S-CO2-03A / S-CO2-03B – CO2, Temperature and Humidity Sensor RS485 and SDI-12 IP65

CO2, Temperature and Humidity Sensor RS485 and SDI-12 IP65

Environmental Sensor Nodes

  • 5 ~ 24 V
  • Resolution
  • 0.01%RH
  • 0.01°C
Manufacturer part number
101991029
Manufacturer
Seeed Studio
Supply voltage
5 ~ 24 V
Range & Accuracy
Resolution

NDIR 3-in-1 digital sensor measuring CO2, air temperature and relative humidity, with Modbus RS485 and SDI-12 outputs, for indoor and outdoor air monitoring.

Product overview

Seeed Studio S-CO2-03A / S-CO2-03B is a CO2, temperature and humidity sensor node with digital RS485 Modbus-RTU, Modbus-ASCII and SDI-12 (v1.4) outputs. It is an NDIR (non-dispersive infrared) CO2 sensor combining measurement of CO2, air temperature and relative humidity.

Main characteristics. CO2 measurement from 0 to 10,000 ppm with an accuracy of ±(50 ppm + 3 % of the measured value) and a resolution of 1 ppm. Air temperature is measured from -40 to 85 °C with an accuracy of ±0.2 °C, and relative humidity from 0 to 100 %RH with an accuracy of ±1.8 %RH. The sensor comes with a 2-metre cable.

Interfaces and connectivity. RS485 outputs (Modbus-RTU and Modbus-ASCII) and SDI-12 (v1.4), allowing connection to a PLC, a data logger or a compatible gateway. The waterproof aviation connector simplifies wiring to a logger without screw terminals.

Power and environment. Supply voltage from 5 to 24 V. Protection rating IP65; for outdoor installation, shading measures are required and the equipment must not be exposed to direct sunlight or rainwater for a long time. Operating temperature from 0 to +50 °C, limited by the CO2 sensor, and working humidity from 0 to 95 %RH, without condensation.

Typical uses. Greenhouses, building ventilation systems, public places, laboratories and warehouses, as well as smart agriculture, where CO2 level measurement is needed. The sensor is factory-calibrated and can be recalibrated by pressing keys or using commands.

Integration. For remote transmission, the sensor can be connected to a SenseCAP data logger, compatible with LoRaWAN and 4G networks depending on the chosen version.

See all specifications

Highlights

  • Supply voltage: 5 ~ 24 V
  • Air Humidity — 0~100%RH — ±1.8%RH: 0.01%RH
  • Air Temperature — -40~85°C — ±0.2℃: 0.01°C
  • Cable Length: 2 meters
  • Carbon Dioxide — 0 ~ 10000ppm — ±(50ppm+3%*MV): 1ppm
  • Operating Temperature: 0°C ~ +50°C (Due to CO2 sensor limitations)

Typical applications

Derived from the part category, not a compatibility statement.

Good to know before integrating

  • Power: plan for a supply compatible with 5 ~ 24 V.
  • Thermal: rated operating range 0°C ~ +50°C (Due to CO2 sensor limitations) — check it against the installation environment.

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.