Battery-powered LoRaWAN temperature sensor with a remote PT1000 probe, designed for temperature monitoring in outdoor or harsh environments, with up to three PT1000 inputs.
Frequency Plan — Common NameSub-band
Accuracy±0.5℃
IP ratingIP66
AS923AS923_1, AS923_2, AS923_3, AS923_4
AU915-928 — AU915Sub-band from 1 to 8
Battery Capacity19Ah (non-rechargeable)
Product overview
Seeed Studio S2107 LoRaWAN temperature sensor with PT1000 probe — The Seeed Studio S2107 is a self-powered LoRaWAN sensor node that measures temperature through a PT1000 probe connected by a 3-metre cable. It suits installations where the measurement point must be remote from the enclosure, for example liquid monitoring, food monitoring or cold-chain storage.
Measurement and accuracy. The measuring range runs from -50 to 300 °C, with an accuracy of ±0.5 °C and a resolution of 0.1 °C. The cable is rated for -50 to 200 °C and the probe for -50 to 300 °C. A three-wire circuit allows up to three PT1000 probes to be connected to the same node at once.
Ruggedness and environment. The enclosure is rated IP66 and the radio unit operates from -40 to 85 °C, at 0 to 100 %RH humidity, non-condensing. The manufacturer indicates outdoor use, high UV exposure, heavy rain and dusty conditions.
LoRaWAN radio and range. The sensor implements LoRaWAN v1.0.3 Class A and supports the IN865, EU868, US915, AU915, AS923, KR920 and RU864 channel plans. Sensitivity is -136 dBm at SF12 with a 125 kHz bandwidth, and maximum transmitted power is 19 dBm. The stated communication distance is 2 to 10 km, depending on the environment and the gateway antenna.
Power and battery life. Power comes from a non-rechargeable 19 Ah standard D-size SOCl2 battery, with a battery life of up to 10 years. The device weighs 360 g.
Configuration. Built-in Bluetooth lets you change parameters and perform calibration from the SenseCAP Mate app, with no programming tool required. The product is certified CE, FCC, RoHS and TELEC.
Battery-powered LoRaWAN temperature sensor with a remote PT1000 probe, designed for temperature monitoring in outdoor or harsh environments, with up to three PT1000 inputs.
Frequency Plan — Common NameSub-band
Accuracy±0.5℃
IP ratingIP66
AS923AS923_1, AS923_2, AS923_3, AS923_4
AU915-928 — AU915Sub-band from 1 to 8
2. Datasheet extract (recorded values)
Parameter
Value
IP rating
IP66
Accuracy
±0.5℃
AS923
AS923_1, AS923_2, AS923_3, AS923_4
AU915-928 — AU915
Sub-band from 1 to 8
Battery Capacity
19Ah (non-rechargeable)
Battery Life
Up to 10 years**
Battery Type
Standard D-size SOCl2 Battery
Built-in Bluetooth
App Tool to change parameters
Cable Length
3 meters
Certification
CE / FCC / RoHS / TELEC
Communication Distance
2 to 10 km (depending on gateway antenna and environments
Device weight
360g
Frequency Plan — Common Name
Sub-band
LoRaWAN Channel Plan
IN865/EU868/US915/AU915/ AS923/KR920/RU864 *
Max transmitted power
19dBm
Microcontroller
Wio-E5
Operating Humidity
0 to 100 %RH (non-condensing)
Operating Temperature
-40 to +85 °C (LoRa DTU); -50 to 200℃(Cable); -50 to 300℃ (Probe)
-50 to 300 ℃; (Other range customization contact sales)
Resolution
0.1℃
Sensitivity
-136dBm@SF12 BW=125KHz
Support protocol
LoRaWAN v1.0.3 Class A
US902-928 — US915
Sub-band from 1 to 8
Applications and use cases
Architectures in which 114993078 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for 114993078 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSeeed Studio
114993078
LoRaWAN temperature sensor with PT1000 probe, IP66
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details