LoRaWAN EU868 wireless carbon dioxide sensor for indoor CO2 monitoring, with long-range transmission on battery power.
Operating Temperature0 ℃ to +50 ℃
ParametersCondition
Accuracy400 to 10000ppm
Battery Capacity19Ah (non-rechargeable)
Battery Life≥ 3 years (upload data once per hour)
Battery Voltage3.6V
Product overview
Overview. The SenseCAP Wireless CO2 Sensor from Seeed Studio, model LoRa-S-868-CO2-01, is an EU868 LoRaWAN sensor node for measuring carbon dioxide in indoor environments. It integrates an NDIR CO2 sensor and a LoRa transmitter based on the SX1276, and operates on the LoRaWAN v1.0.2 protocol.
Measurement. The sensor covers a range of 400 to 10000 ppm, with an accuracy specified over the same range and a temperature stability specified from 0 to 50 ℃.
Communication. The transmission distance is 2 to 10 km depending on antenna and environment. LoRa power output is 16 dBm (EIRP) and sensitivity is -137.5 dBm (SF12, BW125KHz). The LoRa channel is fixed under the EU868 channel plan.
Power and battery life. The device runs on a non-rechargeable 19 Ah battery at 3.6 V. Consumption is 5 μA in sleep mode and 120 mA maximum in active mode. With data uploaded once per hour, battery life is at least 3 years.
Environment. The data logger enclosure is rated IP66 and offers UV resistance (UL746C F1). The sensor probe is for indoor use only. The operating temperature range is 0 to 50 ℃ and the operating humidity range is 0 to 95 %RH. The device weighs 319 g.
Uses. The sensor suits CO2 monitoring in smart buildings, industrial control, precision agriculture and environmental monitoring, wherever wireless battery-powered measurement is required.
868.1 - SF7BW125 to SF12BW125; 868.3 - SF7BW125 to SF12BW125 and SF7BW250; 868.5 - SF7BW125 to SF12BW125; 867.1 - SF7BW125 to SF12BW125; 867.3 - SF7BW125 to SF12BW125; 867.5 - SF7BW125 to SF12BW125; 867.7 - SF7BW125 to SF12BW125; 867.9 - SF7BW125 to SF12BW125
UV Resistance
anti-aging (from rain/sun exposure): UL746C F1
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for 114991728. For a missing document or a specific revision, our experts send it to you.
868.1 - SF7BW125 to SF12BW125; 868.3 - SF7BW125 to SF12BW125 and SF7BW250; 868.5 - SF7BW125 to SF12BW125; 867.1 - SF7BW125 to SF12BW125; 867.3 - SF7BW125 to SF12BW125; 867.5 - SF7BW125 to SF12BW125; 867.7 - SF7BW125 to SF12BW125; 867.9 - SF7BW125 to SF12BW125
UV Resistance
anti-aging (from rain/sun exposure): UL746C F1
Integration
Points to check before using 114991728 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range 0 ℃ to +50 ℃ — check it against the installation environment.
Power and communication
Current consumption
5 μA (sleep mode); 120 mA max(active mode)
Battery Capacity
19Ah (non-rechargeable)
Battery Life
≥ 3 years (upload data once per hour)
Battery Voltage
3.6V
LoRa Power Output
16 dBm (EIRP)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range 0 ℃ to +50 ℃ — check it against the installation environment.
Applications and use cases
Architectures in which 114991728 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for 114991728 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details