Overview. The Lanry DOF6000 flow meter combines a flow calculator with the Ultraflow QSD 6537 sensor to measure water velocity, depth and electrical conductivity in rivers, streams, open channels and partially filled pipes. The calculator can determine flow rate and total flow from the cross-sectional area, described by up to 20 coordinate points.
Measurement principle. Velocity is measured by the ultrasonic Doppler principle in quadrature sampling mode, in both flow directions, from 20 mm/s to 12 m/s with an accuracy of ±1 % of the measured velocity and a resolution of 1 mm/s. Depth can be measured by ultrasonic sensor (20 mm to 5 m, ±1 % of measurement, resolution 1 mm) or by pressure sensor (0 to 10 m, ±1 % of measurement, resolution 1 mm), depending on the application. Electrical conductivity is measured by a four-electrode cell, from 0 to 200,000 µS/cm, with a typical accuracy of ±1 % of measurement.
Outputs and logging. The system provides a pulse output, a 4-20 mA output (flow and depth), an RS485 output using Modbus RTU with up to 500 m of cable, an SDI-12 v1.3 output up to 50 m, a data logger with 16 GB of storage and a GPRS output. The 4.5-inch colour LCD display simplifies configuration and on-site reading.
Power and environment. The calculator is powered from 85-265 VAC with battery charging, and the rechargeable battery can run for up to 50 hours. The sensor, with an epoxy-sealed body and a marine grade 316 stainless steel mounting bracket, has an IP68 rating. It operates between 0 °C and +60 °C and is stored between -20 °C and +60 °C. The standard cable is 15 m, with a maximum option of 500 m. Temperature accuracy is ±0.5 °C.
Typical uses. This flow meter suits flow measurement in culverts, channels and watercourses, and connection to a PLC or supervisory system via RS485/Modbus. The choice between ultrasonic and pressure depth measurement adapts it to side mounting on a pipe or to a clear open channel.