8-in-1 LoRaWAN weather station from Seeed Studio measuring air temperature, humidity, wind speed and direction, rainfall intensity, light intensity, UV index and barometric pressure for gardens, agriculture and urban environmental monitoring.
Operating Temperature Range-10°C to 50°C (14°F to 122°F)
RangeRange
Frequency Plan — Common NameSub-band
AccuracyAccuracy
Air HumidityGeneral Parameters
AS923AS923_1, AS923_2, AS923_3, AS923_4
Product overview
Overview. The Seeed Studio S2120 8-in-1 LoRaWAN weather sensor is an outdoor environmental sensor node that combines eight measurements in one device: air temperature, humidity, wind speed and direction, rainfall intensity, light intensity, UV index and barometric pressure. Data are uploaded over a LoRaWAN network.
Main characteristics. The S2120 has an operating temperature range of -10°C to 50°C (14°F to 122°F) and an IPX6 rating for the external battery box. It is not rechargeable and runs on AA 1.5V batteries (not included), three in the built-in battery box or six in the external box, whose cable measures 2m.
Interfaces and connectivity. The device has built-in Bluetooth for OTA configuration, completed in one minute with the SenseCAP Mate App, and supports remote management of real-time and historical data via the SenseCAP Portal. It is compatible with LoRaWAN networks including Helium, The Things Network, Loriot and Chirpstack, and the AS923, AU915-928 and US902-928 frequency plans are supported.
Power and environment. The unit is powered by AA 1.5V batteries and requires maintenance every six months or upon a remote low-battery alert. Capacity drops to 40–50% at -10°C, with a risk of device reset during transmission peaks, and there is a risk of electrolyte leakage above 45°C. Allow the unit to reach room temperature before opening the battery compartment to avoid condensation.
Typical uses. Climate monitoring in gardens and outdoor spaces, smart agriculture to give farmers timely climate data, and urban environmental monitoring. The S2120 suits deployments where ambient temperatures stay consistently above -10°C.
Integration. Accessories such as poles and a mounting stand allow quick outdoor installation. The manufacturer recommends the SenseCAP M2 multi-platform gateway for a standard LoRaWAN network.
When bringing stations from sub-zero environments into heated spaces for maintenance, allow the entire unit to reach room temperature and confirm zero condensation on internal surfaces before opening the battery compartment. Moisture on terminals causes corrosion and potential short circuits.
Resolution
Resolution
Selection Guide
Urban and agricultural deployments with ambient temperatures consistently above -10°C
Specification
AA size, 1.5V power supply ( batteries not included )
Temperature Performance
40–50% capacity at -10°C (significantly increased internal resistance that may cause device reset during data transmission peaks); H ave risk of electrolyte leakage and accelerated self-discharge above 45°C
US902-928 — US915
Sub-band from 1 to 8
Wind Direction
Device Weight
Wind Speed
LoRa Sensitivity
No specification matches.
Last verification : 2026-11-01
Technical documentation
Official documents and the technical data recorded for 101990961. For a missing document or a specific revision, our experts send it to you.
8-in-1 LoRaWAN weather station from Seeed Studio measuring air temperature, humidity, wind speed and direction, rainfall intensity, light intensity, UV index and barometric pressure for gardens, agriculture and urban environmental monitoring.
Operating Temperature Range-10°C to 50°C (14°F to 122°F)
RangeRange
Frequency Plan — Common NameSub-band
AccuracyAccuracy
Air HumidityGeneral Parameters
2. Datasheet extract (recorded values)
Parameter
Value
Accuracy
Accuracy
Air Humidity
General Parameters
AS923
AS923_1, AS923_2, AS923_3, AS923_4
AU915-928 — AU915
Sub-band from 1 to 8
Barometric pressure
Built-in Bluetooth
External Battery Box
Support 6 * AA 1.5V batteries(batteries not included); Cable: 2m; IP Rating: IPX6
Frequency Plan — Common Name
Sub-band
Light Intensity
UV Index
Maintenance G u i d e
Replace every 6 months or upon remote low-battery alert
When bringing stations from sub-zero environments into heated spaces for maintenance, allow the entire unit to reach room temperature and confirm zero condensation on internal surfaces before opening the battery compartment. Moisture on terminals causes corrosion and potential short circuits.
Resolution
Resolution
Selection Guide
Urban and agricultural deployments with ambient temperatures consistently above -10°C
Specification
AA size, 1.5V power supply ( batteries not included )
Temperature Performance
40–50% capacity at -10°C (significantly increased internal resistance that may cause device reset during data transmission peaks); H ave risk of electrolyte leakage and accelerated self-discharge above 45°C
US902-928 — US915
Sub-band from 1 to 8
Wind Direction
Device Weight
Wind Speed
LoRa Sensitivity
Integration
Points to check before using 101990961 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -10°C to 50°C (14°F to 122°F) — check it against the installation environment.
Power and communication
External Battery Box
Support 6 * AA 1.5V batteries(batteries not included); Cable: 2m; IP Rating: IPX6
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -10°C to 50°C (14°F to 122°F) — check it against the installation environment.
Applications and use cases
Architectures in which 101990961 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for 101990961 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSeeed Studio
101990961
8-in-1 LoRaWAN Weather Station with Multiple Sensors
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details