19879854-00
Insertion electromagnetic flow meter, 316L electrodes

- Accuracy
- 1.0%FS,1.5%FS
- Certification
- Explosion-proof certificate
- Display
- LCD
- Lining
- ABS, PTFE
Insertion electromagnetic flow meter, 316L electrodes
Insertion electromagnetic flow meter measuring the volume flow of conductive liquids and slurries in closed pipes, with ABS and PTFE lining and 316SS body.
Nuoying NYLD-CR. insertion electromagnetic flow meter for conductive liquids. The NYLD-CR is an insertion electromagnetic flow meter designed to measure the volume flow of conductive liquids and slurries in closed pipes.
Measuring principle. The measurement is based on Faraday's law of electromagnetic induction. A coil creates the working magnetic field and the voltage induced on the electrodes, proportional to the average fluid velocity, is amplified and processed by the transmitter.
Main characteristics. Accuracy of 1.0%FS or 1.5%FS, LCD display, pipe sizes from DN100 to DN3000, medium temperature from -30 to 180 ℃, ambient temperature from -25 to 80 ℃, pressure from 0.6 to 1.6 MPa.
Materials. 316SS body, ABS and PTFE lining, electrodes in 316L, titanium, tantalum, platinum-iridium alloy, Hastelloy B and Hastelloy C, suitable for corrosive liquids.
Outputs and communication. 4-20 mA, pulse, frequency, RS485, Modbus and HART outputs, allowing integration into a PLC or a supervision system.
Power and protection. Power supply 85 to 265 VAC, 24 VDC or 3.6 V battery, protection level IP65, IP67 and IP68, explosion-proof certificate.
Typical uses. Water, sewage, sea water and acid liquids in water and wastewater networks, chemical, metallurgy or food industries.
Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 19879854-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accuracy | 1.0%FS,1.5%FS |
| Certification | Explosion-proof certificate |
| Display | LCD |
| Electrode material | 316L, titanium, tantalum, platinum-iridium alloy, Hastelloy B, Hastelloy C |
| Lining | ABS, PTFE |
| Material | 316SS |
| Medium | Liquid;water;sewage Water;sea Water;acid Water; |
| Medium temperature | -30~180℃ |
| Model Number | NYLD-CR |
| Output | 4-20MA, pulse, frequency, RS485, MODBUS, HART |
| Pipe size | DN100-DN3000 |
| Power supply | 85~265VAC,24V DC,3.6VBattery powered |
| Pressure | 0.6~1.6MPa |
| Protection Level | IP65,IP67,IP68 |
| Temperature | -25~80℃ |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 19879854-00. For a missing document or a specific revision, our experts send it to you.
Insertion electromagnetic flow meter measuring the volume flow of conductive liquids and slurries in closed pipes, with ABS and PTFE lining and 316SS body.
| Parameter | Value |
|---|---|
| Accuracy | 1.0%FS,1.5%FS |
| Certification | Explosion-proof certificate |
| Display | LCD |
| Electrode material | 316L, titanium, tantalum, platinum-iridium alloy, Hastelloy B, Hastelloy C |
| Lining | ABS, PTFE |
| Material | 316SS |
| Medium | Liquid;water;sewage Water;sea Water;acid Water; |
| Medium temperature | -30~180℃ |
| Model Number | NYLD-CR |
| Output | 4-20MA, pulse, frequency, RS485, MODBUS, HART |
| Pipe size | DN100-DN3000 |
| Power supply | 85~265VAC,24V DC,3.6VBattery powered |
| Pressure | 0.6~1.6MPa |
| Protection Level | IP65,IP67,IP68 |
| Temperature | -25~80℃ |
Answers to the questions that the recorded characteristics of 19879854-00 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Output": 4-20MA, pulse, frequency, RS485, MODBUS, HART.
Yes — recorded under "Output": 4-20MA, pulse, frequency, RS485, MODBUS, HART.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Insertion electromagnetic flow meter, 316L electrodes

IP68 Intelligent Electromagnetic Flow Meter 0.1-10m/S 4-20mA

NYLD Tubular Electromagnetic Flow Meter High Reliability Modbus Protocol

1Mpa 2.5Mpa 4Mpa Electromagnetic Flow Transmitter 15mm To 800mm

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 19879854-00 |
| Manufacturer | Nuoying |
Electromagnetic Flow Meters
Insertion Electromagnetic Flowmeter
Price on request
Electromagnetic Flow Meters
Intelligent Electromagnetic Flowmeter DN10 to DN2000 · Ref. : AF-EMF89
Price on request
Electromagnetic Flow Meters
DN25 to DN400 Electromagnetic Heat Flowmeter · Ref. : MFE600H
Price on request
Electromagnetic Flow Meters
Electromagnetic flow meter
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details