Netvox R900PD01AO1 wireless sensor measuring water pH, turbidity and residual chlorine, with results sent over LoRaWAN. 3.3V digital output and IP68 RS-485 probes.
Ambient Operating Temperature-20℃ to +55℃
Operating Temperature-20°C ~ 55°C
Operating Water Temperature Range0 °C to +65°C
Water Temperature Range (Included with pH Sensor)0 to 65°C
Usable Pressure Range<0.2MPa
Operating Humidity Range<90%RH (No condensation)
Product overview
Overview. The Netvox R900PD01AO1 is a LoRaWAN water quality sensor measuring pH, turbidity and residual chlorine. It stands out with three IP68 probes connected to the housing by a 1 m cable.
Main characteristics. pH is measured from 0 to 14 pH with 0.01 pH resolution and an accuracy of -0.3 to +0.3 pH. Turbidity is measured from 0 to 1000 NTU by scattered light measurement, with 0.1 NTU resolution. Residual chlorine is measured from 0 to 10 mg/L with 0.01 mg/L resolution. Automatic temperature compensation (Pt1000) and two-point calibration are included.
Interfaces and connectivity. The sensor communicates over LoRaWAN (Class C) with LoRa or FSK modulation on the EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3, IN865-867 and CN470-510 bands, configured before shipment. The output is digital 3.3V and the probes communicate over RS-485. Range reaches 10 km in line of sight, depending on the environment.
Power and environment. The housing is powered from 12 VDC to 24 VDC and consumes 0.19 W. It operates from -20 °C to 55 °C and tolerates humidity below 90 %RH without condensation. The probes are rated IP68 and the water temperature range is 0 °C to 65 °C.
Typical uses. Continuous water quality monitoring in treatment or distribution installations, with measurements transmitted to a LoRaWAN-compatible system.
Installation. The housing mounts with screws, double-sided tape or a bracket, with optional DIN rail, magnetic or swivel bracket. Housing dimensions: 115.5 mm x 60 mm x 54 mm.
–123 dBm for 2-FSK (at 1.2 Kbit/s),; –148 dBm for LoRa® (at 10.4 kHz, SF= 12)
Residual Chlorine Measuring Range
0 –10mg/L
Resolution
0.01 mg/L
RX Sensitivity
–123 dBm for 2-FSK (at 1.2 Kbit/s), –148 dBm for LoRa® (at 10.4 kHz, SF= 12)
Signal Output
RS-485
Storage Temperature
-40°C ~ 85°C
Supportable LoRaWAN Band
EU863-870,US902-928,AU915-928,KR920-923,AS923-1,AS923-2,AS923-3,; IN865-867,CN470-510; (Note: The frequency band is optional and needs to be configured before shipment)
Netvox R900PD01AO1 wireless sensor measuring water pH, turbidity and residual chlorine, with results sent over LoRaWAN. 3.3V digital output and IP68 RS-485 probes.
Ambient Operating Temperature-20℃ to +55℃
Operating Temperature-20°C ~ 55°C
Operating Water Temperature Range0 °C to +65°C
Water Temperature Range (Included with pH Sensor)0 to 65°C
–123 dBm for 2-FSK (at 1.2 Kbit/s),; –148 dBm for LoRa® (at 10.4 kHz, SF= 12)
Residual Chlorine Measuring Range
0 –10mg/L
Resolution
0.01 mg/L
RX Sensitivity
–123 dBm for 2-FSK (at 1.2 Kbit/s), –148 dBm for LoRa® (at 10.4 kHz, SF= 12)
Signal Output
RS-485
Storage Temperature
-40°C ~ 85°C
Supportable LoRaWAN Band
EU863-870,US902-928,AU915-928,KR920-923,AS923-1,AS923-2,AS923-3,; IN865-867,CN470-510; (Note: The frequency band is optional and needs to be configured before shipment)
< 200 mA (connected pH, turbidity, and residual chlorine sensors)
Water Temperature Range (Included with pH Sensor)
0 to 65°C
Working Conditions
0 °C to +50°C, < 0.2 MPa
Working Principle
Scattered light measurement
Integration
Points to check before using R900PD01AO1 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -20℃ to +55℃ — check it against the installation environment.
2Thermalrated operating range -20°C ~ 55°C — check it against the installation environment.
< 200 mA (connected pH, turbidity, and residual chlorine sensors)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20℃ to +55℃ — check it against the installation environment.
Thermal : rated operating range -20°C ~ 55°C — check it against the installation environment.
Applications and use cases
Architectures in which R900PD01AO1 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for R900PD01AO1 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productNetvox
R900PD01AO1
LoRaWAN water pH, turbidity and residual chlorine sensor
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.