Winsen ME3-HF electrochemical sensor for hydrogen fluoride (HF) measurement in industrial and environmental protection applications, over a 0 to 10 ppm range.
Pressure rangeStandard atmospheric pressure±10%
Detection range0-10ppm, Max 100ppm
Measurement Range0~10ppm
Storage humidity15%~90% RH
Storage Temperature-20℃~50℃
Anticipated using life2 years (in air)
Product overview
Winsen ME3-HF electrochemical gas sensor. The ME3-HF is an electrochemical gas sensor designed to detect hydrogen fluoride (HF). It measures gas concentration from the current produced by electrochemical oxidation of the target gas on the working electrode, this current being proportional to concentration according to Faraday's law.
Main characteristics. Measurement range of 0 to 10 ppm with a maximum detectable concentration of 100 ppm, resolution of 0.1 ppm, sensitivity of (0.4±0.15) µA/ppm and linear output. The T90 response time is less than or equal to 90 s and zero drift between -20 and 40 °C is less than or equal to 0.2 ppm.
Stability and service life. Repeatability below 2% of the output value, stability below 2% per month and an anticipated service life of 2 years in air. The sensor operates at standard atmospheric pressure ±10%.
Environmental conditions. Storage between -20 °C and 50 °C, at a relative humidity between 15% and 90% RH. Temperatures or humidity outside these ranges, or prolonged exposure to high temperature and high humidity, will reduce the sensor's service life.
Dimensions and integration. Size φ20×16.4 mm. Recommended load resistance of 10 Ω. The sensor has no sleep mode, which can be set in the program if needed. It should be aged and calibrated by the user once stable, according to the whole device's program and use.
Typical applications. Monitoring of hydrogen fluoride in industrial environments and environmental protection.
Winsen ME3-HF electrochemical sensor for hydrogen fluoride (HF) measurement in industrial and environmental protection applications, over a 0 to 10 ppm range.
Pressure rangeStandard atmospheric pressure±10%
Detection range0-10ppm, Max 100ppm
Measurement Range0~10ppm
Storage humidity15%~90% RH
Storage Temperature-20℃~50℃
2. Datasheet extract (recorded values)
Parameter
Value
Pressure range
Standard atmospheric pressure±10%
Anticipated using life
2 years (in air)
Bias voltage
0mV
Characteristics
Detection of hydrogen fluoride in industrial and environmental protection fields
Detection Gas
HF
Detection Principle
Electrochemical
Detection range
0-10ppm, Max 100ppm
Load resistance(recommend)
10&Omega
Max detecting concentration
100ppm
Measurement Range
0~10ppm
Model
ME3-HF
Output Linearity
Linear
Repeatability
<2% output value
Resolution ratio
0.1ppm
Response Time (T90)
≤ 90S
Sensitivity
(0.4±0.15) µA/ppm
Size
φ20×16.4
Stability (/month)
<2%
Storage humidity
15%~90% RH
Storage Temperature
-20℃~50℃
Target
HF
Working Conditions
Resolution ratio 0.1ppm; Response time≤90s; Anticipated using life 2 years
Zero drift (-20~40℃)
≤ 0.2ppm
Applications and use cases
Architectures in which ME3-HF can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for ME3-HF and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details