NYLD-CR – Insertion Type Electromagnetic Flowmeter for Liquids with Limit Alarm

Insertion Type Electromagnetic Flowmeter for Liquids with Limit Alarm

Electromagnetic Flow Meters

  • 0.1~10m/s
  • Customized design
  • 5~100%RH
  • CE
Manufacturer part number
31206447-00
Manufacturer
Nuoying
Flow-rate range
0.1~10m/s
Measuring Range
Customized design

The NYLD-CR insertion type electromagnetic flowmeter measures the volume flow of conductive liquids in pipes from 300 to 3000 mm, with upper and lower limit alarms.

Product overview

NYLD-CR insertion type electromagnetic flowmeter — The NYLD-CR insertion type electromagnetic flowmeter from Nuoying is a liquid flow measurement instrument designed to be installed by insertion into a pipeline. It is intended for measuring liquid flow in pipes with a diameter between 300 and 3000 mm.

Working principle and installation. The sensor applies the Nikuradse principle: it measures the average flow velocity of the fluid by electromagnetic method, from which the volume flow rate is obtained. Its simple installation allows it to be fitted without stopping the flow, and opening under pressure is possible on site. It can be installed on cast iron or cement pipelines.

Main characteristics. Flow velocity range from 0.1 to 10 m/s, measuring range on customized design, and electrical conductivity greater than 50 µS/cm. The sensor is made of stainless steel, the pressure resistance is 1.6 MPa, and the process connection is by thread, with flange optional. The required straight pipe section is 5 DN upstream and 3 DN downstream.

Interfaces and communication. Outputs 4-20 mA, RS485, HART and MODBUS. The converter and the sensor are interchangeable.

Power and environment. Power supply AC220V 50Hz, DC24V or 3.6V. Ambient temperature from -20 °C to +60 °C, medium temperature from -20 °C to +130 °C, ambient humidity from 5 to 100 %RH. Protection level IP67, IP68 or IP65 optional. CE certification; explosion-proof grade Exia II CT5 Ga, Exd II CT5 Gb optional.

Typical uses. Liquid flow measurement on water, sewage and chemical fluid networks (water, sewage, acids and strong alkalis), particularly on supply and drainage pipelines. The RS485 and MODBUS output allows connection to a PLC or supervisory system.

Available on quotation from Atlas Electronics.

See all specifications

Highlights

  • Ambient Humidity: 5~100%RH
  • Certification: CE
  • Environment Temperature: -20℃~/+60℃
  • Explosion-proof grade: Exia II CT5 Ga, Exd II CT5 Gb(optional)
  • Flow-rate range: 0.1~10m/s
  • Measuring Range: Customized design

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote