MQ-4B
Flammable gas MOS sensor for methane CH4

- Detection range
- 300-10000ppm
- Detection Principle
- Semiconductor
- Life span
- 10 years
- Model
- MQ-4B
Flammable gas MOS sensor for methane CH4
Winsen MQ-4B MOS semiconductor sensor for detecting methane CH4, natural gas and flammable gases, for leak alarms and portable gas detectors.
Overview. The Winsen MQ-4B is a MOS semiconductor flammable gas sensor designed to detect methane CH4 over a range of 300 to 10000ppm. Its SnO2 sensitive material increases in conductivity as the target gas concentration rises, and a simple circuit converts this change into an output signal.
Main characteristics. The sensor offers high sensitivity to methane and strong anti-interference ability, including against alcohol and other gases. Its life span is 10 years. Its sensor resistance under standard test conditions is 28Ω ±3Ω at room temperature, at 20℃ ±2℃ and 55% ±5%RH. The standard encapsulation is plastic and the size is φ16.7×9.4.
Power and environment. The standard circuit operates at 5.0V ±0.1VDC. Loop voltage is 5 ±0.1V, heater voltage is 5 ±0.1V, and heater consumption is ≤1W. The manufacturer specifies a humidity range of 15% to 90% RH without condensation; conditions outside this range, or prolonged high temperature and high humidity, affect the sensor life.
Typical uses. The MQ-4B is intended for domestic gas leakage alarms, industrial flammable gas alarms and portable gas detectors. It provides good sensitivity to methane over a wide range with a simple drive circuit.
Integration. The manufacturer recommends aging and calibrating the sensor once it has stabilised, according to the program and operating conditions of the complete device, as the sensor is tested but not calibrated before leaving the factory. The sensors have no sleeping mode, but one can be set in the program if needed.
No published question about this part yet. Questions are reviewed before publication.
Every characteristic recorded for MQ-4B, with where it comes from. Use the filters to find one quickly.
| Characteristic | Value |
|---|---|
| Characteristics | High sensitivity to CH4 and strong anti-interference ability |
| Detection Principle | Semiconductor |
| Detection range | 300-10000ppm |
| Life span | 10 years |
| Model | MQ-4B |
| Sensor character under standard test conditions | 28Ω ±3Ω (room temp.) |
| Sensor Type | Semiconductor |
| Size | φ16.7×9.4 |
| Standard Circuit; Conditions | 5.0V±0.1VDC |
| Standard Encapsulation | Plastic |
| Standard test conditions | 20℃±2℃;55%±5%RH |
| Target | methane CH4, natural gas, flammable gas |
| Target gas | Methane |
| Working Conditions | Loop Voltage:5±0.1V; Heater Voltage:5±0.1V; Heater consumption:≤1W |
No specification matches.
Last verification : 2026-11-02
Official documents and the technical data recorded for MQ-4B. For a missing document or a specific revision, our experts send it to you.
Winsen MQ-4B MOS semiconductor sensor for detecting methane CH4, natural gas and flammable gases, for leak alarms and portable gas detectors.
| Parameter | Value |
|---|---|
| Characteristics | High sensitivity to CH4 and strong anti-interference ability |
| Detection Principle | Semiconductor |
| Detection range | 300-10000ppm |
| Life span | 10 years |
| Model | MQ-4B |
| Sensor character under standard test conditions | 28Ω ±3Ω (room temp.) |
| Sensor Type | Semiconductor |
| Size | φ16.7×9.4 |
| Standard Circuit; Conditions | 5.0V±0.1VDC |
| Standard Encapsulation | Plastic |
| Standard test conditions | 20℃±2℃;55%±5%RH |
| Target | methane CH4, natural gas, flammable gas |
| Target gas | Methane |
| Working Conditions | Loop Voltage:5±0.1V; Heater Voltage:5±0.1V; Heater consumption:≤1W |
Similar parts to answer your needs. Compare the main characteristics. A recorded replacement is a documented relation; a similar product is a similarity only, never a compatibility claim.
Flammable gas MOS sensor for methane CH4

MOS Flammable Gas Sensor for Methane CH4 Detector

Methane CH4 Natural Gas Sensor

MOS Combustible Gas Sensor Detect Propane LPG Methane

Describe your application and constraints in a request.
What is recorded about the regulatory status and the life of this part.
No compliance statement is recorded for this part. Ask the supplier for the RoHS and REACH declarations and, for a radio product, the EU declaration of conformity.
| Current status | Status not stated |
| Key dates | Not recorded |
| Manufacturer part number | MQ-4B |
| Manufacturer | Winsen |
Methane Sensors
Natural gas (methane) detector with CAN Bus interface · Ref. : CL-20A-C
Price on request
Methane Sensors
MEMS combustible methane gas sensor · Ref. : RS-CH01
Price on request
Methane Sensors
MEMS methane CH4 gas detection sensor (breakout) · Ref. : SEN0565
Price on request
Methane Sensors
Flammable gas MOS sensor for propane, LPG and methane · Ref. : MQ-5B
Price on request
With your consent, we use Google cookies to measure the site’s audience and our advertising. Your quote basket and comparison stay in your browser either way. Details