Renke dew point sensor with RS485 Modbus output, designed to measure water vapour content in compressed air and industrial gases, notably downstream of dryers.
Dew point temperature range-30℃~100℃
Temperature and humidity range-40℃~+80℃, 0%RH-100%RH
Current Output Load≤600Ω
Max Power ConsumptionNormally ≤0.3W, during calibration ≤2W
Accuracy — Dew Point±2℃(25℃,15%RH)
Accuracy — Relative Humidity±3%RH(60%RH,25℃)
Product overview
Overview. The Renke RS-DEW-N01-S-T is an industrial dew point sensor that determines the water vapour content from the relative humidity and temperature of the air, then calculates the dew point value. Two models exist, RS-DEW-N01-S-T and RS-DEW-N01-2-*-T; the model is indicated in the specifications.
Main characteristics. Dew point range from -60 °C to +60 °C, with 0.1 °C resolution. Accuracy of ±2 °C on dew point (25 °C, 15 %RH), ±3 %RH on relative humidity (60 %RH, 25 °C) and ±0.4 °C on temperature (25 °C). Long-term stability of ≤1 %RH/y for relative humidity and ≤0.1 °C/y for temperature. Response time of ≤8 s for relative humidity and ≤25 s for temperature at 1 m/s wind speed. Refresh time of 2 s.
Interfaces and connectivity. RS485 output with Modbus protocol, and 4~20 mA output for dew point only. Current output load ≤600 Ω.
Power and environment. DC 10-30 V power supply. Maximum power consumption normally ≤0.3 W, and ≤2 W during calibration. Operating environment from -40 °C to +80 °C, 0 to 95 %RH non-condensing. Protection class IP65. G1/2″ threaded mounting.
Construction. The sensor uses polymer film capacitive sensing technology, with an industrial grade microprocessor chip and a high precision temperature sensor. The probe is fitted with a 316 stainless steel sintered filter and integrates a calibration function. The housing is 304 stainless steel with a fully sealed cable outlet.
Typical uses. Monitoring the dew point of compressed air and gases, notably downstream of refrigerated and desiccant dryers and in air storage tanks, where an alarm can be triggered when a preset value is reached. It can also serve outdoor measurements, for example in meteorology and agriculture.
Integration. Connection to a PLC or supervision system is made through the RS485 link using the Modbus protocol.
Renke dew point sensor with RS485 Modbus output, designed to measure water vapour content in compressed air and industrial gases, notably downstream of dryers.
Dew point temperature range-30℃~100℃
Temperature and humidity range-40℃~+80℃, 0%RH-100%RH
Current Output Load≤600Ω
Max Power ConsumptionNormally ≤0.3W, during calibration ≤2W
Accuracy — Dew Point±2℃(25℃,15%RH)
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy — Dew Point
±2℃(25℃,15%RH)
Accuracy — Relative Humidity
±3%RH(60%RH,25℃)
Accuracy — Temperature
±0.4℃ (25℃)
Current Output Load
≤600Ω
Dew point resolution
0.1℃
Dew point temperature range
-30℃~100℃
Installation
G1/2″ Threaded Mounting
Long-term stability — Relative humidity
≤1%RH/y
Long-term stability — Temperature
≤0.1℃/y
Max Power Consumption
Normally ≤0.3W, during calibration ≤2W
Model
RS-DEW-N01-2-*-T/RS-DEW-N01-S-T
Operating Environment
-40℃~+80℃, 0%RH~95%RH (Non Condensation)
Output signal
RS485(ModBus Protocol)
Output Signal — RS485(ModBus Protocol)
4~20mA(dew point only)
Power supply
DC 10-30V
Protection Class
IP65
Range — Dew Point
-60℃~+60℃
Range — Temperature
-40℃~+80℃
Refresh Time
2s
Resolution — Dew Point
0.1℃
Resolution — Temperature
0.1℃
Response time — Relative humidity
≤8s(1m/s Wind Speed)
Response time — Temperature
≤25s(1m/s Wind Speed)
Temperature and humidity range
-40℃~+80℃, 0%RH-100%RH
Temperature humidity resolution
0.1℃, 0.1%RH
Applications and use cases
Architectures in which DEW-POINT-SENSOR can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
A fridge that drifts at night can ruin a whole stock. Temperature loggers in cold rooms and trucks report through a gateway or a tracker and raise an alert when a threshold is crossed
To check
Temperature range and accuracy required by the product
Record keeping required by the applicable regulations
A building’s energy, comfort and occupancy data sit in separate systems. Sensors, meters and gateways feed one model of the building, room by room, to compare scenarios and steer the installations
To check
Data model and building plans available
Software platform hosting the twin
Sensor density needed for a useful model
Associated system blocks
SensorsMetersGateways
Need a complete solution?
Send a request for DEW-POINT-SENSOR and the other parts of your project.
Answers to the questions that the recorded characteristics of DEW-POINT-SENSOR can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Output signal": RS485(ModBus Protocol).
2Does it support Modbus?
Yes — recorded under "Output signal": RS485(ModBus Protocol).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productRenke
DEW-POINT-SENSOR
Industrial dew point sensor with RS485 Modbus output
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details