LoRaWAN soil sensor measuring moisture, temperature and electrical conductivity (EC), intended for irrigation, greenhouses and turf and lawn management.
Operating Temperature-40 to +85 °C
Range0 to 100% (air-water)
Accuracy0 to 50%: ±3%; 50 to 100%: ±5%
IP ratingIP66
AS923AS923_1, AS923_2, AS923_3, AS923_4
AU915-928Sub-band from 1 to 8
Product overview
Overview. The Seeed Studio S2105 is a LoRaWAN soil sensor node that measures volumetric moisture from 0 to 100 %, temperature from -40 to +85 °C and soil electrical conductivity. Electrical conductivity gives the salt content of the soil, which affects crop yield and quality and the availability of nutrients to plants.
Measurement. Accuracy of ±3 % for moisture from 0 to 50 % and ±5 % from 50 to 100 %. Resolution of 0.1 % from 0 to 50 % and 0.5 % from 50 to 100 %. Measurement range 0 to 100 % (air-water).
Connectivity. LoRaWAN v1.0.3 Class A protocol, Wio-E5 microcontroller, built-in Bluetooth to change parameters with the app. Channel plans IN865, EU868, US915, AU915, AS923, KR920 and RU864, sub-bands AU915-928 and US902-928 from 1 to 8. Sensitivity of -136 dBm at SF12 BW=125 kHz, maximum transmitted power 19 dBm. Communication distance of 2 to 10 km depending on the gateway antenna and environment.
Power and environment. Standard D-size SOCl2 battery, capacity 19 Ah, non-rechargeable, battery life up to 10 years. IP66 protection rating, operating humidity 0 to 100 %RH non-condensing. Cable length 5 meters, weight 405 g. Certified CE, FCC and RoHS.
Integration. Compatible with LoRaWAN gateways and networks such as The Things Network, Loriot and Chirpstack. Supplied with 2 mounting brackets and 4 KA4×20 mm self-drilling screws.
LoRaWAN soil sensor measuring moisture, temperature and electrical conductivity (EC), intended for irrigation, greenhouses and turf and lawn management.
Operating Temperature-40 to +85 °C
Range0 to 100% (air-water)
Accuracy0 to 50%: ±3%; 50 to 100%: ±5%
IP ratingIP66
AS923AS923_1, AS923_2, AS923_3, AS923_4
2. Datasheet extract (recorded values)
Parameter
Value
IP rating
IP66
Accuracy
0 to 50%: ±3%; 50 to 100%: ±5%
AS923
AS923_1, AS923_2, AS923_3, AS923_4
AU915-928
Sub-band from 1 to 8
Battery Capacity
19Ah (non-rechargeable)
Battery Life
Up to 10 years**
Battery Type
Standard D-size SOCl2 Battery
Built-in Bluetooth
App Tool to change parameters
Cable Length
5 meters
Certification
CE / FCC / RoHS
Communication Distance
2 to10km (depending on gateway antenna and environments)
Points to check before using 114992871 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40 to +85 °C — check it against the installation environment.
Power and communication
Battery Capacity
19Ah (non-rechargeable)
Battery Life
Up to 10 years**
Battery Type
Standard D-size SOCl2 Battery
Max transmitted power
19dBm
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40 to +85 °C — check it against the installation environment.
Applications and use cases
Architectures in which 114992871 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for 114992871 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details