The Netvox R900PB03AO1 ultrasonic level sensor measures levels from 0.25 to 8 m from the top of a tank. It reports its measurements over LoRaWAN and provides a 3.3 V digital output.
Ambient Operating Temperature-20℃ to +55℃
Operating Temperature-20°C ~ 55°C
Operating Humidity Range<90%RH (No condensation)
Frequency Range863MHz-928MHz 470MHz-510MHz
Measurement Range0.25-8m
Operating Current< 15mA
Product overview
Netvox R900PB03AO1. wireless top-mounted ultrasonic level sensor with 1 x 3.3 V digital output, designed for level measurement over LoRaWAN.
Main characteristics. Measurement range of 0.25 to 8 m, blind zone of 0 to 0.25 m, detection angle of about 15° and accuracy of ±(1+S*0.3%) cm, S being the detected distance. The sensor connects through a 1 m cable.
Connectivity. LoRaWAN (Class A) communication with LoRa or FSK modulation, on the EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3, IN865-867 and CN470-510 bands, configured before shipment. Range up to 10 km in line of sight, depending on the environment. Built-in antenna.
Power and environment. Powered by 2 x ER18505 3.6V 4000mAh lithium batteries, with a battery lifespan of 5.97 years under the manufacturer's test conditions. Housing dimensions 115.5 x 60 x 54 mm, operating from -20°C to 55°C, humidity below 90% RH without condensation.
Installation. Mounting by screws, double-sided tape or bracket, with optional DIN rail, magnetic or swivel bracket.
5.97 years (when powered by 2* ER18505 batteries, the temperature = 25℃, report once every 30 minutes, TX power = 20dBm, and LoRa SF = 10) Battery life may vary depending on the report interval, TX power, and spreading factor (SF). It can be calculated and updated according to the following website: http://elecalc.netvoxcloud.com:8080/electric_calc/electric_calc.html?lang= cn
Battery Low Voltage Alarm
3.3V
Battery Measurement Accuracy
0.1V
Battery Measurement Error
±0.1V
Blind Distance
0m to 0.25m
Blind Zone
0-0.25m
Cable Length
1 m
Communication Distance
Up to 10 km; (visible linear obstacle-free transmission distance, actual transmission distance depends on the environment )
Communication Range
10km (line of sight) Note: The actual transmission distance depends on the environment.
Data Transfer Rate
FSK: 0.6 – 300Kbit/s; LoRa: 0.018 – 62.5Kbit/s
Detection Angle
About15°
Digital Out Voltage
3.3V
Dimension
Host body:115.5mm x W: 60mm x H: 54mm
Frequency Range
863MHz-928MHz 470MHz-510MHz
Installation
Standard: screws, double-sided tape, bracket; Prepared by Customer: cable ties; Optional: DIN rail, magnetic, swivel bracket
Low Voltage Alarm
3.2V
Measurement Accuracy
±(1+S*0.3%) cm S: the detected distance between the device and the detected object
Measurement Range
0.25-8m
Modulation
LoRa/FSK (Note: You can choose one of them)
Operating Current
< 15mA
Operating Humidity
<80% RH
Operating Humidity Range
<90%RH (No condensation)
Operating Temperature
-20°C ~ 55°C
Output
3V
Power supply
2* ER18505 3.6V 4000mAh lithium batteries
Receiving Sensitivity
–123 dBm for 2-FSK (at 1.2 Kbit/s),; –148 dBm for LoRa® (at 10.4 kHz, SF= 12)
RF Receiving Current
12mA @3.3V
RF Transmitting Current
138mA @3.3V, TX power = 22dB
RX Sensitivity
–123 dBm for 2-FSK (at 1.2 Kbit/s), –148 dBm for LoRa® (at 10.4 kHz, SF= 12)
Standby Current
33uA
Storage Temperature
-40°C ~ 85°C
Supportable LoRaWAN Band
EU863-870,US902-928,AU915-928,KR920-923,AS923-1,AS923-2,AS923-3,; IN865-867,CN470-510; (Note: The frequency band is optional and needs to be configured before shipment)
The Netvox R900PB03AO1 ultrasonic level sensor measures levels from 0.25 to 8 m from the top of a tank. It reports its measurements over LoRaWAN and provides a 3.3 V digital output.
5.97 years (when powered by 2* ER18505 batteries, the temperature = 25℃, report once every 30 minutes, TX power = 20dBm, and LoRa SF = 10) Battery life may vary depending on the report interval, TX power, and spreading factor (SF). It can be calculated and updated according to the following website: http://elecalc.netvoxcloud.com:8080/electric_calc/electric_calc.html?lang= cn
Battery Low Voltage Alarm
3.3V
Battery Measurement Accuracy
0.1V
Battery Measurement Error
±0.1V
Blind Distance
0m to 0.25m
Blind Zone
0-0.25m
Cable Length
1 m
Communication Distance
Up to 10 km; (visible linear obstacle-free transmission distance, actual transmission distance depends on the environment )
Communication Range
10km (line of sight) Note: The actual transmission distance depends on the environment.
Data Transfer Rate
FSK: 0.6 – 300Kbit/s; LoRa: 0.018 – 62.5Kbit/s
Detection Angle
About15°
Digital Out Voltage
3.3V
Dimension
Host body:115.5mm x W: 60mm x H: 54mm
Frequency Range
863MHz-928MHz 470MHz-510MHz
Installation
Standard: screws, double-sided tape, bracket; Prepared by Customer: cable ties; Optional: DIN rail, magnetic, swivel bracket
Low Voltage Alarm
3.2V
Measurement Accuracy
±(1+S*0.3%) cm S: the detected distance between the device and the detected object
Measurement Range
0.25-8m
Modulation
LoRa/FSK (Note: You can choose one of them)
Operating Current
< 15mA
Operating Humidity
<80% RH
Operating Humidity Range
<90%RH (No condensation)
Operating Temperature
-20°C ~ 55°C
Output
3V
Power supply
2* ER18505 3.6V 4000mAh lithium batteries
Receiving Sensitivity
–123 dBm for 2-FSK (at 1.2 Kbit/s),; –148 dBm for LoRa® (at 10.4 kHz, SF= 12)
RF Receiving Current
12mA @3.3V
RF Transmitting Current
138mA @3.3V, TX power = 22dB
RX Sensitivity
–123 dBm for 2-FSK (at 1.2 Kbit/s), –148 dBm for LoRa® (at 10.4 kHz, SF= 12)
Standby Current
33uA
Storage Temperature
-40°C ~ 85°C
Supportable LoRaWAN Band
EU863-870,US902-928,AU915-928,KR920-923,AS923-1,AS923-2,AS923-3,; IN865-867,CN470-510; (Note: The frequency band is optional and needs to be configured before shipment)
Points to check before using R900PB03AO1 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -20℃ to +55℃ — check it against the installation environment.
2Thermalrated operating range -20°C ~ 55°C — check it against the installation environment.
Power and communication
Battery Lifespan
5.97 years (when powered by 2* ER18505 batteries, the temperature = 25℃, report once every 30 minutes, TX power = 20dBm, and LoRa SF = 10) Battery life may vary depending on the report interval, TX power, and spreading factor (SF). It can be calculated and updated according to the following website: http://elecalc.netvoxcloud.com:8080/electric_calc/electric_calc.html?lang= cn
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20℃ to +55℃ — check it against the installation environment.
Thermal : rated operating range -20°C ~ 55°C — check it against the installation environment.
Applications and use cases
Architectures in which R900PB03AO1 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for R900PB03AO1 and the other parts of your project.
Answers to the questions that the recorded characteristics of R900PB03AO1 can answer. A question is not asked when nothing is recorded to answer it.
1Does it support CAN bus?
Yes — recorded under "Battery Lifespan": 5.97 years (when powered by 2* ER18505 batteries, the temperature = 25℃, report once every 30 minutes, TX power = 20dBm, and LoRa SF = 10) Battery life may vary depending on the report interval, TX power, and spreading factor (SF). It can be calculated and updated according to the following website: http://elecalc.netvoxcloud.com:8080/electric_calc/electric_calc.html?lang= cn.
2Does it support LoRaWAN?
Yes — recorded under "Available LoRaWAN Band": EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3, IN865-867, CN470-510 Note: configured before shipment.
3What is the operating temperature range?
-20℃ to +55℃ (source: Ambient Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details