Industrial photosynthetically active radiation (PAR) sensor from Seeed Studio with Modbus-RTU RS485 output and waterproof aviation connector, for light monitoring in natural environments.
Operating Temperature-30 ~ +75 ℃
Measuring Range0 ~ 2500 μmol/m²·s
InterfaceRS-485
Supply voltage5V ~24V
Accuracy±0.1 ℃
Measurement Accuracy±2%
Product overview
Overview. The Seeed Studio S-PAR-02B industrial PAR sensor measures real-time photosynthetically active radiation (PAR) across the 400 to 700 nm range. It contains a silicon photodetector and generates a voltage signal directly proportional to PAR, expressed in μmol/m²·s, with a measuring range of 0 to 2500 μmol/m²·s and a resolution of 1 μmol/m²·s.
Main characteristics. Measurement accuracy of ±2%, linearity with a maximum deviation of 1%, response time of 10 μs, measurement interval of 1 s and yearly stability. The cosine response is at most 10% (deviation of 10° from the ideal value on a clear day).
Interfaces and connectivity. RS-485 output using the Modbus-RTU protocol, compatible with RS485 data loggers and digital voltmeters. 2 m cable with waterproof aviation connector. A 0-2.5 V analog voltage output version can be customised.
Power and environment. Supply voltage of 5 V to 24 V, IP66 protection rating, operating temperature range of -30 to +75 °C and humidity of 0 to 100 %RH non-condensing. PC enclosure, probe 70 mm long and 3 mm in diameter.
Typical uses. Light monitoring for research and agriculture, integrated into industrial supervision systems via Modbus RTU.
Integration. Compatible with the SenseCAP Sensor Hub 4G Data Logger for collecting several sensors and sending the data over 3G/4G LTE.
Industrial photosynthetically active radiation (PAR) sensor from Seeed Studio with Modbus-RTU RS485 output and waterproof aviation connector, for light monitoring in natural environments.
Operating Temperature-30 ~ +75 ℃
Measuring Range0 ~ 2500 μmol/m²·s
InterfaceRS-485
Supply voltage5V ~24V
Accuracy±0.1 ℃
2. Datasheet extract (recorded values)
Parameter
Value
IP rating
IP66
Supply voltage
5V ~24V
Response time
10 μs
Accuracy
±0.1 ℃
Cable Length
2m
Communication Protocol for Sensor
Modbus-RTU RS485
Cosine response
≤10%(Deviation of sun height of 10° from ideal value on clear day)
Data Upload
SenseCAP Portal(default) User's Server (MQTT Server)
Device weight
1600g
Device Weight(NW)
876g
ECTDS Sensor
Water Electrical Conductivity, Total Dissolved Solids
Switching power supply Red LED indicates equipment status
Wall Power
DC 12V/2A
Integration
Points to check before using 314990735 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Powerplan for a supply compatible with 5V ~24V.
2Thermalrated operating range -30 ~ +75 ℃ — check it against the installation environment.
Power and communication
Supply voltage
5V ~24V
Power Supply for Sensor
5V/12V (depending on sensor types)
Solar Power (optional)
Maximum power: 12wp size: 340*255mm
Wall Power
DC 12V/2A
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Power : plan for a supply compatible with 5V ~24V.
Thermal : rated operating range -30 ~ +75 ℃ — check it against the installation environment.
Applications and use cases
Architectures in which 314990735 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
A proprietary PLC locks the project into one vendor’s tools. Industrial controllers built on the Raspberry Pi Compute Module run Linux, Node-RED, Python or CODESYS on DIN rail, with I/O modules, an operator panel and a cellular router for remote access
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Current productSeeed Studio
314990735
Industrial PAR Sensor with Modbus-RTU RS485 and Aviation Connector
Industrial pH Sensor MODBUS-RTU RS485 & 0-2V Analog Voltage (S-pH-01B), with waterproof aviation connector
A
Yes, the device is fully calibrated prior to shipment from the factory.; About calibration, please refer to the document :; https://raw.githubusercontent.com/Jenkinlu001/SenseCAP/master/PH10-AppNote-PH%20Calibration%20by%20Modbus%20Command.doc
Accuracy
± 0.1 pH
Cable Length
Power and Signal Cable:2 meters (Customizable); Electrode Cable: 5 meters