RK300-06A – Digital Noise Sensor LoRaWAN NB-IoT for Sensor Hub

Digital Noise Sensor LoRaWAN NB-IoT for Sensor Hub

Environmental Sensor Nodes

  • 30 ~ 130 dB
  • <20 mW
  • AU915
  • 31.5 Hz ~ 8 kHz
Manufacturer part number
C17014
Manufacturer
RAKwireless
Operating Temperature
-10 ℃ ~ +50 ℃ @5-80% RH
Range
30 ~ 130 dB

Digital sound level probe for monitoring noise in machines, vehicles, buildings and public spaces through a RAKwireless Sensor Hub with LoRaWAN and NB-IoT communication.

Product overview

RAKwireless RK300-06A, digital noise sensor for Sensor Hub — the RK300-06A is a digital and modular sound level meter used as a measurement probe connected to a RAKwireless Sensor Hub, LoRaWAN+NB IoT variant, AU915 band.

Measurement characteristics. measurement range of 30 to 130 dB, accuracy of ±3 dB at 23 ℃ (±5 ℃), frequency response from 31.5 Hz to 8 kHz, response time below 200 ms, capacitive microphone. Digital signal processing and digital detection provide good stability and a wide dynamic range without range switching.

Connectivity. the Sensor Hub communicates over LoRaWAN and NB-IoT. The NB-IoT module supports LTE categories CAT M1, offering higher data rates and lower latency, and CAT NB2, offering ultra-low power consumption and greater coverage, suited to battery-operated devices.

Power and environment. power consumption below 20 mW, operating temperature from -10 ℃ to +50 ℃ at 5 to 80 % relative humidity. A Sensor Hub with a probe IO and connected sensor cannot be battery powered: use only the included power supply. Shell in ABS and 304SS. External DC power supply and solar panel power source available as options.

Typical uses. noise monitoring in machines, vehicles, ships, electrical appliances, warehouses and public places, as well as worker protection and industrial hygiene where environmental noise measurement is needed.

Extending the measurement network. a splitter cable connects several sensor probes and probe IOs to a single Sensor Hub port, and an extension cable increases the distance between the Sensor Hub and the probe.

See all specifications

Highlights

  • Frequency band: AU915
  • Response time: <200 ms
  • Accuracy: ±3 dB @23 ℃ (±5 ℃)
  • Frequency response: 31.5 Hz ~ 8 kHz
  • Microphone: Capacitive microphone
  • Operating Temperature: -10 ℃ ~ +50 ℃ @5-80% RH

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -10 ℃ ~ +50 ℃ @5-80% RH — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.