Netvox ZB01 ZigBee infrared motion detector for indoor presence detection, designed to be mounted at 2.5 m. It communicates over IEEE 802.15.4 and ZigBee Pro in the 2.4 GHz band.
Communication RangeUp to 50 meters indoor
ConsumptionTx 38mA / Rx 38mA
Frequency2.4-2.4835 GHz
Detection ModePassive Infrared
Initiation Time1 minute
Installation Height2.5 meters
Product overview
Overview. The Netvox ZB01 is a ZigBee wireless infrared motion detector, listed under environmental sensor nodes. It detects presence by passive infrared and reports events over the ZigBee network, using the ZigBee HA protocol with IAS Zone and On Off Light Switch device types.
Detection. Passive Infrared detection with coverage of 4 to 12 m at room temperature, a 120° horizontal and 60° vertical angle. It is designed for installation at 2.5 m height, with an initiation time of one minute.
Connectivity. IEEE 802.15.4 / ZigBee Pro protocol on 2.4 to 2.4835 GHz, with a communication range of up to 50 m indoors. Consumption of 38 mA in transmission and in reception.
Power and environment. Powered by 2 x 3 V CR123A batteries or a 12 V DC supply. Operating temperature from −10 to 50 °C, maximum humidity 95 % RH. Dimensions 80 × 60 × 34 mm.
Integration. It pairs with CIE devices (ZigBee security control panels) and fits into existing ZigBee networks.
Netvox ZB01 ZigBee infrared motion detector for indoor presence detection, designed to be mounted at 2.5 m. It communicates over IEEE 802.15.4 and ZigBee Pro in the 2.4 GHz band.
Communication RangeUp to 50 meters indoor
ConsumptionTx 38mA / Rx 38mA
Frequency2.4-2.4835 GHz
Detection ModePassive Infrared
Initiation Time1 minute
2. Datasheet extract (recorded values)
Parameter
Value
Communication Range
Up to 50 meters indoor
Consumption
Tx 38mA / Rx 38mA
Detection Coverage
4~12m@room temp, Horiz 120 deg, Ver 60deg
Detection Mode
Passive Infrared
Frequency
2.4-2.4835 GHz
Initiation Time
1 minute
Installation Height
2.5 meters
Operating Ambient
Temperature -10~50℃
Power supply
2 x 3V CR123A batteries
Product Dimension
80mm×60mm×34mm
Protocol
IEEE 802.15.4 / ZigBee Pro
Applications and use cases
Architectures in which ZB01 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for ZB01 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details