R718CTAB – Wireless Type T Thermocouple and Temperature/Humidity Sensor LoRaWAN

Wireless Type T Thermocouple and Temperature/Humidity Sensor LoRaWAN

Environmental Sensor Nodes

  • -20℃–55℃
  • -20°C to 55°C
  • -40℃ ≤ t ≤ 125℃
  • 0%RH to 100%RH
Manufacturer part number
R718CTAB
Manufacturer
Netvox
Operating Temperature
-20°C to 55°C
Environment Humidity Range
<90%RH (No condensation)

Netvox R718CTAB LoRaWAN sensor combining a type T thermocouple with a built-in temperature and humidity probe, for remote measurement on 2 AA lithium batteries.

Product overview

Overview. The Netvox R718CTAB is a LoRaWAN wireless sensor combining a type T thermocouple with a built-in temperature and humidity sensor. The thermocouple measures from -40 °C to 125 °C with a Ø 5 mm x 30 mm probe on a 1 m wire.

Measurement characteristics. The built-in sensor measures temperature from -20 °C to 55 °C with ±0.8 °C accuracy and humidity from 0 %RH to 100 %RH with ±4 %RH accuracy. The operating range is -20 °C to 55 °C, with humidity below 90 %RH and no condensation.

Connectivity. The R718CTAB communicates over LoRaWAN, with LoRa or FSK modulation (one to be selected) and a built-in antenna. The EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3, IN865-867 and CN470-510 bands are configured before shipment. Range reaches 10 km in line of sight, depending on the environment. Receiving sensitivity is -136 dBm in LoRa (Spreading Factor 12, bit rate 293 bps).

Power. The sensor runs on 2 ER14505 AA lithium batteries of 3.6 V and 2400 mAh each. The stated battery life is 4.8 years, under conditions of 25 °C, a report every 15 minutes, a Txpower of 20 dBm and a LoRa Spreading Factor of 10. The low voltage threshold is 3.2 V.

Dimensions. The main body measures 112 mm x 88.19 mm x 32 mm.

See all specifications

Highlights

  • Dimensions: Main body:112mm (L) x 88.19mm (W) x 32mm (H)
  • Antenna Type: Built-in antenna
  • Battery Low Voltage Threshold: 3.2V
  • Battery Measurement Accuracy: ±0.1V
  • Environment Humidity Range: <90%RH (No condensation)
  • Environment Temperature Range: -20℃–55℃

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -20°C to 55°C — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.