacturer. It is marked as a discontinued product.

Main characteristics. The clamp accepts a conductor of 24 mm diameter (Ø 24 mm). Its output delivers AC 100 mV/1000 mA, that is AC 100 mV/A, with an output impedance of approximately 180 Ω. Accuracy is ±1.0% of reading ±0.1 mV at 50/60 Hz, and ±2.0% of reading ±0.1 mV between 40 Hz and 1 kHz. The manufacturer states that the clamp cannot be used for power measurement.

Interfaces and connectivity. The output uses a MINI DIN 6-pin connector. A cable of approximately 2 m is supplied. Optional accessories are the banana adapter plug Ø 4 mm reference 7146 and the extension cable reference 7185.

Power and environment. The data do not specify a power supply for this product. It operates between 0 and 50 °C with humidity below 85% RH, without condensation.

Safety and standards. The clamp complies with IEC 61010-1 and IEC 61010-2-032, with a CAT III 300 V measurement category and pollution degree 2.

Dimensions and weight. Dimensions of 100 x 60 x 26 mm for a weight of approximately 150 g. A portable case reference 9095 and an instruction manual are supplied.

Typical uses. This clamp suits AC current measurement on a 24 mm conductor, with a voltage output usable by a compatible measuring instrument.

See all specifications

Highlights

  • Output voltage: AC 100mV/1000mA (AC 100mV/A)
  • Accessories: 9095 (Portable case), Instruction manual
  • Accuracy: ±1.0%rdg±0.1mV (50/60Hz) ±2.0%rdg±0.1mV (40Hz - 1kHz)
  • Applicable Standards: IEC 61010-1, IEC 61010-2-032, CAT III 300V pollution degree 2
  • Cable Length: Approx. 2m
  • Dimension: 100(L) x 60(W) x 26(D) mm

Good to know before integrating

  • Thermal: rated operating range 0 - 50º C, less than 85% RH (without condensation) — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Clamp Meters
Request a quote