MH-741A
Infrared CH4 methane gas sensor with IIC output

- Detection range
- 0~100%VOL optional
- Measurement Range
- 0~100%VOL optional (view table 2)
- Interface Level
- 3.3V
- Average Current
- < 100mA
Infrared CH4 methane gas sensor with IIC output
Winsen MH-741A NDIR infrared gas sensor for detecting CH4 methane and combustible gases, with IIC output, for industrial instrumentation and safety protection.
Overview. The Winsen MH-741A is an NDIR (non-dispersive infrared) gas sensor designed to detect CH4 methane, natural gas and combustible gases. It has built-in temperature compensation and does not depend on oxygen.
Main characteristics. Measurement range of 0 to 100 %VOL optional, T90 response time below 30 s, warm-up time of 3 min, lifespan above 5 years. The sensor offers high sensitivity, high resolution and low power consumption, with excellent linear output and resistance to poisons and vapour interference.
Interfaces and connectivity. IIC digital output, 3.3 V interface level.
Power and environment. Working voltage 4.5 V to 5.5 V DC, average current below 100 mA. Working temperature -40 ℃ to 70 ℃, working humidity 0 to 95 %RH non-condensing. Protection class IP65, dimensions Φ44×61 mm, weight 350 g.
Certification. Ex-marking Ex d ⅡC T6 Gb, suited to detecting combustible gases in explosive areas.
Typical uses. Industrial field instrumentation, industrial-process control and safety protection.
Manufacturer note. This product is listed by the manufacturer as discontinued; the updated model is the MH-T7042A.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for MH-741A, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Response time | T90 < 30s |
| Average Current | < 100mA |
| Characteristics | High sensitivity, high resolution, low power consumption |
| Detection Principle | NDIR |
| Detection range | 0~100%VOL optional |
| Dimension | Φ 44×61mm |
| Ex-marking | Ex d ⅡC T6 Gb |
| Gas detected | CH4,C3H8... Combustible gas (see manual table 2 for details) |
| Interface Level | 3.3V |
| Lifespan | >5 years |
| Measurement Range | 0~100%VOL optional (view table 2) |
| Model | MH-741A |
| Notes | This product has been discontinued, Updated Model No.: MH-T7042A |
| Output signal | IIC |
| Product Model | MH-741A |
| Protected Class | IP65 |
| Size | Φ44×61mm |
| Target | CH4 methane, natural gas, combustible gas |
| Warm-Up Time | 3min |
| Weight | 350g |
| Working humidity | 0 to 95%RH, non-condensing |
| Working temperature | -40℃ ~ 70℃ |
| Working voltage | 4.5 V ~ 5.5V DC |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for MH-741A. For a missing document or a specific revision, our experts send it to you.
Winsen MH-741A NDIR infrared gas sensor for detecting CH4 methane and combustible gases, with IIC output, for industrial instrumentation and safety protection.
| Parameter | Value |
|---|---|
| Response time | T90 < 30s |
| Average Current | < 100mA |
| Characteristics | High sensitivity, high resolution, low power consumption |
| Detection Principle | NDIR |
| Detection range | 0~100%VOL optional |
| Dimension | Φ 44×61mm |
| Ex-marking | Ex d ⅡC T6 Gb |
| Gas detected | CH4,C3H8... Combustible gas (see manual table 2 for details) |
| Interface Level | 3.3V |
| Lifespan | >5 years |
| Measurement Range | 0~100%VOL optional (view table 2) |
| Model | MH-741A |
| Notes | This product has been discontinued, Updated Model No.: MH-T7042A |
| Output signal | IIC |
| Product Model | MH-741A |
| Protected Class | IP65 |
| Size | Φ44×61mm |
| Target | CH4 methane, natural gas, combustible gas |
| Warm-Up Time | 3min |
| Weight | 350g |
| Working humidity | 0 to 95%RH, non-condensing |
| Working temperature | -40℃ ~ 70℃ |
| Working voltage | 4.5 V ~ 5.5V DC |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Infrared CH4 methane gas sensor with IIC output

Explosion-proof Methane Gas Detector Sensor with Audible-Visual Alarm

HENGKO flameproof combustible gas leak detection housing for atmospheric monitoring system

ICP DAS I

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | MH-741A |
| Manufacturer | Winsen |
Methane Sensors
Natural gas (methane) detector with CAN Bus interface · Ref. : CL-20A-C
Price on request
Methane Sensors
MEMS combustible methane gas sensor · Ref. : RS-CH01
Price on request
Methane Sensors
MEMS methane CH4 gas detection sensor (breakout) · Ref. : SEN0565
Price on request
Methane Sensors
Flammable gas MOS sensor for propane, LPG and methane · Ref. : MQ-5B
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details