LoRaWAN US915 MHz wireless carbon dioxide sensor for indoor CO2 measurement. It sends its data to a LoRaWAN gateway on a battery designed to last several years.
Operating Temperature0 ℃ to +50 ℃
ParametersCondition
Accuracy400 to 10000ppm
Battery Capacity19Ah (non-rechargeable)
Battery Life≥ 3 years (upload data once per hour)
Battery Voltage3.6V
Product overview
Seeed LoRa-S-915-CO2-01. The Seeed Studio SenseCAP Wireless CO2 Sensor is a wireless CO2 sensor operating with the LoRaWAN v1.0.2 protocol on the US915 channel plan.
Main characteristics. The sensor measures carbon dioxide concentration from 400 to 10000 ppm using NDIR technology. Its sensitivity reaches -136.5 dBm (SF12, BW125 kHz) and its LoRa power output is 16 dBm (EIRP). Communication distance is 2 to 10 km depending on the antenna and environment.
Interfaces and connectivity. The sensor communicates over LoRa on uplink channels from 903.9 to 905.3 MHz and downlink channels from 923.3 to 927.5 MHz, with spreading factors SF7 to SF12.
Power and environment. The non-rechargeable 19 Ah, 3.6 V battery provides a battery life of at least 3 years with data uploaded once per hour. Consumption is 5 µA in sleep mode and 120 mA maximum in active mode. The enclosure is made of PC, rated IP66 for the data logger, and the sensor probe is for indoor use only. Operating temperature 0 to 50 °C, operating humidity 0 to 95 %RH. Certified CE, FCC and RoHS.
Typical uses. CO2 monitoring in smart buildings, industrial sites, greenhouses and precision agriculture, as well as environmental monitoring applications.
Integration. The sensor is fully compliant with LoRaWAN specifications and works with standard LoRaWAN gateways, chosen according to the sensor frequency. Available on quotation from Atlas Electronics.
No published question about this part yet. Questions are reviewed before publication.
Complete specifications
Every characteristic recorded for 114991732, with where it comes from. Use the filters to find one quickly.
All specifications (23)
Characteristic
Value
Current consumption
5 μA (sleep mode); 120 mA max(active mode)
IP rating
IP66 (Sensor Node); Indoor (Sensor Probe)
Accuracy
400 to 10000ppm
Battery Capacity
19Ah (non-rechargeable)
Battery Life
≥ 3 years (upload data once per hour)
Battery Voltage
3.6V
Certification
CE, FCC, RoHS
Communication Distance
2 to 10 km (depending on different antennas and environments)
Device weight
319g
Downlink (MHz)
923.3 - SF7BW500 to SF12BW500; 923.9 - SF7BW500 to SF12BW500; 924.5 - SF7BW500 to SF12BW500; 925.1 - SF7BW500 to SF12BW500; 925.7 - SF7BW500 to SF12BW500; 926.3 - SF7BW500 to SF12BW500; 926.9 - SF7BW500 to SF12BW500; 927.5 - SF7BW500 to SF12BW500
Enclosure Material
PC
LoRa Channel Plan
US915
LoRa Power Output
16 dBm (EIRP)
Microcontroller
Ultra-low-power MCU
Operating Humidity
0 to 95 %RH
Operating Temperature
0 ℃ to +50 ℃
Parameters
Condition
Product Model
LoRa-S-915-CO2-01
Sensitivity
-136.5dBm(SF12, BW125KHz)
Support protocol
Based on LoRaWAN v1.0.2 protocol
Temperature stability
T = 0 to 50 ℃
Uplink (MHz)
903.9 - SF7BW125 to SF10BW125; 904.1 - SF7BW125 to SF10BW125; 904.3 - SF7BW125 to SF10BW125; 904.5 - SF7BW125 to SF10BW125; 904.7 - SF7BW125 to SF10BW125; 904.9 - SF7BW125 to SF10BW125; 905.1 - SF7BW125 to SF10BW125; 905.3 - SF7BW125 to SF10BW125
UV Resistance
anti-aging (from rain/sun exposure): UL746C F1
No specification matches.
Last verification : 2026-11-02
Technical documentation
Official documents and the technical data recorded for 114991732. For a missing document or a specific revision, our experts send it to you.
LoRaWAN US915 MHz wireless carbon dioxide sensor for indoor CO2 measurement. It sends its data to a LoRaWAN gateway on a battery designed to last several years.
Operating Temperature0 ℃ to +50 ℃
ParametersCondition
Accuracy400 to 10000ppm
Battery Capacity19Ah (non-rechargeable)
Battery Life≥ 3 years (upload data once per hour)
2. Datasheet extract (recorded values)
Parameter
Value
Current consumption
5 μA (sleep mode); 120 mA max(active mode)
IP rating
IP66 (Sensor Node); Indoor (Sensor Probe)
Accuracy
400 to 10000ppm
Battery Capacity
19Ah (non-rechargeable)
Battery Life
≥ 3 years (upload data once per hour)
Battery Voltage
3.6V
Certification
CE, FCC, RoHS
Communication Distance
2 to 10 km (depending on different antennas and environments)
Device weight
319g
Downlink (MHz)
923.3 - SF7BW500 to SF12BW500; 923.9 - SF7BW500 to SF12BW500; 924.5 - SF7BW500 to SF12BW500; 925.1 - SF7BW500 to SF12BW500; 925.7 - SF7BW500 to SF12BW500; 926.3 - SF7BW500 to SF12BW500; 926.9 - SF7BW500 to SF12BW500; 927.5 - SF7BW500 to SF12BW500
Enclosure Material
PC
LoRa Channel Plan
US915
LoRa Power Output
16 dBm (EIRP)
Microcontroller
Ultra-low-power MCU
Operating Humidity
0 to 95 %RH
Operating Temperature
0 ℃ to +50 ℃
Parameters
Condition
Product Model
LoRa-S-915-CO2-01
Sensitivity
-136.5dBm(SF12, BW125KHz)
Support protocol
Based on LoRaWAN v1.0.2 protocol
Temperature stability
T = 0 to 50 ℃
Uplink (MHz)
903.9 - SF7BW125 to SF10BW125; 904.1 - SF7BW125 to SF10BW125; 904.3 - SF7BW125 to SF10BW125; 904.5 - SF7BW125 to SF10BW125; 904.7 - SF7BW125 to SF10BW125; 904.9 - SF7BW125 to SF10BW125; 905.1 - SF7BW125 to SF10BW125; 905.3 - SF7BW125 to SF10BW125
UV Resistance
anti-aging (from rain/sun exposure): UL746C F1
Integration
Points to check before using 114991732 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range 0 ℃ to +50 ℃ — check it against the installation environment.
Power and communication
Current consumption
5 μA (sleep mode); 120 mA max(active mode)
Battery Capacity
19Ah (non-rechargeable)
Battery Life
≥ 3 years (upload data once per hour)
Battery Voltage
3.6V
LoRa Power Output
16 dBm (EIRP)
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range 0 ℃ to +50 ℃ — check it against the installation environment.
Applications and use cases
Architectures in which 114991732 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for 114991732 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details