Compact weather sensor measuring air temperature, relative humidity, barometric pressure, wind speed and wind direction. Designed for outdoor use, with RS485 MODBUS-RTU and SDI-12 output.
Operating temp. & humidity-40°C to +85°C; 0-100%RH
Operating Temperature & Humidity-40 °C ~ + 85 °C, 0 ~ 100%RH
Range- 40 °C ~ + 85 °C
Wind direction range0-360°
InterfaceM12 connector
Power consumption0.4W; heating 21W
Product overview
Overview. The Seeed Studio SenseCAP S500 V2 is a compact 5-in-1 weather station that measures air temperature, relative humidity, barometric pressure, wind speed and wind direction in a single sensor. The wind sensors are ultrasonic, with no moving parts.
Measurement characteristics. Air temperature from -40 °C to +85 °C, accuracy ±0.1 °C, resolution 0.01 °C. Relative humidity from 0 to 100 %RH, accuracy ±1.5 %RH. Barometric pressure from 300 to 1250 hPa, accuracy ±50 Pa. Wind speed from 0 to 60 m/s standard, accuracy ±0.3 m/s up to 10 m/s, extended range 0-75 m/s, withstands up to 80 m/s. Wind direction from 0 to 360°, accuracy ±3.0°.
Interfaces and connectivity. RS485 (MODBUS-RTU) or SDI-12 output, M12 8-pin connector, with a 3 m cable supplied. A USB Type-C port is used for device configuration.
Power and environment. Power supply 12V to 24V, with a separate 24V heating power supply for use in extremely cold environments. Power consumption 0.4 W, 21 W with heating. IP66 rating, weight 1470 g, dimensions 140 x 140 x 320 mm.
Typical uses. Outdoor weather monitoring, smart agriculture, smart cities, gardens and urban areas, and traffic and transport management systems operating under changing outdoor conditions. The RS485 Modbus output allows integration with a PLC or a data acquisition system.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for S500, with where it comes from. Use the filters to find one quickly.
All specifications (31)
Characteristic
Value
IP rating
IP66
Accuracy
± 0.1℃
Air Humidity
0-100%RH; ±1.5%RH; resolution 0.01%RH
Air Temperature
-40°C to +85°C; ±0.1°C; resolution 0.01°C
Applications
Agriculture, smart cities, outdoor monitoring
Barometric pressure
300-1250hPa; ±50Pa; resolution 10Pa
Cable Length
3m
Device weight
2kg
Dimension
140 x 140 x 320mm
Interface
M12 connector
IP Rating / Weight
IP66; 1470g
Light Intensity
0-200,000Lux; ±5%; resolution 5Lux
Operating temp. & humidity
-40°C to +85°C; 0-100%RH
Operating Temperature & Humidity
-40 °C ~ + 85 °C, 0 ~ 100%RH
Parameters Measured
air temperature, relative humidity, barometric pressure, wind speed and wind direction
Part list
SenseCAP ONE All-in-one Compact Weather Sensor x1; M12 8-pin communication cable (default length 3-meter hook-up wire and there is a waterproof aviation connector type to choose from when working with SenseCAP SensorHub datalogger. If the aviation connector is not needed, cut it off by yourself) x1; USB Type-C cable, for configuring devices x1; Screw x6; Flat washer (to open the configuration port) x1
Power consumption
0.4W; heating 21W
Power supply
12V~24V; 24V(Heating power supply)
Product Model
S200
Protocol
RS485 (MODBUS-RTU) / SDI-12
Range
- 40 °C ~ + 85 °C
Resolution
0.01 ℃
Wind Direction
0-360°; ±3.0°; resolution 0.1°
wind direction — Accuracy
±3.0°
Wind direction range
0-360°
wind direction — Resolution
0.1°
Wind Sensor Design
Ultrasonic, no moving parts
Wind Speed
0-60m/s std.; ±0.3m/s (≤10m/s); resolution 0.1m/s
Wind speed — Accuracy
±0.3m/s (≤10m/s); ±3% (10-50m/s); ±5% (>50m/s)
Wind speed range
0-60m/s standard; 0-75m/s extended; up to 80m/s withstand
Wind speed — Resolution
0.1m/s
No specification matches.
Last verification : 2026-11-01
Technical documentation
Official documents and the technical data recorded for S500. For a missing document or a specific revision, our experts send it to you.
Compact weather sensor measuring air temperature, relative humidity, barometric pressure, wind speed and wind direction. Designed for outdoor use, with RS485 MODBUS-RTU and SDI-12 output.
Operating temp. & humidity-40°C to +85°C; 0-100%RH
Operating Temperature & Humidity-40 °C ~ + 85 °C, 0 ~ 100%RH
Range- 40 °C ~ + 85 °C
Wind direction range0-360°
InterfaceM12 connector
2. Datasheet extract (recorded values)
Parameter
Value
IP rating
IP66
Accuracy
± 0.1℃
Air Humidity
0-100%RH; ±1.5%RH; resolution 0.01%RH
Air Temperature
-40°C to +85°C; ±0.1°C; resolution 0.01°C
Applications
Agriculture, smart cities, outdoor monitoring
Barometric pressure
300-1250hPa; ±50Pa; resolution 10Pa
Cable Length
3m
Device weight
2kg
Dimension
140 x 140 x 320mm
Interface
M12 connector
IP Rating / Weight
IP66; 1470g
Light Intensity
0-200,000Lux; ±5%; resolution 5Lux
Operating temp. & humidity
-40°C to +85°C; 0-100%RH
Operating Temperature & Humidity
-40 °C ~ + 85 °C, 0 ~ 100%RH
Parameters Measured
air temperature, relative humidity, barometric pressure, wind speed and wind direction
Part list
SenseCAP ONE All-in-one Compact Weather Sensor x1; M12 8-pin communication cable (default length 3-meter hook-up wire and there is a waterproof aviation connector type to choose from when working with SenseCAP SensorHub datalogger. If the aviation connector is not needed, cut it off by yourself) x1; USB Type-C cable, for configuring devices x1; Screw x6; Flat washer (to open the configuration port) x1
Power consumption
0.4W; heating 21W
Power supply
12V~24V; 24V(Heating power supply)
Product Model
S200
Protocol
RS485 (MODBUS-RTU) / SDI-12
Range
- 40 °C ~ + 85 °C
Resolution
0.01 ℃
Wind Direction
0-360°; ±3.0°; resolution 0.1°
wind direction — Accuracy
±3.0°
Wind direction range
0-360°
wind direction — Resolution
0.1°
Wind Sensor Design
Ultrasonic, no moving parts
Wind Speed
0-60m/s std.; ±0.3m/s (≤10m/s); resolution 0.1m/s
Wind speed — Accuracy
±0.3m/s (≤10m/s); ±3% (10-50m/s); ±5% (>50m/s)
Wind speed range
0-60m/s standard; 0-75m/s extended; up to 80m/s withstand
Wind speed — Resolution
0.1m/s
Integration
Points to check before using S500 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40°C to +85°C; 0-100%RH — check it against the installation environment.
2Thermalrated operating range -40 °C ~ + 85 °C, 0 ~ 100%RH — check it against the installation environment.
Power and communication
Power consumption
0.4W; heating 21W
Power supply
12V~24V; 24V(Heating power supply)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40°C to +85°C; 0-100%RH — check it against the installation environment.
Thermal : rated operating range -40 °C ~ + 85 °C, 0 ~ 100%RH — check it against the installation environment.
Applications and use cases
Architectures in which S500 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
Power of the field devices (battery, solar)
Gateway coverage over the farm
Associated system blocks
Weather stationSoil and field sensorsGateway
Need a complete solution?
Send a request for S500 and the other parts of your project.
Answers to the questions that the recorded characteristics of S500 can answer. A question is not asked when nothing is recorded to answer it.
1Does it support RS-485?
Yes — recorded under "Protocol": RS485 (MODBUS-RTU) / SDI-12.
2Does it support Modbus?
Yes — recorded under "Protocol": RS485 (MODBUS-RTU) / SDI-12.
3Does it have a USB interface?
Yes — recorded under "Part list": SenseCAP ONE All-in-one Compact Weather Sensor x1; M12 8-pin communication cable (default length 3-meter hook-up wire and there is a waterproof aviation connector type to choose from when working with SenseCAP SensorHub datalogger. If the aviation connector is not needed, cut it off by yourself) x1; USB Type-C cable, for configuring devices x1; Screw x6; Flat washer (to open the configuration port) x1.
4What is the operating temperature range?
-40°C to +85°C; 0-100%RH (source: Operating temp. & humidity).
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSeeed Studio
S500
Compact 5-in-1 weather station with ultrasonic wind sensor
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details