20012963-00
Sanitary Electromagnetic Flow Meter RS485 316L

- Certification
- Explosion-proof certificate,CE
- Ex-proof Mark
- Exd IIBT4
- Liner Material:
- PTFE/PFA/F46/Neoprene/Polyurethane
- Main power
- AC220V 50HZ / DC24V
Sanitary Electromagnetic Flow Meter RS485 316L
Nuoying NYLL-GB sanitary electromagnetic flow meter for measuring the volumetric flow of conductive liquids, syrups and food products in closed conduits, with 4-20 mA, RS485 and pulse outputs.
Overview. The Nuoying NYLL-GB is a sanitary electromagnetic flow meter for measuring the volumetric flow of conductive liquids and slurries in closed conduits. It is intended for liquids such as water, milk, juice, drinks, molasses, honey and soy sauce.
Main characteristics. Accuracy of ±0.5% of the displayed value, with ±0.3% or ±0.2% selectable. Large backlit LCD display showing instantaneous flow, total flow, percentage of flow and alarms, with four thin-film touch buttons for setup. Damping time constant adjustable from 0 to 100 s. Forward and reverse totalizers. Anti-failure clock storing 16 power failure records over 10 years.
Interfaces and connectivity. Isolated 4-20 mA or 0-10 mA analog output, RS485 with Modbus, HART or Profibus DP protocols, frequency output from 1 to 5000 Hz and pulse output up to 5000 CP/S, plus two alarm outputs from photoelectric isolated transistors, limited to 35 V and 250 mA. Alarms signal an empty pipe, a broken excitation circuit or a flow rate beyond the set limits.
Power and environment. AC 220 V 50 Hz or DC 24 V supply, power consumption below 15 W, IP65 protection class. Explosion-proof certification Exd IIBT4 and CE marking.
Construction and integration. 316L stainless steel body with PTFE, PFA, F46, neoprene or polyurethane liner depending on the fluid. The Modbus and RS485 protocols allow connection to a PLC or a supervision system.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 20012963-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Accumulator | Forward total quantity,reverse total quantity |
| Accuracy | ±0.5% of the value displayed,±0.3% or ±0.2% are selectable. |
| Certification | Explosion-proof certificate,CE |
| Communication | RS232,RS485 or HART Communication are selectable,with lighting resistance |
| Damping time constant | Continuous variable from 0-100 s (90%)can be selected by group |
| Display and push buttons | The big screen LCD display with back lighting can display the instantaneous flow,total flow and percentage of flow as well as alarm display,four thin-film touch nubs,which is used to data set. |
| Ex-proof Mark | Exd IIBT4 |
| Liner Material: | PTFE/PFA/F46/Neoprene/Polyurethane |
| Main power | AC220V 50HZ / DC24V |
| Material | Stainless Steel/304ss/316L |
| Medium | Liquid;molasses;milk;juice;drink Water;honey |
| Model Number | NYLL-GB |
| Output | 4-20mA/RS485/pulse/ Frequency |
| Output signal — Alarm output | Two outputs from the collectors of photoelectric isolate transistors are for alarm signals.The external voltage must be lower than 35V and the max output current is 250Ma when the transistor is turned on.Alarm status:Activates when the measured pipes are empty,the excitation circuits are broken or the volume of flow rate exceeds the value designed limits. |
| Output signal — Analog; output | Bi-direction with two ways,Isolation 0-10mA/4-20mA |
| Output signal — Frequency output | Forward & reverse flow output with frequency range set between 1-5000Hz.The external voltage must be lower than 35V and the max output and the max output current is 50Ma when the transistor is turned on |
| Output signal — Pulse output | For pulse output in forward and reverse flow measurement,upper frequency of pulse output can be up to 5000 CP/S relevant value of pulse is from 0.0001 to 1.0 M3/P.The width of pulse can be set to 20ms or squired wave from automatically.The collector of transistor with photoelectric is open circuited.The external voltage must be lower than 35 V and maximum output current is 250Ma when the transistor is turned on. |
| Power consumption | <15W (And set with sensor supporting power consumption ) |
| Power failure | An anti-failure clock is designed in the flow meter which can save the power failure records for 16 times (10 years) |
| Protection Class | IP65 |
| Protocol | Modbus/Hart/Profibus DP |
| Type | Variable Area Water Flowmeters |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 20012963-00. For a missing document or a specific revision, our experts send it to you.
Nuoying NYLL-GB sanitary electromagnetic flow meter for measuring the volumetric flow of conductive liquids, syrups and food products in closed conduits, with 4-20 mA, RS485 and pulse outputs.
| Parameter | Value |
|---|---|
| Accumulator | Forward total quantity,reverse total quantity |
| Accuracy | ±0.5% of the value displayed,±0.3% or ±0.2% are selectable. |
| Certification | Explosion-proof certificate,CE |
| Communication | RS232,RS485 or HART Communication are selectable,with lighting resistance |
| Damping time constant | Continuous variable from 0-100 s (90%)can be selected by group |
| Display and push buttons | The big screen LCD display with back lighting can display the instantaneous flow,total flow and percentage of flow as well as alarm display,four thin-film touch nubs,which is used to data set. |
| Ex-proof Mark | Exd IIBT4 |
| Liner Material: | PTFE/PFA/F46/Neoprene/Polyurethane |
| Main power | AC220V 50HZ / DC24V |
| Material | Stainless Steel/304ss/316L |
| Medium | Liquid;molasses;milk;juice;drink Water;honey |
| Model Number | NYLL-GB |
| Output | 4-20mA/RS485/pulse/ Frequency |
| Output signal — Alarm output | Two outputs from the collectors of photoelectric isolate transistors are for alarm signals.The external voltage must be lower than 35V and the max output current is 250Ma when the transistor is turned on.Alarm status:Activates when the measured pipes are empty,the excitation circuits are broken or the volume of flow rate exceeds the value designed limits. |
| Output signal — Analog; output | Bi-direction with two ways,Isolation 0-10mA/4-20mA |
| Output signal — Frequency output | Forward & reverse flow output with frequency range set between 1-5000Hz.The external voltage must be lower than 35V and the max output and the max output current is 50Ma when the transistor is turned on |
| Output signal — Pulse output | For pulse output in forward and reverse flow measurement,upper frequency of pulse output can be up to 5000 CP/S relevant value of pulse is from 0.0001 to 1.0 M3/P.The width of pulse can be set to 20ms or squired wave from automatically.The collector of transistor with photoelectric is open circuited.The external voltage must be lower than 35 V and maximum output current is 250Ma when the transistor is turned on. |
| Power consumption | <15W (And set with sensor supporting power consumption ) |
| Power failure | An anti-failure clock is designed in the flow meter which can save the power failure records for 16 times (10 years) |
| Protection Class | IP65 |
| Protocol | Modbus/Hart/Profibus DP |
| Type | Variable Area Water Flowmeters |
Answers to the questions that the recorded characteristics of 20012963-00 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication": RS232,RS485 or HART Communication are selectable,with lighting resistance.
Yes — recorded under "Communication": RS232,RS485 or HART Communication are selectable,with lighting resistance.
Yes — recorded under "Damping time constant": Continuous variable from 0-100 s (90%)can be selected by group.
Yes — recorded under "Protocol": Modbus/Hart/Profibus DP.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Sanitary Electromagnetic Flow Meter RS485 316L

FMC240 Electromagnetic Flowmeter Measuring Tap Water

FMX300 Compact Electromagnetic Flowmeter for Data Center

FMX400 Compact Electromagnetic Flowmeter

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 20012963-00 |
| Manufacturer | Nuoying |
Electromagnetic Flow Meters
Insertion Electromagnetic Flowmeter
Price on request
Electromagnetic Flow Meters
Intelligent Electromagnetic Flowmeter DN10 to DN2000 · Ref. : AF-EMF89
Price on request
Electromagnetic Flow Meters
DN25 to DN400 Electromagnetic Heat Flowmeter · Ref. : MFE600H
Price on request
Electromagnetic Flow Meters
Electromagnetic flow meter
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details