The Pilot SPM72 is a three-phase multifunction energy meter for monitoring consumption and energy management in low and medium voltage distribution installations.
Pilot SPM72. three-phase multifunction energy meter for AC panel. Electrical measurement — The SPM72 measures three-phase voltage and current, active, reactive and apparent power, power factor, frequency, phase angles and average values, as well as fundamental wave quantities. It provides bidirectional, per-phase and four-quadrant energy metering, with optional time-of-use (TOU) energy. Accuracy and advanced functions — Active energy class is D (L02) or C (L05), reactive energy class 0.5 (L02) or 1 (L05). Demand functions include real-time and predictive demand, with optional daily and monthly maximum demand. Power quality (optional) — Harmonic analysis up to the 63rd order, THD, TOHD, TEHD, zero-sequence and negative-sequence unbalance, current K-factor, voltage crest factor and current TDD. Data logging and alarms — 10-year and 12-month energy history, max/min parameter logging, optional 200 event records, and 15 alarm types including phase and line overvoltage and undervoltage, overcurrent, frequency, phase loss and phase sequence error. Inputs and outputs — Up to 4 digital inputs, optional 2 relay outputs, 1 optical pulse output as standard, optional electrical pulse output, up to 2 optional RS485 ports, optional 2 channels of 4~20 mA DC analog output and 4 optional temperature measurement channels. Rated current is configurable as 1 A or 5 A, and the meter is compatible with 3×57.7/100 V and 3×220/380 V systems. Communication and integration — The standard RS485 port supports Modbus RTU and DLT645 protocols for networked data acquisition, meter reading and automatic control by a supervisory system. The SPM72, the updated version of the SPM32, is suited to distribution systems below 650 kV, such as distribution cabinets and switchgear. Performance meets GB/T 17215.321-2021 for Class D active energy and GB/T 17215.324-2022 for Class 0.5S reactive energy. Immunity and safety — Power-frequency withstand voltage 3000 VAC, impulse voltage 6000 V, insulation resistance of 100 MΩ or more, Level 4 for electrostatic discharge, electrical fast transient and surge immunity, Level 3 for conducted and radiated RF immunity, and compliance with voltage dips, sags and interruptions immunity tests. Available on quotation from Atlas Electronics.
The Pilot SPM72 is a three-phase multifunction energy meter for monitoring consumption and energy management in low and medium voltage distribution installations.
0.2S Class Accuracy (Class D); Note 1:Not compatible with L02 option when rated current is 1A.
Measurement parameters
Measurement Parameters
Power Factor
0.2%
Power-frequency withstand voltage
3000VAC
Q
Power Quality Functions (Harmonic Analysis,Unbalance,Voltage Crest Factor,Current K-factor,Current TDD Function)
Rated Operating Parameters
Rated Operating Parameters
Reactive Energy
0.5 Class (L02); 1 Class (L05)
Reactive power
0.5% (L02); 1% (L05)
RF EM Field Rad. Immunity Test
Level 3
Surge Immunity Test
Level 4
Test Items
Performance / Severity Level
Unbalance
0.5%
Voltage Dips,Sags,Interruptions Immunity Test
Compliant
Applications and use cases
Architectures in which SPM72 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Solar production, storage and charging points on one site are often managed separately. Inverters, batteries, MPPT controllers, meters and chargers form a local energy system that shares production between users
To check
Regulatory framework for collective self-consumption in the country
Energy management system steering storage and charging
Metering accuracy for sharing between participants
Associated system blocks
ProductionStorageMeteringCharging
Need a complete solution?
Send a request for SPM72 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productPilot
SPM72
Three-phase multifunction energy meter for AC panel
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details