IP66 10-in-1 weather and environmental sensor measuring air temperature, humidity, pressure, light, rainfall, ultrasonic wind, PM2.5, PM10, and CO2 via RS485 (MODBUS-RTU) and SDI-12.
Operating temp. & humidity-40°C to +85°C; 0-100%RH
Range- 40 °C ~ + 85 °C
Wind direction range0-360°
InterfaceM12 connector
Power consumption0.4W; heating 21W
Accuracy± 0.1℃
Product overview
Overview. The Seeed Studio SenseCAP S1000 V2 (reference 101991024) is a 10-in-1 compact weather and air quality sensor housed in an IP66 enclosure measuring 140 x 140 x 320mm (1470g). It monitors 10 parameters: air temperature, relative humidity, barometric pressure, light intensity, rainfall, ultrasonic wind speed and direction, PM2.5, PM10, and CO2.
Accuracy and Measurement Ranges. Temperature is measured from -40°C to +85°C (±0.1°C, with an effective CO2 range of 0~50°C), humidity from 0-100%RH (±1.5%RH), pressure from 300-1250hPa (±50Pa), and light from 0-200,000Lux (±5%). The ultrasonic wind sensor without moving parts measures speed from 0-60m/s standard (0-75m/s extended, up to 80m/s withstand) and direction across 0-360° (±3.0°).
Connectivity and Power. Featuring RS485 (MODBUS-RTU) and SDI-12 output on an M12 8-pin connector (3m cable and USB Type-C cable included), the unit runs on 12V~24V (0.4W) with an independent 24V heating supply (21W).
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for 101991024, with where it comes from. Use the filters to find one quickly.
All specifications (31)
Characteristic
Value
IP rating
IP66
Accuracy
± 0.1℃
Air Humidity
0-100%RH; ±1.5%RH; resolution 0.01%RH
Air Temperature
-40°C to +85°C; ±0.1°C; resolution 0.01°C
Applications
Agriculture, smart cities, outdoor monitoring
Barometric pressure
300-1250hPa; ±50Pa; resolution 10Pa
Cable Length
3m
Device weight
2kg
Dimension
140 x 140 x 320mm
Interface
M12 connector
IP Rating / Weight
IP66; 1470g
Light Intensity
0-200,000Lux; ±5%; resolution 5Lux
Operating temp. & humidity
-40°C to +85°C; 0-100%RH
Operating Temperature & Humidity
-40 °C ~ + 85 °C (The effective range of CO2 is 0~50°C),; 0 ~ 100%RH
Parameters Measured
air temperature, relative humidity, barometric pressure, light intensity, rainfall, wind speed, wind direction, PM2.5, PM10 and CO2
Part list
SenseCAP ONE All-in-one Compact Weather Sensor x1; M12 8-pin communication cable (default length 3-meter hook-up wire and there is a waterproof aviation connector type to choose from when working with SenseCAP SensorHub datalogger. If the aviation connector is not needed, cut it off by yourself) x1; USB Type-C cable, for configuring devices x1; Screw x6; Flat washer (to open the configuration port) x1
Power consumption
0.4W; heating 21W
Power supply
12V~24V; 24V(Heating power supply)
Product Model
S200
Protocol
RS485 (MODBUS-RTU) / SDI-12
Range
- 40 °C ~ + 85 °C
Resolution
0.01 ℃
Wind Direction
0-360°; ±3.0°; resolution 0.1°
wind direction — Accuracy
±3.0°
Wind direction range
0-360°
wind direction — Resolution
0.1°
Wind Sensor Design
Ultrasonic, no moving parts
Wind Speed
0-60m/s std.; ±0.3m/s (≤10m/s); resolution 0.1m/s
Wind speed — Accuracy
±0.3m/s (≤10m/s); ±3% (10-50m/s); ±5% (>50m/s)
Wind speed range
0-60m/s standard; 0-75m/s extended; up to 80m/s withstand
Wind speed — Resolution
0.1m/s
No specification matches.
Last verification : 2026-11-01
Technical documentation
Official documents and the technical data recorded for 101991024. For a missing document or a specific revision, our experts send it to you.
IP66 10-in-1 weather and environmental sensor measuring air temperature, humidity, pressure, light, rainfall, ultrasonic wind, PM2.5, PM10, and CO2 via RS485 (MODBUS-RTU) and SDI-12.
Operating temp. & humidity-40°C to +85°C; 0-100%RH
Range- 40 °C ~ + 85 °C
Wind direction range0-360°
InterfaceM12 connector
Power consumption0.4W; heating 21W
2. Datasheet extract (recorded values)
Parameter
Value
IP rating
IP66
Accuracy
± 0.1℃
Air Humidity
0-100%RH; ±1.5%RH; resolution 0.01%RH
Air Temperature
-40°C to +85°C; ±0.1°C; resolution 0.01°C
Applications
Agriculture, smart cities, outdoor monitoring
Barometric pressure
300-1250hPa; ±50Pa; resolution 10Pa
Cable Length
3m
Device weight
2kg
Dimension
140 x 140 x 320mm
Interface
M12 connector
IP Rating / Weight
IP66; 1470g
Light Intensity
0-200,000Lux; ±5%; resolution 5Lux
Operating temp. & humidity
-40°C to +85°C; 0-100%RH
Operating Temperature & Humidity
-40 °C ~ + 85 °C (The effective range of CO2 is 0~50°C),; 0 ~ 100%RH
Parameters Measured
air temperature, relative humidity, barometric pressure, light intensity, rainfall, wind speed, wind direction, PM2.5, PM10 and CO2
Part list
SenseCAP ONE All-in-one Compact Weather Sensor x1; M12 8-pin communication cable (default length 3-meter hook-up wire and there is a waterproof aviation connector type to choose from when working with SenseCAP SensorHub datalogger. If the aviation connector is not needed, cut it off by yourself) x1; USB Type-C cable, for configuring devices x1; Screw x6; Flat washer (to open the configuration port) x1
Power consumption
0.4W; heating 21W
Power supply
12V~24V; 24V(Heating power supply)
Product Model
S200
Protocol
RS485 (MODBUS-RTU) / SDI-12
Range
- 40 °C ~ + 85 °C
Resolution
0.01 ℃
Wind Direction
0-360°; ±3.0°; resolution 0.1°
wind direction — Accuracy
±3.0°
Wind direction range
0-360°
wind direction — Resolution
0.1°
Wind Sensor Design
Ultrasonic, no moving parts
Wind Speed
0-60m/s std.; ±0.3m/s (≤10m/s); resolution 0.1m/s
Wind speed — Accuracy
±0.3m/s (≤10m/s); ±3% (10-50m/s); ±5% (>50m/s)
Wind speed range
0-60m/s standard; 0-75m/s extended; up to 80m/s withstand
Wind speed — Resolution
0.1m/s
Integration
Points to check before using 101991024 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40°C to +85°C; 0-100%RH — check it against the installation environment.
Power and communication
Power consumption
0.4W; heating 21W
Power supply
12V~24V; 24V(Heating power supply)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40°C to +85°C; 0-100%RH — check it against the installation environment.
Applications and use cases
Architectures in which 101991024 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for 101991024 and the other parts of your project.
Answers to the questions that the recorded characteristics of 101991024 can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Protocol": RS485 (MODBUS-RTU) / SDI-12.
2Does it support Modbus?
Yes — recorded under "Protocol": RS485 (MODBUS-RTU) / SDI-12.
3Does it have a USB interface?
Yes — recorded under "Part list": SenseCAP ONE All-in-one Compact Weather Sensor x1; M12 8-pin communication cable (default length 3-meter hook-up wire and there is a waterproof aviation connector type to choose from when working with SenseCAP SensorHub datalogger. If the aviation connector is not needed, cut it off by yourself) x1; USB Type-C cable, for configuring devices x1; Screw x6; Flat washer (to open the configuration port) x1.
4What is the operating temperature range?
-40°C to +85°C; 0-100%RH (source: Operating temp. & humidity).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSeeed Studio
101991024
10-in-1 compact weather sensor with PM2.5, PM10, and CO2
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details