SPM73 – Three-Phase Multifunction Energy Meter for Panel Mounting

Three-Phase Multifunction Energy Meter for Panel Mounting

Three-Phase Energy Meters

  • -25 ℃~+60 ℃
  • CISPR22:2006,level B
  • IP54(Panel)
  • 250V AC/5A,30V DC/5A
Manufacturer part number
SPM73
Manufacturer
Pilot
Operating Temperature
-25 ℃~+60 ℃
Rated input voltage
3x 57.7/100V,3x 220/380V

Pilot SPM73 multifunction three-phase energy meter for high and low voltage distribution systems, installed in distribution panels and switchgear.

Product overview

Overview. The Pilot SPM73 three-phase energy meter is a multifunction panel meter designed for high and low voltage distribution systems. The manufacturer presents it as the updated version of the SPM33.

Main characteristics. The meter measures current through direct input from 5 mA to 6.5 A with 0.2% accuracy, and voltage through direct input from 10 to 400 V (L-N) or 10 to 690 V (L-L) with the same 0.2% accuracy. Frequency is measured from 40 to 70 Hz with 0.1% accuracy. Rated input current is configurable as 1(1.2) A or 5(6) A, and the rated input voltage is 3x 57.7/100 V or 3x 220/380 V. Q functions include power quality analysis, multi-tariff energy measurement, SOE recording and extreme value recording. Depending on the configuration, the display is a segmented LCD (L02, L05) or a dot-matrix LCD (B02, B05), with Class 0.2S or 0.5S accuracy for active energy; options B02 and B05 require option modules E4, E5 or E6, and L05 is the default configuration.

Interfaces and connectivity. The RS-485 port operates from 4800 to 19200 bps and supports the Modbus-RTU protocol, allowing data exchange with PLCs or SCADA supervisory systems. The relay outputs have a rated contact capacity of 250 V AC / 5 A and 30 V DC / 5 A.

Power and environment. The auxiliary supply accepts 85 to 275 V AC or 100 to 300 V DC. The meter operates between -25 °C and +60 °C and has an IP54 protection rating on the panel front.

Electromagnetic compatibility. Immunity to electrical fast transients (EFT/B, IEC 61000-4-4:2012, level 4), electrostatic discharge (ESD, IEC 61000-4-2:2008, level 4), surge (IEC 61000-4-5:2014, level 4) and radiated RF fields (IEC 61000-4-3:2010, level 3) meets the cited standards. Electromagnetic emission complies with CISPR22:2006, class B.

Typical uses. The SPM73 is installed in distribution panels, switchgear and other power distribution applications, where it enables centralized metering and automated control through a supervisory system.

See all specifications

Highlights

  • Direct Current Connection: 5mA to 6.5A,Accuracy 0.2%
  • ​ Direct Voltage Connection: 10 to 400V(L-N),10 to 690V(L-L),Accuracy 0.2%
  • EFT/B Immunity: IEC 61000-4-4:2012,level 4
  • EMI Emission: CISPR22:2006,level B
  • ESD Immunity: IEC 61000-4-2:2008,level 4
  • Frequency: 40 to 70Hz, Accuracy 0.1%

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -25 ℃~+60 ℃ — check it against the installation environment.