RAKwireless C15020 sensor hub for measuring nitrogen, phosphorus and potassium levels in soil, with LoRaWAN and NB-IoT communication in the EU868 band.
Measure range0 ~ 1999 mg/kg
Frequency bandEU868
Accuracy±2% FS
Response time<10 s
Baud rate2400/4800/9600
Communication portRS485
Product overview
Overview. The RAKwireless C15020 is an NPK soil sensor (Sensor Hub Soil NPK) that measures the nitrogen, phosphorus and potassium content of soil. It helps determine soil fertility and supports soil condition evaluation by the customer system.
Main characteristics. Measuring range of 0 to 1999 mg/kg, resolution of 1 mg/kg (mg/l), accuracy of ±2% FS and response time below 10 s.
Interfaces and connectivity. LoRaWAN+NB IoT variant, EU868 frequency band, RS485 communication port and baud rates of 2400, 4800 and 9600. A splitter cable connects several probes to a single Sensor Hub port, and an extension cable increases the distance between the Sensor Hub and the probe.
Power and environment. External 12 V to 24 V DC power supply included. Working temperature +5 to +45 ℃ and working humidity 5 to 95% RH, no condensation. The Sensor Hub with probe cannot be powered on batteries.
RAKwireless C15020 sensor hub for measuring nitrogen, phosphorus and potassium levels in soil, with LoRaWAN and NB-IoT communication in the EU868 band.
Measure range0 ~ 1999 mg/kg
Frequency bandEU868
Accuracy±2% FS
Response time<10 s
Baud rate2400/4800/9600
2. Datasheet extract (recorded values)
Parameter
Value
Frequency band
EU868
Response time
<10 s
Accuracy
±2% FS
Baud rate
2400/4800/9600
Communication port
RS485
Measure range
0 ~ 1999 mg/kg
Power supply
12 V ~ 24 V DC
Resolution
1 mg/kg (mg/l)
Variant
LoRaWAN+NB IoT
Working humidity
5 ~ 95% RH, no condensation
Working temperature
+5 ~ +45 ℃
Applications and use cases
Architectures in which C15020 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for C15020 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details