The Netvox ZL01E is a wireless environmental sensor node with an external rod antenna, operating in the 2.4 to 2.4835 GHz band to transmit measurement data.
Operating Temperature-10°C to 50°C
Overall quiescent current11mA
Working current400mA (maximum)
Frequency Bandwidth2.4 to 2.4835 GHz
Storage Temperature-40°C to 85 °C
Antenna TypeExternal rod antenna
Product overview
Overview. The Netvox ZL01E is an environmental sensor node from Netvox, part of the Environmental Sensor Nodes category, designed for radio communication in the 2.4 to 2.4835 GHz ISM band.
Main characteristics. The module uses DSSS (O-QPSK) modulation with a data transfer rate of 250 Kbps, a receiving sensitivity of -101 dBm and 16 communication channels (ISM channels 11 to 26). Power output reaches 7 dBm / 19 dBm at maximum depending on the module.
Connectivity. An external rod antenna provides the wireless link. The communication distance is 150 m / 800 m depending on the module used in the different models.
Power and environment. The ZL01E operates from a +5 VDC power source, with a maximum working current of 400 mA and an overall quiescent current of 11 mA. Its operating temperature range is -10 °C to 50 °C and its storage temperature range is -40 °C to 85 °C. The casing measures 110 mm x 55 mm x 20 mm.
Typical use. This node is intended for transmitting environmental measurement data over 2.4 GHz wireless networks, available on quotation from Atlas Electronics.
The Netvox ZL01E is a wireless environmental sensor node with an external rod antenna, operating in the 2.4 to 2.4835 GHz band to transmit measurement data.
Operating Temperature-10°C to 50°C
Overall quiescent current11mA
Working current400mA (maximum)
Frequency Bandwidth2.4 to 2.4835 GHz
Storage Temperature-40°C to 85 °C
2. Datasheet extract (recorded values)
Parameter
Value
Antenna Type
External rod antenna
Communication Channel
16 (ISM 11th to 26th channels)
Communication Distance
150 m / 800 m (depending on the module used in different models)
Data Transfer Rate
250Kbps
Frequency Bandwidth
2.4 to 2.4835 GHz
Main unit casing size
110 mm x 55 mm x 20 mm
Modulation system mode
DSSS (O-QPSK)
Operating Temperature
-10°C to 50°C
Overall quiescent current
11mA
Power Output
7 dBm /19dBm (maximum)
Receiving Sensitivity
-101 dBm
Storage Temperature
-40°C to 85 °C
Working current
400mA (maximum)
Working power source
+5VDC
Integration
Points to check before using ZL01E in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -10°C to 50°C — check it against the installation environment.
Power and communication
Overall quiescent current
11mA
Power Output
7 dBm /19dBm (maximum)
Working current
400mA (maximum)
Working power source
+5VDC
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -10°C to 50°C — check it against the installation environment.
Applications and use cases
Architectures in which ZL01E can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for ZL01E and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productNetvox
ZL01E
2.4 GHz environmental sensor node with external antenna
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details