NDIR 3-in-1 digital sensor measuring CO2, air temperature and relative humidity, with Modbus RS485 and SDI-12 outputs, for indoor and outdoor air monitoring.
Seeed Studio S-CO2-03A / S-CO2-03B is a CO2, temperature and humidity sensor node with digital RS485 Modbus-RTU, Modbus-ASCII and SDI-12 (v1.4) outputs. It is an NDIR (non-dispersive infrared) CO2 sensor combining measurement of CO2, air temperature and relative humidity.
Main characteristics. CO2 measurement from 0 to 10,000 ppm with an accuracy of ±(50 ppm + 3 % of the measured value) and a resolution of 1 ppm. Air temperature is measured from -40 to 85 °C with an accuracy of ±0.2 °C, and relative humidity from 0 to 100 %RH with an accuracy of ±1.8 %RH. The sensor comes with a 2-metre cable.
Interfaces and connectivity. RS485 outputs (Modbus-RTU and Modbus-ASCII) and SDI-12 (v1.4), allowing connection to a PLC, a data logger or a compatible gateway. The waterproof aviation connector simplifies wiring to a logger without screw terminals.
Power and environment. Supply voltage from 5 to 24 V. Protection rating IP65; for outdoor installation, shading measures are required and the equipment must not be exposed to direct sunlight or rainwater for a long time. Operating temperature from 0 to +50 °C, limited by the CO2 sensor, and working humidity from 0 to 95 %RH, without condensation.
Typical uses. Greenhouses, building ventilation systems, public places, laboratories and warehouses, as well as smart agriculture, where CO2 level measurement is needed. The sensor is factory-calibrated and can be recalibrated by pressing keys or using commands.
Integration. For remote transmission, the sensor can be connected to a SenseCAP data logger, compatible with LoRaWAN and 4G networks depending on the chosen version.
NDIR 3-in-1 digital sensor measuring CO2, air temperature and relative humidity, with Modbus RS485 and SDI-12 outputs, for indoor and outdoor air monitoring.
Supply voltage5 ~ 24 V
Range & AccuracyResolution
Air Humidity — 0~100%RH — ±1.8%RH0.01%RH
Air Temperature — -40~85°C — ±0.2℃0.01°C
Cable Length2 meters
2. Datasheet extract (recorded values)
Parameter
Value
IP rating
IP65 (shading measures are required for outdoor installation, and the equipment cannot be exposed to direct sunlight and rainwater for a long time)
Points to check before using 101991029 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with 5 ~ 24 V.
2Thermalrated operating range 0°C ~ +50°C (Due to CO2 sensor limitations) — check it against the installation environment.
Power and communication
Supply voltage
5 ~ 24 V
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with 5 ~ 24 V.
Thermal : rated operating range 0°C ~ +50°C (Due to CO2 sensor limitations) — check it against the installation environment.
Applications and use cases
Architectures in which 101991029 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for 101991029 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSeeed Studio
101991029
CO2, Temperature and Humidity Sensor RS485 and SDI-12 IP65
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
IP65 (shading measures are required for outdoor installation, and the equipment cannot be exposed to direct sunlight and rainwater for a long time)IP rating
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details