NYLD-CR – Insertion electromagnetic flow meter for water and liquids

Insertion electromagnetic flow meter for water and liquids

Electromagnetic Flow Meters

  • 0.1~10m/s
  • 6.5W
  • CE
  • 316L Stainless steel
Manufacturer part number
30744894-00
Manufacturer
Nuoying
Velocity range
0.1~10m/s
Power consumption
6.5W

NYLD-CR insertion electromagnetic flow meter for liquid flow measurement in pipes from 300 to 3000 mm in diameter, installable without stopping the water.

Product overview

Overview. The Nuoying NYLD-CR insertion electromagnetic flow meter, reference NYLD-CR, is an insertion electromagnetic flow meter designed for liquid flow measurement. It is developed from the pipeline electromagnetic flow meter and keeps its advantages while being installed on the pipe, which reduces installation difficulty and cost.

Main characteristics. The measuring principle is electromagnetic and applied to the average velocity of the fluid, the volumetric flow being derived from this measurement. The velocity range is 0.1 to 10 m/s, the pipe diameter 300 to 3000 mm and the pressure rating less than or equal to 1.6 MPa. The instrument provides automatic range switching, upper and lower limit alarms, an empty pipe alarm and a small signal cut function. An internal non-power-off clock stores 16 power-off events, and set parameters and accumulated values are saved in EEPROM after a power loss.

Connection and materials. Connection is by thread or by flange (optional). The electrodes are 316L stainless steel and the sensor is stainless steel. Straight pipe requirements are 5 DN upstream and 3 DN downstream.

Power and environment. The instrument is powered by AC220V 50Hz, DC24V or 3.6V, with a power consumption of 6.5 W. The 220 VAC supply tolerates 15 % variation and the 24 VDC supply ripple less than or equal to 5 %. Ambient humidity range is 5 to 100 % RH. Protection grade is IP65, IP67 or IP68 (optional), and the explosion-proof grades listed are ExiaIICT5Ga and ExdIICT5Gb, with the certificate giving details of conditions of use.

Typical uses. The instrument is intended for liquid flow measurement, including water, in large diameter pipes where installation without interrupting service is sought.

See all specifications

Highlights

  • Certification: CE
  • Connection Method: Thread,flange (optional)
  • Damping time constant: Continuous variable can be selected from 0~100s (90%) time binning
  • Electrode material: 316L Stainless steel
  • Environment Humidity: 5~100%RH (relative Humidity)
  • Explosion-proof grade: ExiaIICT5Ga, ExdIICT5Gb (see certificate for details)

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.