TF1100-EI – Transit-time insertion ultrasonic flow meter with data logging

Transit-time insertion ultrasonic flow meter with data logging

Data Loggers

  • -20℃ to +60℃
  • DN65-6000
  • 0.5s
  • Std:10m
Manufacturer part number
DATA-LOGGER-TRANSIT-TIME-INSERTION-ULTRASONIC-WATER-FLOW-METER
Manufacturer
Lanry
Operating Temperature
-20℃ to +60℃
Pipe diameter range
DN65-6000

Transit-time insertion ultrasonic flow meter for measuring liquid flow from outside the pipe, with a data logger function.

Product overview

Overview. The Lanry TF1100-EI transit-time insertion ultrasonic flow meter, referenced DATA-LOGGER-TRANSIT-TIME-INSERTION-ULTRASONIC-WATER-FLOW-METER, measures the flow of clean or somewhat dirty liquids with turbidity below 10000 ppm, from outside the pipe. The measurement principle is based on the ultrasonic transit-time difference correlation.

Main characteristics. Flow velocity range of 0.01 to 12 m/s, bi-directional, for pipe diameters from DN65 to DN6000. Accuracy of ±1.0% of reading above 0.3 m/s and ±0.003 m/s below, repeatability of 0.2% of reading and resolution of 0.25 mm/s. Response time of 0.5 s and user-selectable display damping from 0 to 99 s.

Interfaces and connectivity. 4~20 mA output (accuracy 0.1%), OCT, relay, RS232, RS485 with Modbus protocol, and a data logger. The RS485 Modbus output allows integration into a supervision system.

Power and environment. Power supply AC 85-265 V or DC 24 V/500 mA. Degree of protection IP66 according to EN60529, operating temperature -20 °C to +60 °C, standard liquid temperature -35 °C to 85 °C. Fiberglass wall-mounted enclosure, stainless steel transducers, size 244*196*114 mm, weight 2.4 kg.

Typical uses. Measurement of water and liquid flow in pipelines without interrupting the line, thanks to hot-tapped transducer installation. The absence of moving parts and pressure drop limits maintenance. Thermal energy calculation is possible when paired temperature sensors are configured.

Integration. 4-line by 16-character backlit graphic LCD display, with keypad and system lockout. Units user-configurable in English and metric.

See all specifications

Highlights

  • Response time: 0.5s
  • Cable Length: Std:10m
  • Communication: 4~20mA(accuracy 0.1%),OCT, Relay, RS232, RS485 (Modbus),data logger
  • Damping of displayed value: 0-99s(selectable by user)
  • Degree of protection: IP66 according to EN60529
  • Display: 4 line×16 English letters LCD graphic display, backlit

Good to know before integrating

  • Thermal: rated operating range -20℃ to +60℃ — check it against the installation environment.