Three-phase electronic energy meter measuring active and reactive energy, with RS485 output and LCD display, for industrial and commercial three-phase networks.
Temperature rangeoperation:-40-70℃
Voltage Range70%un~140%un
Communication interfaceRS485 port,up to38400 b ps
Current circuit apparent power at Ib<1VA
Maximum current Imax80A
Minimum Current (Imin)0.25A
Product overview
Reallin three-phase meter. The Reallin Three Phase Electronic Electricity Meter is a three-phase electronic energy meter made by Reallin in Hangzhou, China. It measures active and reactive energy on a three-phase four-wire network.
Main characteristics. Rated voltage 3x230/400 V, rated frequency 50 Hz, voltage range 70% to 140% Un, reference current Ib of 5 A and maximum current Imax of 80 A, with a starting current of 0.4% Ib and a minimum current of 0.25 A. Accuracy is class B/1.0 for active energy and class 2.0 for reactive energy. The pulse constant is 1000 imp/kWh and 1000 imp/kvarh, indicated by an LED.
Interfaces and connectivity. The meter has an RS485 communication port up to 38400 bps. The dot matrix LCD display supports backlight.
Power and environment. Voltage circuit consumption is at most 1.5 W / 8 VA and current circuit apparent power at Ib is below 1 VA. The operating temperature range is -40 to 70 °C. Protection degree is IP51 in a protective enclosure, with insulation class II. Dimensions 90 x 52.5 x 62 mm, weight about 0.3 kg.
Standards. The product complies with EN 50470-3:2022, IEC 62053-21/23:2020, IEC 62052-31:2015, UL61010-1 and UL61010-2-030.
Typical uses and integration. Through its RS485 port, the meter can be connected to a supervision or remote meter reading system to monitor consumption on a three-phase network. Available on quotation from Atlas Electronics.
Three-phase electronic energy meter measuring active and reactive energy, with RS485 output and LCD display, for industrial and commercial three-phase networks.
Temperature rangeoperation:-40-70℃
Voltage Range70%un~140%un
Communication interfaceRS485 port,up to38400 b ps
Current circuit apparent power at Ib<1VA
Maximum current Imax80A
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
class B/1.0 for active; class 2.0 for reactive
Communication interface
RS485 port,up to38400 b ps
Current circuit apparent power at Ib
<1VA
Dimension(LXW XD)
90x52.5x62mm
Insulation Class
II
LCD display
Dot Matrix type,backlight supported
Maximum current Imax
80A
Minimum Current (Imin)
0.25A
port ect ion Degree
IP51 in protective enclosure
Pulsating Indicator
LED
Pulsating(meter constant)
1000 imp/kwh; 1000 imp/kvarh
Rated Frequency Fn
50HZ
Rated Voltage Un
3x230/400v
Reference current Ib
5A
Standards
EN 50470-3:2022,IEC 62053-21/23:2020,IEC 62052-31:2015,UL61010-1,UL61010-2-030
Starting Current (Ist)
0.4%Ib
Temperature range
operation:-40-70℃
voltage circuit active lap parent power atun
≤ 1.5W/8VA
Voltage Range
70%un~140%un
Weight Of Meter
About0.3kg
Applications and use cases
Architectures in which 286095792 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Energy bills give one total for the whole site. Submetering places meters and current sensors on each circuit or usage and collects their readings through a gateway, so consumption can be followed per building, floor or machine
To check
Number of circuits and phases to meter, and the current range of each
Wired Modbus bus or wireless LoRaWAN, depending on cabling access in the switchboards
Accuracy class required for internal allocation or for billing
Solar production, storage and charging points on one site are often managed separately. Inverters, batteries, MPPT controllers, meters and chargers form a local energy system that shares production between users
To check
Regulatory framework for collective self-consumption in the country
Energy management system steering storage and charging
Metering accuracy for sharing between participants
Associated system blocks
ProductionStorageMeteringCharging
Need a complete solution?
Send a request for 286095792 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productReallin
286095792
Three-phase electronic energy meter with RS485 port
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details