Insertion Type Electromagnetic Flowmeter for Liquids with Limit Alarm

- Flow-rate range
- 0.1~10m/s
- Measuring Range
- Customized design
- Ambient Humidity
- 5~100%RH
- Certification
- CE
Insertion Type Electromagnetic Flowmeter for Liquids with Limit Alarm
The NYLD-CR insertion type electromagnetic flowmeter measures the volume flow of conductive liquids in pipes from 300 to 3000 mm, with upper and lower limit alarms.
NYLD-CR insertion type electromagnetic flowmeter — The NYLD-CR insertion type electromagnetic flowmeter from Nuoying is a liquid flow measurement instrument designed to be installed by insertion into a pipeline. It is intended for measuring liquid flow in pipes with a diameter between 300 and 3000 mm.
Working principle and installation. The sensor applies the Nikuradse principle: it measures the average flow velocity of the fluid by electromagnetic method, from which the volume flow rate is obtained. Its simple installation allows it to be fitted without stopping the flow, and opening under pressure is possible on site. It can be installed on cast iron or cement pipelines.
Main characteristics. Flow velocity range from 0.1 to 10 m/s, measuring range on customized design, and electrical conductivity greater than 50 µS/cm. The sensor is made of stainless steel, the pressure resistance is 1.6 MPa, and the process connection is by thread, with flange optional. The required straight pipe section is 5 DN upstream and 3 DN downstream.
Interfaces and communication. Outputs 4-20 mA, RS485, HART and MODBUS. The converter and the sensor are interchangeable.
Power and environment. Power supply AC220V 50Hz, DC24V or 3.6V. Ambient temperature from -20 °C to +60 °C, medium temperature from -20 °C to +130 °C, ambient humidity from 5 to 100 %RH. Protection level IP67, IP68 or IP65 optional. CE certification; explosion-proof grade Exia II CT5 Ga, Exd II CT5 Gb optional.
Typical uses. Liquid flow measurement on water, sewage and chemical fluid networks (water, sewage, acids and strong alkalis), particularly on supply and drainage pipelines. The RS485 and MODBUS output allows connection to a PLC or supervisory system.
Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 31206447-00, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Ambient Humidity | 5~100%RH |
| Certification | CE |
| Electrical conductivity | >50μ s/cm |
| Environment Temperature | -20℃~/+60℃ |
| Explosion-proof grade | Exia II CT5 Ga, Exd II CT5 Gb(optional) |
| Flow-rate range | 0.1~10m/s |
| Measuring Range | Customized design |
| Medium temperature | -20℃~/+130℃ |
| Model Number | NYLD-CR |
| Pipe Diameter | 300-3000mm |
| Power supply | AC220V 50Hz/DC24V/3.6V |
| Pressure Resistance | 1.6Mpa |
| Process Connection | Thread, flange(optional) |
| Protection Level | IP67,IP68,IP65(optional) |
| Sensor material | Stainless Steel |
| Signal Output | 4-20mA; RS485; HART; MODBUS |
| Straight pipe section | Front 5DN, rear 3DN |
| Typical application | liquid flow measurement |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 31206447-00. For a missing document or a specific revision, our experts send it to you.
The NYLD-CR insertion type electromagnetic flowmeter measures the volume flow of conductive liquids in pipes from 300 to 3000 mm, with upper and lower limit alarms.
| Parameter | Value |
|---|---|
| Ambient Humidity | 5~100%RH |
| Certification | CE |
| Electrical conductivity | >50μ s/cm |
| Environment Temperature | -20℃~/+60℃ |
| Explosion-proof grade | Exia II CT5 Ga, Exd II CT5 Gb(optional) |
| Flow-rate range | 0.1~10m/s |
| Measuring Range | Customized design |
| Medium temperature | -20℃~/+130℃ |
| Model Number | NYLD-CR |
| Pipe Diameter | 300-3000mm |
| Power supply | AC220V 50Hz/DC24V/3.6V |
| Pressure Resistance | 1.6Mpa |
| Process Connection | Thread, flange(optional) |
| Protection Level | IP67,IP68,IP65(optional) |
| Sensor material | Stainless Steel |
| Signal Output | 4-20mA; RS485; HART; MODBUS |
| Straight pipe section | Front 5DN, rear 3DN |
| Typical application | liquid flow measurement |
Answers to the questions that the recorded characteristics of 31206447-00 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "Signal Output": 4-20mA; RS485; HART; MODBUS.
Yes — recorded under "Signal Output": 4-20mA; RS485; HART; MODBUS.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Insertion Type Electromagnetic Flowmeter for Liquids with Limit Alarm

Digital Water Liquid Electromagnetic Flow Meter High Precision

Digital Pipeline Electromagnetic Flow Meter For Water Oil Gas Liquid

Insertion Type Electromagnetic Flow Meter Upper Empty Alarm AC220V

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 31206447-00 |
| Manufacturer | Nuoying |
Electromagnetic Flow Meters
Insertion Electromagnetic Flowmeter
Price on request
Electromagnetic Flow Meters
Intelligent Electromagnetic Flowmeter DN10 to DN2000 · Ref. : AF-EMF89
Price on request
Electromagnetic Flow Meters
DN25 to DN400 Electromagnetic Heat Flowmeter · Ref. : MFE600H
Price on request
Electromagnetic Flow Meters
Electromagnetic flow meter
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details