RS-BYH-M-T – Multi-sensor RS485 solar radiation shield for weather stations

Multi-sensor RS485 solar radiation shield for weather stations

Temperature Sensor Modules

  • -40℃-+75℃
  • 0.8W
  • ±0.15kPa@25℃101kPa
  • ±(50ppm+3%F·S) (25℃)
Manufacturer part number
SOLAR-RADIATION-SHIELD
Manufacturer
Renke
Operating Temperature
-40℃-+75℃
Accuracy — CO2
±(50ppm+3%F·S) (25℃)

Renke RS-BYH-M-T solar radiation shield protecting weather sensors from solar radiation and precipitation. It accommodates temperature, humidity, pressure, CO2, PM2.5, PM10, noise and light sensors.

Product overview

Renke RS-BYH-M-T. solar radiation shield designed to protect weather sensors from direct sunlight and precipitation. It keeps sufficient airflow around the sensors to maintain accurate readings.

Main characteristics. Shield available with 4, 6, 8 or 12 plates, other plate configurations can be customised. Made of special engineering plastics resistant to radiation with stainless steel screws. Operating temperature from -40 ℃ to +75 ℃. IP68 protection rating.

Measurement capabilities. The shield can house several sensors: temperature from -40 ℃ to +120 ℃ with an accuracy of ±0.5 ℃ at 25 ℃, humidity from 0 %RH to 99 %RH with an accuracy of ±3 %RH at 60 %RH and 25 ℃, atmospheric pressure from 0 to 120 kPa with an accuracy of ±0.15 kPa at 25 ℃, CO2 from 0 to 5000 ppm with an accuracy of ±(50 ppm + 3 %F·S) at 25 ℃, PM10 and PM2.5 from 0 to 1000 µg/m³, illumination from 0 to 200000 Lux with an accuracy of ±7 % at 25 ℃, and noise from 30 dB to 130 dB.

Long-term stability. Maximum yearly drift of 0.1 ℃ for temperature, 1 %/y for humidity and CO2, -0.1 kPa/y for atmospheric pressure, 5 %/y for illumination and 3 dB/y for noise.

Power and output. DC power supply from 10 to 30 VDC, maximum power consumption of 0.8 W with RS485 output.

Typical use. Outdoor installation on a weather station, the RS485 output allowing connection to a data acquisition system or a PLC.

Integration. The shield is installed outdoors and its ventilation openings provide natural airflow around the sensors.

See all specifications

Highlights

  • Accuracy — Atmospheric pressure: ±0.15kPa@25℃101kPa
  • Accuracy — CO2: ±(50ppm+3%F·S) (25℃)
  • Accuracy — Humidity: ±3%RH(60%RH,25℃)
  • Accuracy — Illumination: ±7%(25℃)
  • Accuracy — Noise: ±0.5dB(at reference pitch, 94dB@1kHz)
  • Accuracy — PM2.5: ±3%FS(@0~100μg/m3, 25℃, 50%RH)

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Thermal: rated operating range -40℃-+75℃ — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Request a quote