30742238-00
Pipeline electromagnetic flow meter for conductive liquids

- Measuring Range
- 1500:1 Flow Rate Is Set To <15m/s
- Power consumption
- <15W
- Ambient temperature
- -25℃~+60℃
- Certification
- CE
Pipeline electromagnetic flow meter for conductive liquids
Nuoying NYLD pipeline electromagnetic flow meter for measuring the volume flow of conductive liquids such as water, oil and gas liquids in closed pipes.
Overview. The Nuoying NYLD pipeline electromagnetic flow meter measures the volume flow of conductive liquids in closed pipes, for water, oil and process liquids.
Main characteristics. Measuring range 1500:1 with flow rate set to a maximum of 15 m/s, accuracy of ±0.5% of the displayed value, optionally ±0.3% or ±0.2%. Damping time constant adjustable from 0 to 100 s (90%). Dielectric conductivity of 20 µS/cm or more. Forward and reverse totalizers.
Interfaces and connectivity. Analog, frequency, alarm and pulse outputs. Optional RS232C or RS485 serial communication and HART protocol. Lightning protection with a 10-year record.
Power and environment. Power supply AC220V 50 Hz, DC24V or 3.6V. Power consumption below 15 W. Non-power-off internal clock storing 16 power interruptions. Ambient temperature -25 °C to +60 °C, relative humidity 5 to 100%. Protection grade IP65, IP67 or IP68 optional. CE certified.
Typical uses. Liquid flow measurement in pipes, for water, oil and gas applications as specified by the project.
Integration. The RS485 output and HART protocol allow connection to a PLC or a supervision system.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 30742238-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Ambient temperature | -25℃~+60℃ |
| Certification | CE |
| Communication Method | Optional RS232C or RS485 serial communication interface, HART communication protocol, with lightning protection record (10 years) |
| Counter | Forward total, reverse total |
| Damping time constant | Continuous variable can be selected from 0~100s (90%) time binning |
| Dielectric conductivity | ≥ 20µs/cm |
| Environment Humidity | 5~100%RH (relative humidity) |
| Matching accuracy | Plus or minus 0.5% of the displayed value, optional plus or minus 0.3% or 0.2% of the displayed value |
| Measuring Range | 1500:1 Flow Rate Is Set To <15m/s |
| Model Number | NYLD |
| Power consumption | <15W |
| Power loss protection | The instrument is designed with a non-power-off clock inside, which can store 16 power-off times |
| Power supply | AC220V 50Hz /DC24V/3.6V |
| Protection Grade | IP65, IP67,IP68 (optional) |
| Signal Output | Analog output, frequency output, alarm output, pulse output |
| Typical application | Liquid Flow Measurement In Pipes |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 30742238-00. For a missing document or a specific revision, our experts send it to you.
Nuoying NYLD pipeline electromagnetic flow meter for measuring the volume flow of conductive liquids such as water, oil and gas liquids in closed pipes.
| Parameter | Value |
|---|---|
| Ambient temperature | -25℃~+60℃ |
| Certification | CE |
| Communication Method | Optional RS232C or RS485 serial communication interface, HART communication protocol, with lightning protection record (10 years) |
| Counter | Forward total, reverse total |
| Damping time constant | Continuous variable can be selected from 0~100s (90%) time binning |
| Dielectric conductivity | ≥ 20µs/cm |
| Environment Humidity | 5~100%RH (relative humidity) |
| Matching accuracy | Plus or minus 0.5% of the displayed value, optional plus or minus 0.3% or 0.2% of the displayed value |
| Measuring Range | 1500:1 Flow Rate Is Set To <15m/s |
| Model Number | NYLD |
| Power consumption | <15W |
| Power loss protection | The instrument is designed with a non-power-off clock inside, which can store 16 power-off times |
| Power supply | AC220V 50Hz /DC24V/3.6V |
| Protection Grade | IP65, IP67,IP68 (optional) |
| Signal Output | Analog output, frequency output, alarm output, pulse output |
| Typical application | Liquid Flow Measurement In Pipes |
Answers to the questions that the recorded characteristics of 30742238-00 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication Method": Optional RS232C or RS485 serial communication interface, HART communication protocol, with lightning protection record (10 years).
Yes — recorded under "Damping time constant": Continuous variable can be selected from 0~100s (90%) time binning.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Pipeline electromagnetic flow meter for conductive liquids

Digital Water Liquid Electromagnetic Flow Meter High Precision

Insertion Electromagnetic Flow Meter Water Acid Alkali Alarm

High Accuracy And Reliability Pipeline Electromagnetic Flowmeter No Flow-Obstructing Parts

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 30742238-00 |
| Manufacturer | Nuoying |
Electromagnetic Flow Meters
Insertion Electromagnetic Flowmeter
Price on request
Electromagnetic Flow Meters
Intelligent Electromagnetic Flowmeter DN10 to DN2000 · Ref. : AF-EMF89
Price on request
Electromagnetic Flow Meters
DN25 to DN400 Electromagnetic Heat Flowmeter · Ref. : MFE600H
Price on request
Electromagnetic Flow Meters
Electromagnetic flow meter
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details