35742155-00
Pipeline electromagnetic flowmeter without flow-obstructing parts

- Measuring Range
- 1500:1 flow rate setting < 15m/s
- Power consumption
- < 15W
- Ambient Humidity
- 5~100%RH (relative humidity)
- Ambient temperature
- -25℃~+60℃
Pipeline electromagnetic flowmeter without flow-obstructing parts
Pipeline electromagnetic flowmeter for conductive liquids and slurries, with no flow-obstructing parts in the measuring pipe and frequency, alarm and pulse outputs.
Overview. The NYLD electromagnetic flowmeter from Nuoying measures the volume flow rate of conductive liquids and slurries in closed pipelines, based on Faraday's law of electromagnetic induction.
Main characteristics. Measuring range 1500:1 for a flow rate setting below 15 m/s, measuring accuracy 0.5% by default, 0.3% or 0.2% optional, matching accuracy ± 0.5% of the indicated value. Nominal diameters from DN6 mm to DN3000 mm, nominal pressure 0.6 to 4.0 MPa, special pressure can be customized. The measuring pipe has no flow-obstructing parts, so there is no pressure loss and low requirements for straight pipe sections.
Interfaces and connectivity. RS232C or RS485 serial communication interface, HART communication protocol, frequency, alarm and pulse outputs, positive and reverse totalizers. Parameters are set through infrared touch keys without opening the converter cover.
Power and environment. Power supply AC220V 50Hz or DC24V / 3.6V, power consumption below 15 W. Ambient temperature -25 °C to +60 °C, ambient humidity 5 to 100 %RH. Protection class IP65, IP67 or IP68 optional. Non-power-off clock storing 16 power-off events.
Typical uses. Measurement of conductive liquids and slurries in pipelines, with a choice of liner materials (polychloroprene rubber, polyurethane rubber, PTFE, PFA) and electrode materials suited to the fluid.
Integration. All-in-one, split, immersed or explosion-proof structures. CE certified. Explosion-proof class Exia IICT5 Ga and ExdICT5 Gb per certificate.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 35742155-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Ambient Humidity | 5~100%RH (relative humidity) |
| Ambient temperature | -25℃~+60℃ |
| Certification | CE |
| Communication mode | RS232C or RS485 serial communication interface, HART communication protocol, with lightning protection record (10 years) |
| Counter | Total positive, Total Reverse |
| Damping Time: | constant Continuous variable is selectable from 0~100s (90%) |
| Dielectric conductivity | ≥ 20us/cm |
| Electrode forms | standard, scraper and replaceable form |
| Electrode material | 16, Hastelloy B, Hastelloy C, titanium, tantalum, platinum/iridium alloy, stainless steel coated tungsten carbide |
| EXPLOSION PROOF CLASS | Exia IICT5 Ga, ExdICT5 Gb (see certificate for details) |
| lining material | polychloroprene rubber, polyurethane rubber, silicone fluororubber, PTFE, perfluoroethylene propylene (F46) and PFA |
| Matching accuracy | ± 0.5% of the indicated value, ± 0.3% or 0.2% of the indicated value can be selected |
| Measuring Accuracy | 0.5% default setting, 0.3% or 0.2% optional |
| Measuring Range | 1500:1 flow rate setting < 15m/s |
| Medium temperature | Integrated type |
| Model Number | NYLD |
| Nominal diameter | DN6mm-DN3000mm |
| NOMINAL PRESSURE | 0.6~4.0MPa (special pressure can be customized) |
| Output signal | frequency, alarm and pulse output |
| Power consumption | < 15W |
| Power-off protection | Internally designed with a non-power-off clock, which can store 16 power-off times |
| Power supply | AC220V50Hz/DC24V/3.6V |
| Product Model | NYLD |
| Protection Class | IP65, IP67, IP68 (optional) |
| Structural type | all-in-one, split, immersed, explosion-proof |
| Typical application | Conductive Liquid And Slurry |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 35742155-00. For a missing document or a specific revision, our experts send it to you.
Pipeline electromagnetic flowmeter for conductive liquids and slurries, with no flow-obstructing parts in the measuring pipe and frequency, alarm and pulse outputs.
| Parameter | Value |
|---|---|
| Ambient Humidity | 5~100%RH (relative humidity) |
| Ambient temperature | -25℃~+60℃ |
| Certification | CE |
| Communication mode | RS232C or RS485 serial communication interface, HART communication protocol, with lightning protection record (10 years) |
| Counter | Total positive, Total Reverse |
| Damping Time: | constant Continuous variable is selectable from 0~100s (90%) |
| Dielectric conductivity | ≥ 20us/cm |
| Electrode forms | standard, scraper and replaceable form |
| Electrode material | 16, Hastelloy B, Hastelloy C, titanium, tantalum, platinum/iridium alloy, stainless steel coated tungsten carbide |
| EXPLOSION PROOF CLASS | Exia IICT5 Ga, ExdICT5 Gb (see certificate for details) |
| lining material | polychloroprene rubber, polyurethane rubber, silicone fluororubber, PTFE, perfluoroethylene propylene (F46) and PFA |
| Matching accuracy | ± 0.5% of the indicated value, ± 0.3% or 0.2% of the indicated value can be selected |
| Measuring Accuracy | 0.5% default setting, 0.3% or 0.2% optional |
| Measuring Range | 1500:1 flow rate setting < 15m/s |
| Medium temperature | Integrated type |
| Model Number | NYLD |
| Nominal diameter | DN6mm-DN3000mm |
| NOMINAL PRESSURE | 0.6~4.0MPa (special pressure can be customized) |
| Output signal | frequency, alarm and pulse output |
| Power consumption | < 15W |
| Power-off protection | Internally designed with a non-power-off clock, which can store 16 power-off times |
| Power supply | AC220V50Hz/DC24V/3.6V |
| Product Model | NYLD |
| Protection Class | IP65, IP67, IP68 (optional) |
| Structural type | all-in-one, split, immersed, explosion-proof |
| Typical application | Conductive Liquid And Slurry |
Answers to the questions that the recorded characteristics of 35742155-00 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Communication mode": RS232C or RS485 serial communication interface, HART communication protocol, with lightning protection record (10 years).
Yes — recorded under "Matching accuracy": ± 0.5% of the indicated value, ± 0.3% or 0.2% of the indicated value can be selected.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Pipeline electromagnetic flowmeter without flow-obstructing parts

Digital Water Liquid Electromagnetic Flow Meter High Precision

Digital Pipeline Electromagnetic Flow Meter For Water Oil Gas Liquid

Insertion Type Electromagnetic Flow Meter Upper Empty Alarm AC220V

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 35742155-00 |
| Manufacturer | Nuoying |
Electromagnetic Flow Meters
Insertion Electromagnetic Flowmeter
Price on request
Electromagnetic Flow Meters
Intelligent Electromagnetic Flowmeter DN10 to DN2000 · Ref. : AF-EMF89
Price on request
Electromagnetic Flow Meters
DN25 to DN400 Electromagnetic Heat Flowmeter · Ref. : MFE600H
Price on request
Electromagnetic Flow Meters
Electromagnetic flow meter
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details