Battery-powered LoRaWAN sensor measuring light intensity from 0 to 188000 lux, designed for outdoor use in harsh environments.
Operating Temperature-40 ℃ to +85 ℃
Range0 to 188000 Lux
IP ratingIP66
Battery Capacity19Ah (non-rechargeable)
Battery Life≥ 3 years (upload data once per hour)
Battery Voltage3.6V
Product overview
Overview. The Long Range -S-868-Light Intensity-01 from Seeed Studio is a wireless light intensity sensor of the SenseCAP range, transmitting its measurements over LoRaWAN on the EU868 band.
Main characteristics. The sensor measures light from 0 to 188000 lux with a resolution of 0.045 Lux and a sensitivity of 0.045 Lux/LSB. It embeds a Long Range transmitter with 16 dBm (EIRP) output and an ultra-low-power microcontroller.
Interfaces and connectivity. The device supports the LoRaWAN v1.0.2 protocol and operates in Class A. Uplink channels are 868.1, 868.3, 868.5, 867.1, 867.3, 867.5, 867.7 and 867.9 MHz, using SF7BW125 to SF12BW125 and, on 868.3 MHz, SF7BW250. The RX2 downlink uses 869.525 MHz with SF9BW125. The stated communication distance is 2 to 10 km depending on antenna and environment.
Power and environment. A non-rechargeable 19Ah battery at 3.6V powers the device, with 5 μA consumption in sleep mode and 120 mA maximum in active mode. Battery life is at least 3 years with hourly data upload. The PC enclosure is rated IP66 and resists UV according to UL746C F1. It operates from -40 ℃ to +85 ℃ and from 0 to 100 %RH non-condensing. The device weighs 288 g.
Typical uses. The sensor suits light monitoring in smart agriculture, smart building and smart city applications, as well as outdoor environmental monitoring.
Integration. The sensor is compatible with standard LoRaWAN gateways and with SenseCAP gateways. It is certified CE, FCC and RoHS.
868.1 - SF7BW125 to SF12BW125; 868.3 - SF7BW125 to SF12BW125 and SF7BW250; 868.5 - SF7BW125 to SF12BW125; 867.1 - SF7BW125 to SF12BW125; 867.3 - SF7BW125 to SF12BW125; 867.5 - SF7BW125 to SF12BW125; 867.7 - SF7BW125 to SF12BW125; 867.9 - SF7BW125 to SF12BW125
UV Resistance
anti-aging (from rain/sun exposure): UL746C F1
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for 114991727. For a missing document or a specific revision, our experts send it to you.
868.1 - SF7BW125 to SF12BW125; 868.3 - SF7BW125 to SF12BW125 and SF7BW250; 868.5 - SF7BW125 to SF12BW125; 867.1 - SF7BW125 to SF12BW125; 867.3 - SF7BW125 to SF12BW125; 867.5 - SF7BW125 to SF12BW125; 867.7 - SF7BW125 to SF12BW125; 867.9 - SF7BW125 to SF12BW125
UV Resistance
anti-aging (from rain/sun exposure): UL746C F1
Integration
Points to check before using 114991727 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40 ℃ to +85 ℃ — check it against the installation environment.
Power and communication
Current consumption
5 μA (sleep mode); 120 mA max(active mode)
Battery Capacity
19Ah (non-rechargeable)
Battery Life
≥ 3 years (upload data once per hour)
Battery Voltage
3.6V
Long Range Power Output
16 dBm (EIRP)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40 ℃ to +85 ℃ — check it against the installation environment.
Applications and use cases
Architectures in which 114991727 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for 114991727 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details