ONLINE-FLUORESCENCE-DISSOLVED-OXYGEN-SENSOR
Online Fluorescence Dissolved Oxygen Sensor

- Power consumption
- <0.3 W at 12 V
- Storage Temperature
- -5~65℃
- Accuracy
- ±2% F.S., ±0.3℃
- Cable Length
- 5 meters, other lengths customizable
Online Fluorescence Dissolved Oxygen Sensor
Immersion fluorescence probe for continuous dissolved oxygen monitoring in water, with RS-485 Modbus RTU output and automatic temperature compensation.
Overview. The Niubol NBL-WQ-DO is an online fluorescence dissolved oxygen sensor designed for immersion and continuous water quality monitoring. It measures from 0 to 20.00 mg/L, equivalent to 0 to 200% saturation at 25 degrees C.
Main characteristics. Accuracy is ±2% F.S. and ±0.3℃, with a resolution of 0.01 mg/L and 0.1℃. The measuring principle is fluorescence, with two-point calibration and automatic temperature compensation using a Pt1000. Salinity compensation is configurable and relies on an entered value, not an independent measurement.
Interfaces and connectivity. The sensor provides an RS-485 Modbus RTU output and a 5-meter cable, other lengths being customizable. It installs with a 3/4" NPT thread.
Power and environment. Power supply is 12~24 VDC, with power consumption below 0.3 W at 12 V. It operates from 0 to 45 degrees C at a pressure below 0.2 MPa and stores between -5 and 65℃. The housing is made of POM and 316L stainless steel, with protection rating IP68.
Typical uses. The sensor suits continuous dissolved oxygen monitoring in water where its range and accuracy match the process. The optical principle does not consume oxygen and requires no electrolyte.
Maintenance. The replaceable fluorescent cap is recommended for annual replacement under normal use. Damage checks and sensor rinsing are scheduled every 30 days.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for ONLINE-FLUORESCENCE-DISSOLVED-OXYGEN-SENSOR, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | ±2% F.S., ±0.3℃ |
| Cable Length | 5 meters, other lengths customizable |
| Calibrate sensors (if required by competent authority) | According to the maintenance schedule required by the competent department |
| Calibration | Two-point calibration |
| Check for damage to sensors and fluorescent caps | Check every 30 days |
| Installation Method | Immersion installation, 3/4" NPT thread |
| Maintenance task | Recommended Maintenance Frequency |
| Measuring Principle | Fluorescence Method |
| Measuring Range | 0-20.00 mg/L (0-200% saturation at 25 degrees C) |
| Model | NBL-WQ-DO |
| Operating Conditions | 0-45 degrees C; pressure <0.2 MPa |
| Output mode | RS-485 Modbus- RTU |
| Power consumption | <0.3 W at 12 V |
| Power supply | 12~24 VDC |
| Products | Weather Stations |
| Protection rating | IP68 |
| Replace fluorescent cap | Replace once a year |
| Resolution | 0.01 mg/L, 0.1℃ |
| Sensor cleaning | Rinse every 30 days |
| Sensor housing material | POM and 316L stainless steel |
| Service Life of Fluorescent Cap | Annual replacement recommended under normal use; inspect condition during service |
| Storage Temperature | -5~65℃ |
| Temperature Compensation | Automatic Temperature Compensation (Pt1000) |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for ONLINE-FLUORESCENCE-DISSOLVED-OXYGEN-SENSOR. For a missing document or a specific revision, our experts send it to you.
Immersion fluorescence probe for continuous dissolved oxygen monitoring in water, with RS-485 Modbus RTU output and automatic temperature compensation.
| Parameter | Value |
|---|---|
| Accuracy | ±2% F.S., ±0.3℃ |
| Cable Length | 5 meters, other lengths customizable |
| Calibrate sensors (if required by competent authority) | According to the maintenance schedule required by the competent department |
| Calibration | Two-point calibration |
| Check for damage to sensors and fluorescent caps | Check every 30 days |
| Installation Method | Immersion installation, 3/4" NPT thread |
| Maintenance task | Recommended Maintenance Frequency |
| Measuring Principle | Fluorescence Method |
| Measuring Range | 0-20.00 mg/L (0-200% saturation at 25 degrees C) |
| Model | NBL-WQ-DO |
| Operating Conditions | 0-45 degrees C; pressure <0.2 MPa |
| Output mode | RS-485 Modbus- RTU |
| Power consumption | <0.3 W at 12 V |
| Power supply | 12~24 VDC |
| Products | Weather Stations |
| Protection rating | IP68 |
| Replace fluorescent cap | Replace once a year |
| Resolution | 0.01 mg/L, 0.1℃ |
| Sensor cleaning | Rinse every 30 days |
| Sensor housing material | POM and 316L stainless steel |
| Service Life of Fluorescent Cap | Annual replacement recommended under normal use; inspect condition during service |
| Storage Temperature | -5~65℃ |
| Temperature Compensation | Automatic Temperature Compensation (Pt1000) |
Answers to the questions that the recorded characteristics of ONLINE-FLUORESCENCE-DISSOLVED-OXYGEN-SENSOR can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Output mode": RS-485 Modbus- RTU.
Yes — recorded under "Output mode": RS-485 Modbus- RTU.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Online Fluorescence Dissolved Oxygen Sensor

NBL-WQ-DO-4S Online Fluorescence Dissolved Oxygen Sensor: For Wastewater Treatment and Aquaculture Online Monitoring

SUP-DO7013 Electrochemical dissolved oxygen sensor

SUP-DO7017 Optical dissolved oxygen sensor

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | ONLINE-FLUORESCENCE-DISSOLVED-OXYGEN-SENSOR |
| Manufacturer | Niubol |
Oxygen Sensors
Fluorescence dissolved oxygen sensor with RS-485 and 4-20mA · Ref. : WQ-DO-4A
Price on request
Oxygen Sensors
Drinking Water Dissolved Oxygen Sensor Probe
Price on request
Oxygen Sensors
Wall-Mounted Oxygen Transmitter with RS485 Output
Price on request
Oxygen Sensors
Industrial dissolved oxygen sensor, 0-20 mg/L range · Ref. : DOG-209FA
Price on request