Netvox R900PD05AO1 wireless sensor measuring water pH, oxidation-reduction potential (ORP) and temperature, with RS-485 Modbus/RTU output and LoRaWAN communication.
Ambient Operating Temperature-20℃ to +55℃
Operating Temperature-20°C ~ 55°C
Operating Water Temperature Range0 °C to +65°C
Water Temperature Range (Included with pH Sensor)0 to 65°C
Usable Pressure Range<0.2MPa
Operating Humidity Range<90%RH (No condensation)
Product overview
Overview. The Netvox R900PD05AO1 is a LoRaWAN water pH, ORP and temperature sensor with a 3.3V digital output. It measures pH from 0 to 14 pH with 0.01 pH resolution and ORP from -1500 to +1500mV by platinum electrode method.
Main characteristics. ORP accuracy is ±20mV with 1mV resolution. pH accuracy is -0.3 to +0.3 pH. Temperature compensation is automatic (NTC) and calibration is one-point. Response time is below 30 s.
Interfaces and connectivity. The probe connects through a 1m cable over RS-485 (Modbus/RTU). The module communicates over LoRaWAN® Class C with LoRa or FSK modulation on the EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3, IN865-867 and CN470-510 bands, configured before shipment. Range reaches 10 km line of sight and depends on the environment. The antenna is built in.
Power and environment. Operating voltage 12 VDC to 24 VDC, power consumption 0.2W at 12V. The probe is rated IP68, operates in water from 0°C to +65°C and the unit from 0°C to 50°C at pressure below 0.2MPa. The ABS/PC alloy housing measures 115.5 x 60 x 54 mm and operates from -20°C to +55°C.
Typical uses and integration. The immersion probe suits water quality monitoring. The RS-485 Modbus/RTU output allows connection to a PLC or gateway. Mounting by screws, double-sided tape or bracket, with optional DIN rail, magnetic or swivel bracket.
Up to 10 km; (visible linear obstacle-free transmission distance, actual transmission distance depends on the environment )
Communication Range
10km (line of sight) Note: The actual transmission distance depends on the environment.
Data Transfer Rate
FSK: 0.6 – 300Kbit/s; LoRa: 0.018 – 62.5Kbit/s
Digital Out Voltage
3.3V
Dimension
Host body:115.5mm x W: 60mm x H: 54mm
Frequency Range
863MHz-928MHz 470MHz-510MHz
Housing Material
ABS/PC alloy
Installation
Standard: screws, double-sided tape, bracket; Prepared by Customer: cable ties; Optional: DIN rail, magnetic, swivel bracket
Installation Method
Immersion installation
Measuring Principle
Platinum electrode method
Measuring Range
-1500~+1500mV
Modulation
LoRa/FSK (Note: You can choose one of them)
Operating Humidity Range
<90%RH (No condensation)
Operating Temperature
-20°C ~ 55°C
Operating Voltage
12 VDC to 24 VDC
Operating Water Temperature Range
0 °C to +65°C
Operation Conditions
0 to 50℃ ≤0.2MPa
ORP Sensor
-1500 ~ +1500mV
pH Range
0 to 14PH
PH Resolution
0.01 pH
PH Value Accuracy
-0.3pH to + 0.3 pH
PH Value Range
0 to 14pH
Power consumption
0.2W@12V
Power supply
DC 12V
Protection Level
IP68
Receiving Sensitivity
–123 dBm for 2-FSK (at 1.2 Kbit/s),; –148 dBm for LoRa® (at 10.4 kHz, SF=12)
Resolution
1mV
RX Sensitivity
–123 dBm for 2-FSK (at 1.2 Kbit/s), –148 dBm for LoRa® (at 10.4 kHz, SF= 12)
Signal Output
RS-485 (Modbus/RTU)
Storage Temperature
-40°C ~ 85°C
Supportable LoRaWAN Band
EU863-870,US902-928,AU915-928,KR920-923,AS923-1,AS923-2,AS923-3,; IN865-867,CN470-510; (Note: The frequency band is optional and needs to be configured before shipment)
Netvox R900PD05AO1 wireless sensor measuring water pH, oxidation-reduction potential (ORP) and temperature, with RS-485 Modbus/RTU output and LoRaWAN communication.
Ambient Operating Temperature-20℃ to +55℃
Operating Temperature-20°C ~ 55°C
Operating Water Temperature Range0 °C to +65°C
Water Temperature Range (Included with pH Sensor)0 to 65°C
Up to 10 km; (visible linear obstacle-free transmission distance, actual transmission distance depends on the environment )
Communication Range
10km (line of sight) Note: The actual transmission distance depends on the environment.
Data Transfer Rate
FSK: 0.6 – 300Kbit/s; LoRa: 0.018 – 62.5Kbit/s
Digital Out Voltage
3.3V
Dimension
Host body:115.5mm x W: 60mm x H: 54mm
Frequency Range
863MHz-928MHz 470MHz-510MHz
Housing Material
ABS/PC alloy
Installation
Standard: screws, double-sided tape, bracket; Prepared by Customer: cable ties; Optional: DIN rail, magnetic, swivel bracket
Installation Method
Immersion installation
Measuring Principle
Platinum electrode method
Measuring Range
-1500~+1500mV
Modulation
LoRa/FSK (Note: You can choose one of them)
Operating Humidity Range
<90%RH (No condensation)
Operating Temperature
-20°C ~ 55°C
Operating Voltage
12 VDC to 24 VDC
Operating Water Temperature Range
0 °C to +65°C
Operation Conditions
0 to 50℃ ≤0.2MPa
ORP Sensor
-1500 ~ +1500mV
pH Range
0 to 14PH
PH Resolution
0.01 pH
PH Value Accuracy
-0.3pH to + 0.3 pH
PH Value Range
0 to 14pH
Power consumption
0.2W@12V
Power supply
DC 12V
Protection Level
IP68
Receiving Sensitivity
–123 dBm for 2-FSK (at 1.2 Kbit/s),; –148 dBm for LoRa® (at 10.4 kHz, SF=12)
Resolution
1mV
RX Sensitivity
–123 dBm for 2-FSK (at 1.2 Kbit/s), –148 dBm for LoRa® (at 10.4 kHz, SF= 12)
Signal Output
RS-485 (Modbus/RTU)
Storage Temperature
-40°C ~ 85°C
Supportable LoRaWAN Band
EU863-870,US902-928,AU915-928,KR920-923,AS923-1,AS923-2,AS923-3,; IN865-867,CN470-510; (Note: The frequency band is optional and needs to be configured before shipment)
< 200 mA (connected pH, turbidity, and residual chlorine sensors)
Water Temperature Range (Included with pH Sensor)
0 to 65°C
Integration
Points to check before using R900PD05AO1 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -20℃ to +55℃ — check it against the installation environment.
2Thermalrated operating range -20°C ~ 55°C — check it against the installation environment.
< 200 mA (connected pH, turbidity, and residual chlorine sensors)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -20℃ to +55℃ — check it against the installation environment.
Thermal : rated operating range -20°C ~ 55°C — check it against the installation environment.
Applications and use cases
Architectures in which R900PD05AO1 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for R900PD05AO1 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.