Winsen constant-potential electrochemical nitrogen dioxide (NO2) gas sensor for NO2 detection in industrial, mining and environmental protection applications.
Temperature range-20℃~50℃
Pressure rangestandard atmospheric pressure±10%
Humidity range15%~90% RH
Detection range0-20ppm, Max 150ppm
Max Range150ppm
Bias voltage10Ω (recommended)
Product overview
Overview. The Winsen ME4-NO2 is a constant-potential electrolysis type electrochemical nitrogen dioxide (NO2) gas sensor. An oxidation-reduction reaction takes place on the working electrode and on the counter electrode; the current generated is proportional to the NO2 concentration, so the concentration of the target gas is determined by measuring this current.
Main characteristics. Detection range of 0 to 20 ppm, maximum 150 ppm, with a resolution of 0.1 ppm. Sensitivity is (1.2±0.3) µA/ppm, with linear output and repeatability better than 2% of the output value. Response time T90 is under 30 s and stability is under 2% per month. Zero drift is 0.2 ppm between -20 and 40 °C.
Power and environment. The sensor operates over a temperature range of -20 to 50 °C and a humidity range of 15 to 90% RH without condensation. Working pressure is standard atmospheric pressure ±10%. The recommended bias voltage is 10 Ω. Anticipated service life is 2 years in air. Size: φ32×14.5.
Typical uses. Nitrogen dioxide detection in industrial, mining and environmental protection applications, where low power consumption, high precision and good anti-interference ability are key features.
Integration. The sensor has no sleeping mode; one can be set in the program if needed. The sensor is tested but not calibrated before leaving the factory; calibration after stabilisation is recommended according to the conditions of use of the complete device.
Winsen constant-potential electrochemical nitrogen dioxide (NO2) gas sensor for NO2 detection in industrial, mining and environmental protection applications.
Temperature range-20℃~50℃
Pressure rangestandard atmospheric pressure±10%
Humidity range15%~90% RH
Detection range0-20ppm, Max 150ppm
Max Range150ppm
2. Datasheet extract (recorded values)
Parameter
Value
Pressure range
standard atmospheric pressure±10%
Humidity range
15%~90% RH
Bias voltage
10Ω (recommended)
Characteristics
Detection of nitrogen dioxide in industrial, underground mining and environmental protection fields
Detection Gas
Nitrogen dioxide (NO2)
Detection Principle
Electrochemical
Detection range
0-20ppm, Max 150ppm
Life span
2 years (in air)
Load Resistance
0mV
Max Range
150ppm
Model
ME4-NO2
Output Linearity
Linear
Repeatability
<2% Output value
Resolution
0.1ppm
Response Time (T90)
<30S
Sensitivity
(1.2±0.3) µA/ppm
Size
φ32×14.5
Stability (/month)
<2%
Target
NO2
Temperature range
-20℃~50℃
Working Conditions
Resolution ratio 0.1ppm; Response time<30s; Anticipated using life 2 years
Zero drift (-20~40℃)
0.2ppm
Applications and use cases
Architectures in which ME4-NO2 can play a role, derived from its category. This is not a compatibility statement: check the specifications against your requirements.
Offices and classrooms get stuffy without anyone measuring why. Indoor air quality monitoring places CO2, VOC and particle sensors in the rooms and reports their values through a gateway, so ventilation can be adjusted to real occupancy
To check
Parameters to measure (CO2 alone or CO2, VOC and particles)
Battery-powered sensors or mains-powered sensors with display
Integration with the ventilation control or building management system
Associated system blocks
Air sensorsGateway
Need a complete solution?
Send a request for ME4-NO2 and the other parts of your project.
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Urban atmosphere and enterprise environmental monitoring, unorganized emission pollution gas monitoring in factories, emergency monitoring, environmental assessment and monitoring
What is recorded about the regulatory status and the life of this part.
Regulatory compliance
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details