Compact outdoor weather station measuring air temperature, humidity, pressure, light, wind and precipitation in a single sensor, for agricultural and urban monitoring.
Operating temp. & humidity-40°C to +85°C; 0-100%RH
Operating Temperature & Humidity-40 °C ~ + 85 °C, 0 ~ 100%RH
Range- 40 °C ~ + 85 °C
Wind direction range0-360°
InterfaceM12 connector
Power consumption0.4W; heating 21W
Product overview
Seeed Studio S700-A, 7-in-1 compact weather station — the S700-A combines seven measurements in one outdoor sensor: air temperature and humidity, barometric pressure, light intensity, wind speed and direction, and precipitation intensity. It suits installations that need local climate readings without mounting several separate devices on a pole.
Radar rainfall measurement. precipitation intensity is derived from electromagnetic wave scattering analysis, a method stated to offer a wider measuring range and higher accuracy, suited to large-area precipitation monitoring.
Wind without moving parts. wind speed and direction are measured by ultrasonic sensors. Speed ranges from 0 to 60 m/s as standard, extendable to 0-75 m/s, with survival up to 80 m/s; accuracy is ±0.3 m/s up to 10 m/s, and direction covers 0 to 360° with ±3.0° accuracy.
Temperature, humidity and pressure. air temperature is measured from -40 °C to +85 °C with ±0.1 °C accuracy and 0.01 °C resolution; relative humidity from 0 to 100 %RH at ±1.5 %RH; barometric pressure from 300 to 1250 hPa at ±50 Pa.
IP66 enclosure and heating. the IP66 housing is waterproof and dustproof. A thermostatically controlled heater, powered from an independent 24 V supply, is provided for extremely cold environments; it draws 21 W against 0.4 W in normal operation.
Power and communication. the unit runs on 12 to 24 V and outputs RS485 (MODBUS-RTU) or SDI-12 through an M12 connector, with a 3 m cable for pole mounting.
Compact outdoor weather station measuring air temperature, humidity, pressure, light, wind and precipitation in a single sensor, for agricultural and urban monitoring.
Operating temp. & humidity-40°C to +85°C; 0-100%RH
Operating Temperature & Humidity-40 °C ~ + 85 °C, 0 ~ 100%RH
Range- 40 °C ~ + 85 °C
Wind direction range0-360°
InterfaceM12 connector
2. Datasheet extract (recorded values)
Parameter
Value
IP rating
IP66
Accuracy
± 0.1℃
Air Humidity
0-100%RH; ±1.5%RH; resolution 0.01%RH
Air Temperature
-40°C to +85°C; ±0.1°C; resolution 0.01°C
Applications
Agriculture, smart cities, outdoor monitoring
Barometric pressure
300-1250hPa; ±50Pa; resolution 10Pa
Cable Length
3m
Device weight
2kg
Dimension
140 x 140 x 320mm
Interface
M12 connector
IP Rating / Weight
IP66; 1470g
Light Intensity
0-200,000Lux; ±5%; resolution 5Lux
Operating temp. & humidity
-40°C to +85°C; 0-100%RH
Operating Temperature & Humidity
-40 °C ~ + 85 °C, 0 ~ 100%RH
Parameters Measured
air temperature, relative humidity, barometric pressure, wind speed, wind direction,rainfall intensity ( r a d a r ) and light intensity
Power consumption
0.4W; heating 21W
Power supply
12V~24V; 24V(Heating power supply)
Product Model
S200
Protocol
RS485 (MODBUS-RTU) / SDI-12
Range
- 40 °C ~ + 85 °C
Resolution
0.01 ℃
Wind Direction
0-360°; ±3.0°; resolution 0.1°
wind direction — Accuracy
±3.0°
Wind direction range
0-360°
wind direction — Resolution
0.1°
Wind Sensor Design
Ultrasonic, no moving parts
Wind Speed
0-60m/s std.; ±0.3m/s (≤10m/s); resolution 0.1m/s
Wind speed — Accuracy
±0.3m/s (≤10m/s); ±3% (10-50m/s); ±5% (>50m/s)
Wind speed range
0-60m/s standard; 0-75m/s extended; up to 80m/s withstand
Wind speed — Resolution
0.1m/s
Integration
Points to check before using 101991050 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40°C to +85°C; 0-100%RH — check it against the installation environment.
2Thermalrated operating range -40 °C ~ + 85 °C, 0 ~ 100%RH — check it against the installation environment.
Power and communication
Power consumption
0.4W; heating 21W
Power supply
12V~24V; 24V(Heating power supply)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40°C to +85°C; 0-100%RH — check it against the installation environment.
Thermal : rated operating range -40 °C ~ + 85 °C, 0 ~ 100%RH — check it against the installation environment.
Applications and use cases
Architectures in which 101991050 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
Power of the field devices (battery, solar)
Gateway coverage over the farm
Associated system blocks
Weather stationSoil and field sensorsGateway
Need a complete solution?
Send a request for 101991050 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSeeed Studio
101991050
7-in-1 Compact Weather Station with Radar Rain Sensor
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details