R900PD05AO1 – LoRaWAN water pH, ORP and temperature sensor

LoRaWAN water pH, ORP and temperature sensor

Environmental Sensor Nodes

  • -20℃ to +55℃
  • -20°C ~ 55°C
  • 0 °C to +65°C
  • 0 to 65°C
Manufacturer part number
R900PD05AO1
Manufacturer
Netvox
Operating Temperature
-20°C ~ 55°C
Usable Pressure Range
<0.2MPa

Netvox R900PD05AO1 wireless sensor measuring water pH, oxidation-reduction potential (ORP) and temperature, with RS-485 Modbus/RTU output and LoRaWAN communication.

Product overview

Overview. The Netvox R900PD05AO1 is a LoRaWAN water pH, ORP and temperature sensor with a 3.3V digital output. It measures pH from 0 to 14 pH with 0.01 pH resolution and ORP from -1500 to +1500mV by platinum electrode method.

Main characteristics. ORP accuracy is ±20mV with 1mV resolution. pH accuracy is -0.3 to +0.3 pH. Temperature compensation is automatic (NTC) and calibration is one-point. Response time is below 30 s.

Interfaces and connectivity. The probe connects through a 1m cable over RS-485 (Modbus/RTU). The module communicates over LoRaWAN® Class C with LoRa or FSK modulation on the EU863-870, US902-928, AU915-928, KR920-923, AS923-1, AS923-2, AS923-3, IN865-867 and CN470-510 bands, configured before shipment. Range reaches 10 km line of sight and depends on the environment. The antenna is built in.

Power and environment. Operating voltage 12 VDC to 24 VDC, power consumption 0.2W at 12V. The probe is rated IP68, operates in water from 0°C to +65°C and the unit from 0°C to 50°C at pressure below 0.2MPa. The ABS/PC alloy housing measures 115.5 x 60 x 54 mm and operates from -20°C to +55°C.

Typical uses and integration. The immersion probe suits water quality monitoring. The RS-485 Modbus/RTU output allows connection to a PLC or gateway. Mounting by screws, double-sided tape or bracket, with optional DIN rail, magnetic or swivel bracket.

See all specifications

Highlights

  • Dimensions: L: 115.57mm x W: 60mm x H: 54.19mm
  • Response time: <30 s
  • Accuracy: ±20mV
  • Ambient Humidity: <90%RH (no condensation)
  • Ambient Operating Temperature: -20℃ to +55℃
  • Ambient Storage Temperature: -40℃ to +85℃

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -20℃ to +55℃ — check it against the installation environment.
  • Thermal: rated operating range -20°C ~ 55°C — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.