The Seeed Studio SenseCAP S2100 is a LoRaWAN data logger and converter that connects RS485, analog or GPIO sensors to the LoRaWAN network for outdoor environmental monitoring.
Operating Temperature-40 to +85 °C
Current input4 to 20 mA (2 channel)
Current Input Resolution (I1/I2)0. 0 0 1 m A
Frequency Plan — Common NameSub-band
IP ratingIP66
AnalogWater Leak Detector
Product overview
Overview. The Seeed Studio SenseCAP S2100 is a LoRaWAN data logger and converter (DTU) designed to transmit measurements from RS485, analog or GPIO sensors to the LoRaWAN network.
Main characteristics. IP66 enclosure, operating temperature of -40 to +85 °C, operating humidity of 0 to 100 %RH non-condensing, weight of 280 g. Powered by a 19 Ah non-rechargeable standard D-size SOCl2 battery, with a battery life of up to 10 years.
Interfaces and connectivity. LoRaWAN v1.0.3 Class A protocol, Wio-E5 microcontroller, maximum transmitted power of 19 dBm, sensitivity of -136 dBm at SF12 BW=125 kHz, communication distance of 2 to 10 km depending on site and environment. Current inputs 4 to 20 mA (2 channels), voltage inputs 0 to 10 V (2 channels), GPIO input for water leak detector, RS485 port for MODBUS-RTU sensors. Built-in Bluetooth for parameter changes and data conversion algorithm setup via app.
Frequency plans and certifications. AS923 (AS923_1 to AS923_4), AU915-928 (sub-bands 1 to 8), US902-928 (US915, sub-bands 1 to 8), IN865, EU868; certified CE, FCC and RoHS.
Typical uses. Connecting MODBUS-RTU RS485, analog or GPIO sensors to a LoRaWAN network, for precision agriculture, industrial manufacturing and smart buildings.
Integration. Compatible with public and private LoRaWAN networks and gateways; remote configuration and management through the SenseCAP Mate app and the SenseCAP Portal. Supplied with one sensor node, two brackets, a quick start guide and four KA4 × 20 mm self-drilling screws.
The Seeed Studio SenseCAP S2100 is a LoRaWAN data logger and converter that connects RS485, analog or GPIO sensors to the LoRaWAN network for outdoor environmental monitoring.
Operating Temperature-40 to +85 °C
Current input4 to 20 mA (2 channel)
Current Input Resolution (I1/I2)0. 0 0 1 m A
Frequency Plan — Common NameSub-band
IP ratingIP66
2. Datasheet extract (recorded values)
Parameter
Value
IP rating
IP66
Analog
Water Leak Detector
AS923
AS923_1, AS923_2, AS923_3, AS923_4
AU915-928 — AU915
Sub-band from 1 to 8
Battery Capacity
19Ah (non-rechargeable)
Battery Life
Up to 10 years**
Battery Type
Standard D-size SOCl2 Battery
Built-in Bluetooth
App Tool to change parameters and set data conversion algorithm
Points to check before using 114992872 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40 to +85 °C — check it against the installation environment.
Power and communication
Battery Capacity
19Ah (non-rechargeable)
Battery Life
Up to 10 years**
Battery Type
Standard D-size SOCl2 Battery
Current input
4 to 20 mA (2 channel)
Current Input Resolution (I1/I2)
0. 0 0 1 m A
Max transmitted power
19dBm
Voltage Input
0 to 10V (2 channel)
Voltage Input Resolution (V1/V2)
0. 0 1 m V
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40 to +85 °C — check it against the installation environment.
Applications and use cases
Architectures in which 114992872 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for 114992872 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSeeed Studio
114992872
LoRaWAN Data Logger with RS485, Analog and GPIO Inputs
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.