ME4-H2S
Electrochemical hydrogen sulfide H2S gas sensor

- Temperature range
- -20℃~50℃
- Pressure range
- standard atmospheric pressure±10%
- Humidity range
- 15%~90%RH
- Detection range
- 0-100ppm, Max 500ppm
Electrochemical hydrogen sulfide H2S gas sensor
Constant-potential electrochemical sensor for hydrogen sulfide (H2S) detection in industrial, mining and environmental protection applications.
Overview. The Winsen ME4-H2S is a constant-potential electrochemical hydrogen sulfide gas sensor designed for H2S detection. Its principle relies on an oxidation-reduction reaction between hydrogen sulfide and oxygen, generating a current proportional to the target gas concentration.
Main characteristics. The sensor covers a 0 to 100 ppm range, with a maximum of 500 ppm and a resolution of 0.1 ppm. Its sensitivity is (0.8 ± 0.15) µA/ppm, with linear output, repeatability below 2% of the output value and stability below 2% per month. The T90 response time is under 30 s and the zero drift (-20 to 40 ℃) is at most 0.2 ppm. The anticipated service life is 2 years in air.
Power and environment. The sensor operates from -20 ℃ to 50 ℃ and from 15% to 90% RH, without condensation, at standard atmospheric pressure ±10%. The recommended load resistance is 10 Ω. Its size is φ32 × 14.5.
Typical uses. This sensor is intended for H2S detection in industrial, mining and environmental protection applications.
Integration. Its low power consumption and current output make it suitable for integration into measurement systems. The data do not specify a digital communication interface.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for ME4-H2S, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Pressure range | standard atmospheric pressure±10% |
| Humidity range | 15%~90%RH |
| Bias voltage | 0mV |
| Characteristics | Detection of hydrogen sulfide in industrial, underground mining and environmental protection fields |
| Detection Gas | Hydrogen Sulfide (H2S) |
| Detection Principle | Electrochemical |
| Detection range | 0-100ppm, Max 500ppm |
| Life span | 2 years (in air) |
| Load Resistance | 10Ω (recommended) |
| Max Range | 500ppm |
| Model | ME4-H2S |
| Output Linearity | Linear |
| Repeatability | <2% Output value |
| Resolution | 0.1ppm |
| Response Time (T90) | <30S |
| Sensitivity | (0.8±0.15) µA/ppm |
| Size | φ32×14.5 |
| Stability (/month) | <2% |
| Target | H2S |
| Temperature range | -20℃~50℃ |
| Working Conditions | Resolution ratio 0.1ppm; Response time<30s; Anticipated using life 2 years |
| Zero drift (-20~40℃) | ≤ 0.2ppm |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for ME4-H2S. For a missing document or a specific revision, our experts send it to you.
Constant-potential electrochemical sensor for hydrogen sulfide (H2S) detection in industrial, mining and environmental protection applications.
| Parameter | Value |
|---|---|
| Pressure range | standard atmospheric pressure±10% |
| Humidity range | 15%~90%RH |
| Bias voltage | 0mV |
| Characteristics | Detection of hydrogen sulfide in industrial, underground mining and environmental protection fields |
| Detection Gas | Hydrogen Sulfide (H2S) |
| Detection Principle | Electrochemical |
| Detection range | 0-100ppm, Max 500ppm |
| Life span | 2 years (in air) |
| Load Resistance | 10Ω (recommended) |
| Max Range | 500ppm |
| Model | ME4-H2S |
| Output Linearity | Linear |
| Repeatability | <2% Output value |
| Resolution | 0.1ppm |
| Response Time (T90) | <30S |
| Sensitivity | (0.8±0.15) µA/ppm |
| Size | φ32×14.5 |
| Stability (/month) | <2% |
| Target | H2S |
| Temperature range | -20℃~50℃ |
| Working Conditions | Resolution ratio 0.1ppm; Response time<30s; Anticipated using life 2 years |
| Zero drift (-20~40℃) | ≤ 0.2ppm |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Electrochemical hydrogen sulfide H2S gas sensor

Hydrogen Sulfide Gas Sensor

Hydrogen Sulfide Gas Sensor

Industrial-grade MODBUS RS485 H2S Sensor - with Waterproof Aviation Connector

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | ME4-H2S |
| Manufacturer | Winsen |
H2S Sensors
Industrial H2S Sensor RS485 Modbus RTU with Waterproof Connector · Ref. : 101990863
Price on request
H2S Sensors
LoRaWAN washroom odor sensor with NH3 and H2S sensing
Price on request
H2S Sensors
H2S Gas Sensor, MEMS, 0.5-50 ppm Detection Range · Ref. : SEN0568
Price on request
H2S Sensors
Electrochemical hydrogen sulfide H2S gas sensor · Ref. : ME3-H2S
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details