MD61
Thermal conduction gas sensor for methane, hydrogen and inert gases

- Detection range
- 0~100%
- Working current(mA)
- ≤ 120 mA
- Storage Environment
- -20—+70℃, <70%RH
- Standard package
- Metallurgical powder network
Thermal conduction gas sensor for methane, hydrogen and inert gases
Winsen MD61 thermal conduction gas sensor for detecting methane, hydrogen and inert gases on industrial sites, with a linear output signal.
Overview. The Winsen MD61 is a thermal conduction gas sensor for detecting methane, hydrogen and inert gases on industrial sites. It operates on the principle that the overall thermal conductivity of a gas mixture changes with the concentration of the gas analysed. A detection element and a compensation element form one arm of a bridge, and the bridge output voltage increases proportionally with concentration.
Main characteristics. The detection range is 0 to 100%. Sensitivity is greater than or equal to 15 mV per 10% CH4, linearity is less than or equal to 8%, response time (90%) is less than or equal to 10 s and resume time (90%) is less than or equal to 30 s. The sensor offers good repeatability and reliable performance, with no catalyst poisoning, and can detect without oxygen or with low oxygen levels.
Power and environment. The working voltage is 3.0 ± 0.1 V DC, with a working current less than or equal to 120 mA. The sensor is designed for use between -20 and +50 °C at a relative humidity below 95%, and for storage between -20 and +70 °C at a relative humidity below 70%. The explosion-proof mark is ExdibⅠ and the dimensions are 19 × 9.5 × 14 mm.
Typical uses and integration. The MD61 suits gas detection on industrial sites. Its linear output signal eases integration into a measurement chain or monitoring device. A sleep mode can be implemented in programming if needed, as the sensor has no built-in sleep mode.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for MD61, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Characteristics | Good re-peatability and reliable performance |
| Detection Gas | Methane, hydrogen, inert gases |
| Detection Principle | Thermal conduction |
| Detection range | 0~100% |
| Dimension(mm) | 19×9.5×14 |
| Explosion-proof mark | ExdibⅠ |
| Linearity | ≤ 8% |
| Model | MD61 |
| Part No. | MD61 |
| Response time (90%) | ≤ 10 s |
| Resume time (90%) | ≤ 30 s |
| Sensitivity (mV/10%CH4) | ≥ 15 |
| Size | 19×9.5×14 |
| Standard package | Metallurgical powder network |
| Storage Environment | -20—+70℃, <70%RH |
| Target | Methane, hydrogen, inert gases |
| Type | Thermal conduction |
| Using Environment | -20-+50℃, <95%RH |
| Working current(mA) | ≤ 120 mA |
| Working Voltage (V) | 3.0±0.1 (DC) |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for MD61. For a missing document or a specific revision, our experts send it to you.
Winsen MD61 thermal conduction gas sensor for detecting methane, hydrogen and inert gases on industrial sites, with a linear output signal.
| Parameter | Value |
|---|---|
| Characteristics | Good re-peatability and reliable performance |
| Detection Gas | Methane, hydrogen, inert gases |
| Detection Principle | Thermal conduction |
| Detection range | 0~100% |
| Dimension(mm) | 19×9.5×14 |
| Explosion-proof mark | ExdibⅠ |
| Linearity | ≤ 8% |
| Model | MD61 |
| Part No. | MD61 |
| Response time (90%) | ≤ 10 s |
| Resume time (90%) | ≤ 30 s |
| Sensitivity (mV/10%CH4) | ≥ 15 |
| Size | 19×9.5×14 |
| Standard package | Metallurgical powder network |
| Storage Environment | -20—+70℃, <70%RH |
| Target | Methane, hydrogen, inert gases |
| Type | Thermal conduction |
| Using Environment | -20-+50℃, <95%RH |
| Working current(mA) | ≤ 120 mA |
| Working Voltage (V) | 3.0±0.1 (DC) |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Thermal conduction gas sensor for methane, hydrogen and inert gases

Explosion-proof Methane Gas Detector Sensor with Audible-Visual Alarm

HENGKO flameproof combustible gas leak detection housing for atmospheric monitoring system

ICP DAS I

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | MD61 |
| Manufacturer | Winsen |
Methane Sensors
Natural gas (methane) detector with CAN Bus interface · Ref. : CL-20A-C
Price on request
Methane Sensors
MEMS combustible methane gas sensor · Ref. : RS-CH01
Price on request
Methane Sensors
MEMS methane CH4 gas detection sensor (breakout) · Ref. : SEN0565
Price on request
Methane Sensors
Flammable gas MOS sensor for propane, LPG and methane · Ref. : MQ-5B
Price on request
No advertising or analytics cookies. A single, strictly necessary cookie is set only if you sign in to your account. Your quote basket and comparison stay in your browser. Details