Direct-connection three-phase four-wire electricity meter up to 65A (3x277/480VAC, 60 Hz), Class B / Class 1.0 active accuracy, bidirectional measurement, 7-digit LCD, and Modbus RTU.
Frequency Range0.98-1.02fn
Voltage Range0.8-1.15Un
Current Circuit<4VA at Ib
Maximum current Imax65A
Minimum Current (Imin)0.25 A
Reference current Irer=Ib=10Ir5A
Product overview
Overview. The Reallin D3001-VY (reference 271891756) is a three-phase four-wire direct-connection electricity meter that wires directly into AC circuits without requiring external current transformers.
Metrological Specifications. Rated for a nominal voltage Un of 3x277/480VAC (0.8-1.15Un range) at 60 Hz with a 5A reference current Ib and 65A maximum current Imax (0.25 A Imin, 0.004I starting current), the meter complies with Class B (DIN EN 50470-1/3) and Class 1.0 (IEC62053-21) for active energy, and Class 2.0 (IEC62053-23) for reactive energy. It supports bidirectional energy measurement (+A/-A, +R/-R) and reverse locking.
Display and Communication. Equipped with a 7-digit LCD and 1000 imp/kWh, 1000 imp/kvarh LED pulse outputs, the meter communicates via Modbus RTU at selectable 9600/19200/38400 bps (8E1/8N1/8O1) settings. Designed for a >12 years life cycle, it operates from -30℃ to +70℃ (-40℃ to +85℃ storage).
Direct-connection three-phase four-wire electricity meter up to 65A (3x277/480VAC, 60 Hz), Class B / Class 1.0 active accuracy, bidirectional measurement, 7-digit LCD, and Modbus RTU.
Frequency Range0.98-1.02fn
Voltage Range0.8-1.15Un
Current Circuit<4VA at Ib
Maximum current Imax65A
Minimum Current (Imin)0.25 A
2. Datasheet extract (recorded values)
Parameter
Value
Active
Class B in compliance with DIN EN 50470-1/3; Class 1.0 in compliance with IEC62053-21
Architectures in which 271891756 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Solar production, storage and charging points on one site are often managed separately. Inverters, batteries, MPPT controllers, meters and chargers form a local energy system that shares production between users
To check
Regulatory framework for collective self-consumption in the country
Energy management system steering storage and charging
Metering accuracy for sharing between participants
Associated system blocks
ProductionStorageMeteringCharging
Need a complete solution?
Send a request for 271891756 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productReallin
271891756
Direct-connection three-phase four-wire electricity energy meter
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details