The Seeed Studio S2106 LoRaWAN pH sensor measures the acidity or basicity of water-based solutions and transmits readings over LoRaWAN networks. It targets water monitoring and outdoor environments.
Operating Temperature-40 to +85 °C
Range0 to 14 pH
Frequency Plan — Common NameSub-band
Accuracy±0.1 pH
AS923AS923_1, AS923_2, AS923_3, AS923_4
AU915-928 — AU915Sub-band from 1 to 8
Product overview
Seeed Studio S2106 is a LoRaWAN pH sensor node made of a DTU unit, a junction box and an immersible probe. It measures pH over a range of 0 to 14 with an accuracy of ±0.1 pH and a resolution of 0.01 pH.
Main characteristics. Powered by a non-rechargeable 19 Ah D-size SOCl2 battery, with a battery life of up to 10 years. Operating temperature from -40 to +85 °C and operating humidity from 0 to 100 %RH, non-condensing. IP66 protection for the DTU, IP65 for the junction box and IP68 for the sensor probe.
Connectivity. LoRaWAN v1.0.3 Class A protocol with AS923, AU915 and US915 frequency plans, and IN865, EU868, KR920 and RU864 listed in the channel plans. Sensitivity of -136 dBm at SF12 BW=125 kHz, maximum transmitted power of 19 dBm and communication distance of 2 to 10 km depending on gateway antenna and environment. Built-in Bluetooth to change parameters with an app.
Installation and maintenance. 2-meter cable between the DTU and the junction box, and 5-meter cable between the junction box and the probe. Device weight of 600 g. The probe should be cleaned every 3 to 6 months and calibrated every 6 to 12 months. Certifications CE, FCC and RoHS.
Typical uses. Water quality monitoring in sewage treatment plants, swimming pools and spas, rivers and hydroponic systems, as well as livestock buildings and scientific experiments, where a LoRaWAN network covers the site. Available on quotation from Atlas Electronics.
The Seeed Studio S2106 LoRaWAN pH sensor measures the acidity or basicity of water-based solutions and transmits readings over LoRaWAN networks. It targets water monitoring and outdoor environments.
Points to check before using S2106 in a design. They are derived from the recorded characteristics, not from the manufacturer's application circuits.
1Thermalrated operating range -40 to +85 °C — check it against the installation environment.
Power and communication
Battery Capacity
19Ah (non-rechargeable)
Battery Life
Up to 10 years***
Battery Type
Standard D-size SOCl2 Battery
Max transmitted power
19dBm
Check the exact pin assignment and the application circuit in the datasheet, or ask our experts.
Implementation checklist
Thermal : rated operating range -40 to +85 °C — check it against the installation environment.
Applications and use cases
Architectures in which S2106 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Diseases and water stress are noticed once the crop is already affected. A weather station, soil probes and sensor nodes in the field report conditions through an outdoor gateway
To check
Crops, plots and measurement depth of the soil probes
A LoRaWAN project needs sensors, gateways, a network server and an application that work together. Sensor nodes report to indoor or outdoor gateways, which forward the data to the network server and the customer’s platform
To check
Regional frequency plan (EU868, US915 and others)
Network server: public, private or embedded in the gateway
Milesight sensors, LoRaWAN gateways and cellular routers can be brought together on the Milesight Development Platform, which manages the devices and passes their data to other applications through an API and webhooks
To check
Development Platform for device management, API and webhooks, or another network server and application
Devices provisioned through Milesight RPS must have that provisioning removed before being added to the Development Platform
Data flows to the customer’s own application through webhooks
RAKwireless WisGate gateways run WisGateOS 2 and are managed from WisDM, RAKwireless’ cloud device management platform with a built-in network server, alongside RAK sensor nodes, radio modules and concentrators
To check
WisDM built-in network server, or a third-party one (ChirpStack, TTN/TTS, AWS IoT Core, Actility)
Remote configuration and updates of the gateways from WisDM
Regional frequency plan of the gateways and nodes
Associated system blocks
GatewaysSensors and modulesDevelopment boardsMounting
Seeed SenseCAP sensors connect to Seeed’s SenseCAP cloud platform and app, and Seeed edge computers, camera modules, Grove and XIAO boards complete the chain for custom devices and local processing
To check
SenseCAP cloud platform and app, or the customer’s own network server
Prototype on Grove and XIAO, then move to industrial versions
Local processing on the edge computers or in the cloud
Associated system blocks
SensorsEdge computingDevelopment boards
Need a complete solution?
Send a request for S2106 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
SenseCAP SOLO CO2 5000 (A1) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
SenseCAP SOLO CO2 5000 (A2) - NDIR CO2 Sensor, MODBUS-RTU RS485 & SDI-12, with Waterproof Aviation Connector
A
The default output of the sensor is RS485 and the slave address is 1. If you need to use SDI-12 output, you need to open the cover and push the button on the board to ''1'' and ''2''. At the same time, check whether the wire sequence is correct.
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details