101990862
Industrial MODBUS-RTU RS485 ammonia sensor IP65

- Operating Current
- 6mA ( Max , 5V DC );3.2mA(typ.12V DC)
- Parameter — Min — Typical value — Max
- Unit
- Measurement — Measurement accuracy
- Resolution
- Ambient Pressure
- Atmospheric pressure ±10%.
Industrial MODBUS-RTU RS485 ammonia sensor IP65
Seeed Studio S-NH3-01 industrial ammonia sensor with MODBUS-RTU RS485 output, measuring 0 to 100 ppm with IP65 protection for outdoor use.
Overview. The Seeed Studio S-NH3-01 industrial ammonia sensor uses solid polymer electrochemical detection, with MODBUS-RTU RS485 output and IP65 protection. It measures ammonia from 0 to 100 ppm with 0.1 ppm resolution and a typical accuracy of ±5% full scale, maximum ±10%.
Additional measurements. The sensor also measures temperature from -40 to 50 °C with 0.1 °C resolution and ±0.5 °C accuracy, and relative humidity from 10 to 95 %RH with 0.1 %RH resolution and ±5% accuracy.
Connectivity and power. Communication is over MODBUS-RTU RS485. The sensor is powered at 4.5 to 5.5 V DC, 5 V recommended, with a maximum operating current of 6 mA at 5 V DC. It is fitted with a waterproof aviation connector and a 2 meter cable.
Performance and response. In RS-485 mode the response time is 30 seconds, the warm-up time 5 minutes and the poll rate 1 second. Recalibration is recommended after approximately six months of use.
Operating environment. The sensor operates from -40 °C to 50 °C at 15 to 95% RH non-condensing, with best operating temperature between 20 and 35 °C. It should be protected from long-term direct sunlight and rain.
Typical uses. Ammonia monitoring in farming, industrial areas and meteorological monitoring, integrated into a PLC or gateway supervision system over MODBUS RS485.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for 101990862, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| IP rating | IP65 (The equipment should be protected from direct sunlight and rain over long periods of time). |
| Supply voltage | 4.5 ~5.5V DC (recommended 5V power supply) |
| Ambient Pressure | Atmospheric pressure ±10%. |
| Ammonia — 0~100 ppm — typ. ±5%F.S, max ±10%F.S | 0.1 ppm |
| Cable Length | 2 meters |
| Humidity — 10~95 %RH — ± 5% | 0.1 %RH |
| Measurement — Measurement accuracy | Resolution |
| Operating Current | 6mA ( Max , 5V DC );3.2mA(typ.12V DC) |
| Operating Humidity | 15 to 95% RH (non-condensation) (best operating humidity 50%RH). |
| Operating Temperature | -40°C to 50°C (best operating temperature 20 to 35 °C). |
| Parameter — Min — Typical value — Max | Unit |
| Product Model | S-NH3-01 |
| RS-485 mode — Poll Rate — — — 1 — — | seconds |
| RS-485 mode — Response time — — — 30 — — | seconds |
| RS-485 mode — Warm-up Time — — — 5 — — | minutes |
| Supported protocol | MODBUS-RTU RS485 |
| Temperature — -40~50 °C — ± 0.5 °C | 0.1 °C |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for 101990862. For a missing document or a specific revision, our experts send it to you.
Seeed Studio S-NH3-01 industrial ammonia sensor with MODBUS-RTU RS485 output, measuring 0 to 100 ppm with IP65 protection for outdoor use.
| Parameter | Value |
|---|---|
| IP rating | IP65 (The equipment should be protected from direct sunlight and rain over long periods of time). |
| Supply voltage | 4.5 ~5.5V DC (recommended 5V power supply) |
| Ambient Pressure | Atmospheric pressure ±10%. |
| Ammonia — 0~100 ppm — typ. ±5%F.S, max ±10%F.S | 0.1 ppm |
| Cable Length | 2 meters |
| Humidity — 10~95 %RH — ± 5% | 0.1 %RH |
| Measurement — Measurement accuracy | Resolution |
| Operating Current | 6mA ( Max , 5V DC );3.2mA(typ.12V DC) |
| Operating Humidity | 15 to 95% RH (non-condensation) (best operating humidity 50%RH). |
| Operating Temperature | -40°C to 50°C (best operating temperature 20 to 35 °C). |
| Parameter — Min — Typical value — Max | Unit |
| Product Model | S-NH3-01 |
| RS-485 mode — Poll Rate — — — 1 — — | seconds |
| RS-485 mode — Response time — — — 30 — — | seconds |
| RS-485 mode — Warm-up Time — — — 5 — — | minutes |
| Supported protocol | MODBUS-RTU RS485 |
| Temperature — -40~50 °C — ± 0.5 °C | 0.1 °C |
Points to check before using 101990862 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
| Supply voltage | 4.5 ~5.5V DC (recommended 5V power supply) |
| Operating Current | 6mA ( Max , 5V DC );3.2mA(typ.12V DC) |
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Answers to the questions that the recorded characteristics of 101990862 can answer. A question is not asked when nothing is recorded to answer it.
Yes — recorded under "RS-485 mode — Poll Rate — — — 1 — —": seconds.
Yes — recorded under "Supported protocol": MODBUS-RTU RS485.
4.5 ~5.5V DC (recommended 5V power supply) (source: Supply voltage).
-40°C to 50°C (best operating temperature 20 to 35 °C). (source: Operating Temperature).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Industrial MODBUS-RTU RS485 ammonia sensor IP65

SS316 LPG Mass Flow Meter Ammonia Gas 1.6Mpa 10A 220V Thermal Mass Air Flow Meter

Ammonia Nitrogen Sensor

Ammonia Sensor

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | 101990862 |
| Manufacturer | Seeed Studio |
Ammonia Sensors
Ammonia NH3 Gas Detector with 4-20 mA Output · Ref. : FX-NH3
Price on request
Ammonia Sensors
Low-Power MEMS Ammonia Gas Sensor, 1-300 ppm · Ref. : SEN0567
Price on request
Ammonia Sensors
MICS6814 3-in-1 gas sensor breakout (CO, NO2, NH3), I2C · Ref. : PIM569
Price on request
Ammonia Sensors
Industrial online NH3-N ammonia nitrogen analyzer · Ref. : NHNG-3010
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details