MD61 – Thermal conduction gas sensor for methane, hydrogen and inert gases

Thermal conduction gas sensor for methane, hydrogen and inert gases

Methane Sensors

  • 0~100%
  • ≤ 120 mA
  • -20—+70℃, <70%RH
  • Thermal conduction
Manufacturer part number
MD61
Manufacturer
Winsen
Detection range
0~100%
Working current(mA)
≤ 120 mA

Winsen MD61 thermal conduction gas sensor for detecting methane, hydrogen and inert gases on industrial sites, with a linear output signal.

Product overview

Overview. The Winsen MD61 is a thermal conduction gas sensor for detecting methane, hydrogen and inert gases on industrial sites. It operates on the principle that the overall thermal conductivity of a gas mixture changes with the concentration of the gas analysed. A detection element and a compensation element form one arm of a bridge, and the bridge output voltage increases proportionally with concentration.

Main characteristics. The detection range is 0 to 100%. Sensitivity is greater than or equal to 15 mV per 10% CH4, linearity is less than or equal to 8%, response time (90%) is less than or equal to 10 s and resume time (90%) is less than or equal to 30 s. The sensor offers good repeatability and reliable performance, with no catalyst poisoning, and can detect without oxygen or with low oxygen levels.

Power and environment. The working voltage is 3.0 ± 0.1 V DC, with a working current less than or equal to 120 mA. The sensor is designed for use between -20 and +50 °C at a relative humidity below 95%, and for storage between -20 and +70 °C at a relative humidity below 70%. The explosion-proof mark is ExdibⅠ and the dimensions are 19 × 9.5 × 14 mm.

Typical uses and integration. The MD61 suits gas detection on industrial sites. Its linear output signal eases integration into a measurement chain or monitoring device. A sleep mode can be implemented in programming if needed, as the sensor has no built-in sleep mode.

See all specifications

Highlights

  • Characteristics: Good re-peatability and reliable performance
  • Detection Gas: Methane, hydrogen, inert gases
  • Detection Principle: Thermal conduction
  • Detection range: 0~100%
  • Dimension(mm): 19×9.5×14
  • Explosion-proof mark: ExdibⅠ

See also

Technical questions

Ask a question

No published question about this part yet. Questions are reviewed before publication.

Similar products

All Methane Sensors
Request a quote